<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://neurophys.org/wiki/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Bpw</id>
	<title>NeurophysPedia - User contributions [en]</title>
	<link rel="self" type="application/atom+xml" href="https://neurophys.org/wiki/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Bpw"/>
	<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/Special:Contributions/Bpw"/>
	<updated>2026-05-01T15:50:32Z</updated>
	<subtitle>User contributions</subtitle>
	<generator>MediaWiki 1.40.1</generator>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=General_Information&amp;diff=587</id>
		<title>General Information</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=General_Information&amp;diff=587"/>
		<updated>2022-08-17T14:21:47Z</updated>

		<summary type="html">&lt;p&gt;Bpw: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Introduction==&lt;br /&gt;
&lt;br /&gt;
==Organizations==&lt;br /&gt;
&lt;br /&gt;
#[http://www.asnm.org American Society of Neurophysiological Monitoring]&lt;br /&gt;
#[http://www.acns.org American Clinical Neurophysiology Society]&lt;br /&gt;
#[http://www.aset.org The Neurodiagnostic Society (ASET)]&lt;br /&gt;
#[http://abnm.info American Board of Neurophysiologic Monitoring]&lt;br /&gt;
#[http://www.neurophysiology.org International Society of Intraoperative Neurophysiology (ISIN)]&lt;br /&gt;
#[http://www.ifcn.info International Federation of Clinical Neurophysiology]&lt;br /&gt;
#[http://www.aan.com  American Academy of Neurology]&lt;br /&gt;
#[http://www.oegkn.at/translat.htm Austrian Society for Clinical Neurophysiology]&lt;br /&gt;
#[http://www.neurofisiologia.net Italian Neurophysiological Technologists]&lt;br /&gt;
#[http://www.smnfc.com  Mexican Clinical Neurophysiology Society] Represents all certified clinical neurophysiologists in Mexico, with local and global event information in Spanish.&lt;br /&gt;
&lt;br /&gt;
==Conferences==&lt;br /&gt;
&lt;br /&gt;
#[https://www.asnm.org/2022-fall-virtual-meeting ASNM 2022 Fall Virtual Symposium] September 24, 2022&lt;br /&gt;
#[https://neurophysiology.org/isin-events/ ISIN 2022] October 31 – November 5, 2022, Chicago, USA&lt;br /&gt;
&lt;br /&gt;
==Past Conferences==&lt;br /&gt;
&lt;br /&gt;
#[http://isin2019vienna.org 7th Congress of the International Society of Intraoperative Neurophysiology] October 28 - November 2, 2019, Vienna, Austria.&lt;br /&gt;
#[http://www.asnm.org/resource/resmgr/Events/2018/Annual/2018_Annual_Agenda.pdf ASNM Annual Meeting] February 23-25, 2018 - Lake Buena Vista, Florida&lt;br /&gt;
#[http://iccn2018.acns.org/ 31st International Congress of Clinical Neurophysiology of the IFCN] May 1 -6, 2018, Washington DC, United States&lt;br /&gt;
#[https://www.aset.org/i4a/pages/index.cfm?pageid=3289 The ASET 2018 Annual Conference] August 16 - 18, 2018, New Orleans&lt;br /&gt;
#[http://www.asnm.org/events/EventDetails.aspx?id=1091780 ASNM Fall Symposium] September 15-16, 2018 - Nashville, Tennessee&lt;br /&gt;
#[http://www.acns.org/meetings/fall-courses/2017-fall-courses American Clinical Neurophysiology Society Fall Courses] October 14-15, 2018 - Chicago, Illinois.&lt;br /&gt;
&lt;br /&gt;
==Books==&lt;br /&gt;
#[http://www.amazon.com/Intraoperative-Neurophysiology-Mirela-Simon-MD-ebook/dp/B004MME2HY/tag=clinicalneurophy Intraoperative Neurophysiology] by Mirela Simon&lt;br /&gt;
#[http://www.amazon.com/Neurophysiology-Neurosurgery-Modern-Intraoperative-Approach/dp/0122090365/tag=clinicalneurophy Neurophysiology in Neurosurgery: A Modern Intraoperative Approach] by  Vedran Deletis and Jay Shils&lt;br /&gt;
#[http://www.amazon.com/Intraoperative-Neurophysiological-Monitoring-Aage-Møller/dp/1588297039/tag=clinicalneurophy Intraoperative Neurophysiological Monitoring] by Aage R. Møller&lt;br /&gt;
#[http://www.amazon.com/Intraoperative-Monitoring-Neural-Function-Neurophysiology/dp/044451824X/tag=clinicalneurophy Intraoperative Monitoring of Neural Function: Handbook of Clinical Neurophysiology] by  Marc R. Nuwer&lt;br /&gt;
&lt;br /&gt;
==Journals==&lt;br /&gt;
&lt;br /&gt;
#[http://journals.lww.com/clinicalneurophys/pages/default.aspx  Journal of Clinical Neurophysiology] Official Journal of the American Clinical Neurophysiology Society.&lt;br /&gt;
#[http://www.journals.elsevier.com/clinical-neurophysiology Clinical Neurophysiology] The official journal of the International Federation of Clinical Neurophysiology. It is dedicated to fostering research and disseminating information on all aspects of Clinical Neurophysiology.&lt;br /&gt;
#[http://www.the-aps.org/mm/Publications/Journals/JN Journal of Neurophysiology] publishes original articles on the function of the nervous system, from American Physiological Society.&lt;br /&gt;
#[http://onlinelibrary.wiley.com/journal/10.1002/%28ISSN%291097-4598 Muscle &amp;amp; Nerve] Journal of American Association of Neuromuscular &amp;amp; Electrodiagnostic Medicine.&lt;br /&gt;
#[http://thejns.org/ Journal of Neurosurgery]&lt;br /&gt;
#[http://www.jneurosci.org/  The Journal of Neuroscience] published by Society for Neuroscience.&lt;br /&gt;
&lt;br /&gt;
==Web discussion forums==&lt;br /&gt;
&lt;br /&gt;
==Mailing lists==&lt;br /&gt;
#The Neuromonitoring mailing list - is for anyone with a professional or scientific interest in neuromonitoring. To subscribe, send email to listproc@usc.edu with the following request &amp;quot;subscribe NEUROMON-L Your Name&amp;quot;.&lt;br /&gt;
#[http://home.ease.lsoft.com/scripts/wa-HOME.exe?A0=EPILEPSY-L  EPILEPSY-L: Epilepsy support group] is an email based support group (discussion list) for people with epilepsy and those who care about and for them.&lt;br /&gt;
&lt;br /&gt;
==Study resources==&lt;br /&gt;
&lt;br /&gt;
#[http://www.ptcny.com/clients/ABNM/ABNM.html  Certification Examination in Neurophysiologic Monitoring] ABNM Board exam by American Board of Neurophysiologic Monitoring&lt;br /&gt;
#[http://www.ptcny.com/clients/ABRET/#Certification%20Examination%20in%20Neurophysiologic%20Intraoperative%20Monitoring Certification Examination in Neurophysiologic Intraoperative Monitoring] ABRET-CNIM by American Board of Registration of Electroencephalographic and Evoked Potential Technologists.&lt;br /&gt;
#[http://larryheadinstituteonline.com/lh/courses/ionm-training/ IONM Training] at Larry Head Institute&lt;br /&gt;
&lt;br /&gt;
==Jobs==&lt;br /&gt;
&lt;br /&gt;
#[http://www.asnm.org/?page=Careers Job postings] for ASNM memebers&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=General_Information&amp;diff=586</id>
		<title>General Information</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=General_Information&amp;diff=586"/>
		<updated>2022-08-17T14:17:06Z</updated>

		<summary type="html">&lt;p&gt;Bpw: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Introduction==&lt;br /&gt;
&lt;br /&gt;
==Organizations==&lt;br /&gt;
&lt;br /&gt;
#[http://www.asnm.org American Society of Neurophysiological Monitoring]&lt;br /&gt;
#[http://www.acns.org American Clinical Neurophysiology Society]&lt;br /&gt;
#[http://www.aset.org The Neurodiagnostic Society (ASET)]&lt;br /&gt;
#[http://abnm.info American Board of Neurophysiologic Monitoring]&lt;br /&gt;
#[http://www.neurophysiology.org International Society of Intraoperative Neurophysiology (ISIN)]&lt;br /&gt;
#[http://www.ifcn.info International Federation of Clinical Neurophysiology]&lt;br /&gt;
#[http://www.aan.com  American Academy of Neurology]&lt;br /&gt;
#[http://www.oegkn.at/translat.htm Austrian Society for Clinical Neurophysiology]&lt;br /&gt;
#[http://www.neurofisiologia.net Italian Neurophysiological Technologists]&lt;br /&gt;
#[http://www.smnfc.com  Mexican Clinical Neurophysiology Society] Represents all certified clinical neurophysiologists in Mexico, with local and global event information in Spanish.&lt;br /&gt;
&lt;br /&gt;
==Conferences==&lt;br /&gt;
&lt;br /&gt;
#[https://www.asnm.org/2022-fall-virtual-meeting ASNM 2022 Fall Virtual Symposium] September 24, 2022&lt;br /&gt;
&lt;br /&gt;
==Past Conferences==&lt;br /&gt;
&lt;br /&gt;
#[http://isin2019vienna.org 7th Congress of the International Society of Intraoperative Neurophysiology] October 28 - November 2, 2019, Vienna, Austria.&lt;br /&gt;
#[http://www.asnm.org/resource/resmgr/Events/2018/Annual/2018_Annual_Agenda.pdf ASNM Annual Meeting] February 23-25, 2018 - Lake Buena Vista, Florida&lt;br /&gt;
#[http://iccn2018.acns.org/ 31st International Congress of Clinical Neurophysiology of the IFCN] May 1 -6, 2018, Washington DC, United States&lt;br /&gt;
#[https://www.aset.org/i4a/pages/index.cfm?pageid=3289 The ASET 2018 Annual Conference] August 16 - 18, 2018, New Orleans&lt;br /&gt;
#[http://www.asnm.org/events/EventDetails.aspx?id=1091780 ASNM Fall Symposium] September 15-16, 2018 - Nashville, Tennessee&lt;br /&gt;
#[http://www.acns.org/meetings/fall-courses/2017-fall-courses American Clinical Neurophysiology Society Fall Courses] October 14-15, 2018 - Chicago, Illinois.&lt;br /&gt;
&lt;br /&gt;
==Books==&lt;br /&gt;
#[http://www.amazon.com/Intraoperative-Neurophysiology-Mirela-Simon-MD-ebook/dp/B004MME2HY/tag=clinicalneurophy Intraoperative Neurophysiology] by Mirela Simon&lt;br /&gt;
#[http://www.amazon.com/Neurophysiology-Neurosurgery-Modern-Intraoperative-Approach/dp/0122090365/tag=clinicalneurophy Neurophysiology in Neurosurgery: A Modern Intraoperative Approach] by  Vedran Deletis and Jay Shils&lt;br /&gt;
#[http://www.amazon.com/Intraoperative-Neurophysiological-Monitoring-Aage-Møller/dp/1588297039/tag=clinicalneurophy Intraoperative Neurophysiological Monitoring] by Aage R. Møller&lt;br /&gt;
#[http://www.amazon.com/Intraoperative-Monitoring-Neural-Function-Neurophysiology/dp/044451824X/tag=clinicalneurophy Intraoperative Monitoring of Neural Function: Handbook of Clinical Neurophysiology] by  Marc R. Nuwer&lt;br /&gt;
&lt;br /&gt;
==Journals==&lt;br /&gt;
&lt;br /&gt;
#[http://journals.lww.com/clinicalneurophys/pages/default.aspx  Journal of Clinical Neurophysiology] Official Journal of the American Clinical Neurophysiology Society.&lt;br /&gt;
#[http://www.journals.elsevier.com/clinical-neurophysiology Clinical Neurophysiology] The official journal of the International Federation of Clinical Neurophysiology. It is dedicated to fostering research and disseminating information on all aspects of Clinical Neurophysiology.&lt;br /&gt;
#[http://www.the-aps.org/mm/Publications/Journals/JN Journal of Neurophysiology] publishes original articles on the function of the nervous system, from American Physiological Society.&lt;br /&gt;
#[http://onlinelibrary.wiley.com/journal/10.1002/%28ISSN%291097-4598 Muscle &amp;amp; Nerve] Journal of American Association of Neuromuscular &amp;amp; Electrodiagnostic Medicine.&lt;br /&gt;
#[http://thejns.org/ Journal of Neurosurgery]&lt;br /&gt;
#[http://www.jneurosci.org/  The Journal of Neuroscience] published by Society for Neuroscience.&lt;br /&gt;
&lt;br /&gt;
==Web discussion forums==&lt;br /&gt;
&lt;br /&gt;
==Mailing lists==&lt;br /&gt;
#The Neuromonitoring mailing list - is for anyone with a professional or scientific interest in neuromonitoring. To subscribe, send email to listproc@usc.edu with the following request &amp;quot;subscribe NEUROMON-L Your Name&amp;quot;.&lt;br /&gt;
#[http://home.ease.lsoft.com/scripts/wa-HOME.exe?A0=EPILEPSY-L  EPILEPSY-L: Epilepsy support group] is an email based support group (discussion list) for people with epilepsy and those who care about and for them.&lt;br /&gt;
&lt;br /&gt;
==Study resources==&lt;br /&gt;
&lt;br /&gt;
#[http://www.ptcny.com/clients/ABNM/ABNM.html  Certification Examination in Neurophysiologic Monitoring] ABNM Board exam by American Board of Neurophysiologic Monitoring&lt;br /&gt;
#[http://www.ptcny.com/clients/ABRET/#Certification%20Examination%20in%20Neurophysiologic%20Intraoperative%20Monitoring Certification Examination in Neurophysiologic Intraoperative Monitoring] ABRET-CNIM by American Board of Registration of Electroencephalographic and Evoked Potential Technologists.&lt;br /&gt;
#[http://larryheadinstituteonline.com/lh/courses/ionm-training/ IONM Training] at Larry Head Institute&lt;br /&gt;
&lt;br /&gt;
==Jobs==&lt;br /&gt;
&lt;br /&gt;
#[http://www.asnm.org/?page=Careers Job postings] for ASNM memebers&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=Main_Page&amp;diff=553</id>
		<title>Main Page</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=Main_Page&amp;diff=553"/>
		<updated>2021-12-22T22:04:06Z</updated>

		<summary type="html">&lt;p&gt;Bpw: /* Neurophyspedia : Intraoperative Neurophysiology */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
&lt;br /&gt;
= [[Neurophyspedia : Intraoperative Neurophysiology]] =&lt;br /&gt;
&lt;br /&gt;
Welcome to Neurophyspedia, the Wikipedia for Intraoperative Neurophysiology.&lt;br /&gt;
&lt;br /&gt;
== [[General Information]]==&lt;br /&gt;
&lt;br /&gt;
== [[Basic Neurophysiology]]  ==&lt;br /&gt;
&lt;br /&gt;
== [[Somatosensory Evoked Potentials (SSEP)]] ==&lt;br /&gt;
&lt;br /&gt;
== [[Motor Evoked Potentials (MEP)]] ==&lt;br /&gt;
&lt;br /&gt;
== [[Brainstem Auditory Evoked Responses (BAER)]] ==&lt;br /&gt;
&lt;br /&gt;
== [[Visual Evoked Potentials (VEP)]] ==&lt;br /&gt;
&lt;br /&gt;
== [[Electroencephalography (EEG)]] ==&lt;br /&gt;
&lt;br /&gt;
== [[Electromyography (EMG)]] ==&lt;br /&gt;
&lt;br /&gt;
== [[Intraoperative Neurophysiological Monitoring (IONM)]] ==&lt;br /&gt;
&lt;br /&gt;
== [[IONM in Cranial Surgery]] ==&lt;br /&gt;
&lt;br /&gt;
== [[IONM in Spinal Surgery]]==&lt;br /&gt;
&lt;br /&gt;
== [[IONM in Peripheral Nerve Surgery]]==&lt;br /&gt;
&lt;br /&gt;
== [[IONM in Vascular Surgery]]==&lt;br /&gt;
&lt;br /&gt;
== [[IONM in Otolaryngological or ENT Surgery]]==&lt;br /&gt;
 &lt;br /&gt;
== [[Neurophysiological Diagnostics]] ==&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=General_Information&amp;diff=552</id>
		<title>General Information</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=General_Information&amp;diff=552"/>
		<updated>2021-12-22T22:02:47Z</updated>

		<summary type="html">&lt;p&gt;Bpw: /* Conferences */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Introduction==&lt;br /&gt;
&lt;br /&gt;
==Organizations==&lt;br /&gt;
&lt;br /&gt;
#[http://www.asnm.org American Society of Neurophysiological Monitoring]&lt;br /&gt;
#[http://www.acns.org American Clinical Neurophysiology Society]&lt;br /&gt;
#[http://www.aset.org The Neurodiagnostic Society (ASET)]&lt;br /&gt;
#[http://abnm.info American Board of Neurophysiologic Monitoring]&lt;br /&gt;
#[http://www.neurophysiology.org International Society of Intraoperative Neurophysiology (ISIN)]&lt;br /&gt;
#[http://www.ifcn.info International Federation of Clinical Neurophysiology]&lt;br /&gt;
#[http://www.aan.com  American Academy of Neurology]&lt;br /&gt;
#[http://www.oegkn.at/translat.htm Austrian Society for Clinical Neurophysiology]&lt;br /&gt;
#[http://www.neurofisiologia.net Italian Neurophysiological Technologists]&lt;br /&gt;
#[http://www.smnfc.com  Mexican Clinical Neurophysiology Society] Represents all certified clinical neurophysiologists in Mexico, with local and global event information in Spanish.&lt;br /&gt;
&lt;br /&gt;
==Conferences==&lt;br /&gt;
&lt;br /&gt;
#[http://isin2019vienna.org 7th Congress of the International Society of Intraoperative Neurophysiology] October 28 - November 2, 2019, Vienna, Austria.&lt;br /&gt;
#[http://www.asnm.org/resource/resmgr/Events/2018/Annual/2018_Annual_Agenda.pdf ASNM Annual Meeting] February 23-25, 2018 - Lake Buena Vista, Florida&lt;br /&gt;
#[http://iccn2018.acns.org/ 31st International Congress of Clinical Neurophysiology of the IFCN] May 1 -6, 2018, Washington DC, United States&lt;br /&gt;
#[https://www.aset.org/i4a/pages/index.cfm?pageid=3289 The ASET 2018 Annual Conference] August 16 - 18, 2018, New Orleans&lt;br /&gt;
#[http://www.asnm.org/events/EventDetails.aspx?id=1091780 ASNM Fall Symposium] September 15-16, 2018 - Nashville, Tennessee&lt;br /&gt;
#[http://www.acns.org/meetings/fall-courses/2017-fall-courses American Clinical Neurophysiology Society Fall Courses] October 14-15, 2018 - Chicago, Illinois.&lt;br /&gt;
&lt;br /&gt;
==Books==&lt;br /&gt;
#[http://www.amazon.com/Intraoperative-Neurophysiology-Mirela-Simon-MD-ebook/dp/B004MME2HY/tag=clinicalneurophy Intraoperative Neurophysiology] by Mirela Simon&lt;br /&gt;
#[http://www.amazon.com/Neurophysiology-Neurosurgery-Modern-Intraoperative-Approach/dp/0122090365/tag=clinicalneurophy Neurophysiology in Neurosurgery: A Modern Intraoperative Approach] by  Vedran Deletis and Jay Shils&lt;br /&gt;
#[http://www.amazon.com/Intraoperative-Neurophysiological-Monitoring-Aage-Møller/dp/1588297039/tag=clinicalneurophy Intraoperative Neurophysiological Monitoring] by Aage R. Møller&lt;br /&gt;
#[http://www.amazon.com/Intraoperative-Monitoring-Neural-Function-Neurophysiology/dp/044451824X/tag=clinicalneurophy Intraoperative Monitoring of Neural Function: Handbook of Clinical Neurophysiology] by  Marc R. Nuwer&lt;br /&gt;
&lt;br /&gt;
==Journals==&lt;br /&gt;
&lt;br /&gt;
#[http://journals.lww.com/clinicalneurophys/pages/default.aspx  Journal of Clinical Neurophysiology] Official Journal of the American Clinical Neurophysiology Society.&lt;br /&gt;
#[http://www.journals.elsevier.com/clinical-neurophysiology Clinical Neurophysiology] The official journal of the International Federation of Clinical Neurophysiology. It is dedicated to fostering research and disseminating information on all aspects of Clinical Neurophysiology.&lt;br /&gt;
#[http://www.the-aps.org/mm/Publications/Journals/JN Journal of Neurophysiology] publishes original articles on the function of the nervous system, from American Physiological Society.&lt;br /&gt;
#[http://onlinelibrary.wiley.com/journal/10.1002/%28ISSN%291097-4598 Muscle &amp;amp; Nerve] Journal of American Association of Neuromuscular &amp;amp; Electrodiagnostic Medicine.&lt;br /&gt;
#[http://thejns.org/ Journal of Neurosurgery]&lt;br /&gt;
#[http://www.jneurosci.org/  The Journal of Neuroscience] published by Society for Neuroscience.&lt;br /&gt;
&lt;br /&gt;
==Web discussion forums==&lt;br /&gt;
&lt;br /&gt;
==Mailing lists==&lt;br /&gt;
#The Neuromonitoring mailing list - is for anyone with a professional or scientific interest in neuromonitoring. To subscribe, send email to listproc@usc.edu with the following request &amp;quot;subscribe NEUROMON-L Your Name&amp;quot;.&lt;br /&gt;
#[http://home.ease.lsoft.com/scripts/wa-HOME.exe?A0=EPILEPSY-L  EPILEPSY-L: Epilepsy support group] is an email based support group (discussion list) for people with epilepsy and those who care about and for them.&lt;br /&gt;
&lt;br /&gt;
==Study resources==&lt;br /&gt;
&lt;br /&gt;
#[http://www.ptcny.com/clients/ABNM/ABNM.html  Certification Examination in Neurophysiologic Monitoring] ABNM Board exam by American Board of Neurophysiologic Monitoring&lt;br /&gt;
#[http://www.ptcny.com/clients/ABRET/#Certification%20Examination%20in%20Neurophysiologic%20Intraoperative%20Monitoring Certification Examination in Neurophysiologic Intraoperative Monitoring] ABRET-CNIM by American Board of Registration of Electroencephalographic and Evoked Potential Technologists.&lt;br /&gt;
#[http://larryheadinstituteonline.com/lh/courses/ionm-training/ IONM Training] at Larry Head Institute&lt;br /&gt;
&lt;br /&gt;
==Jobs==&lt;br /&gt;
&lt;br /&gt;
#[http://www.asnm.org/?page=Careers Job postings] for ASNM memebers&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=Main_Page&amp;diff=551</id>
		<title>Main Page</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=Main_Page&amp;diff=551"/>
		<updated>2021-12-22T22:02:08Z</updated>

		<summary type="html">&lt;p&gt;Bpw: /* Neurophyspedia : Intraoperative Neurophysiology */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
&lt;br /&gt;
= [[Neurophyspedia : Intraoperative Neurophysiology]] =&lt;br /&gt;
&lt;br /&gt;
Welcome to Neurophyspedia, the Wikipedia for Intraoperative Neurophysiology&lt;br /&gt;
&lt;br /&gt;
== [[General Information]]==&lt;br /&gt;
&lt;br /&gt;
== [[Basic Neurophysiology]]  ==&lt;br /&gt;
&lt;br /&gt;
== [[Somatosensory Evoked Potentials (SSEP)]] ==&lt;br /&gt;
&lt;br /&gt;
== [[Motor Evoked Potentials (MEP)]] ==&lt;br /&gt;
&lt;br /&gt;
== [[Brainstem Auditory Evoked Responses (BAER)]] ==&lt;br /&gt;
&lt;br /&gt;
== [[Visual Evoked Potentials (VEP)]] ==&lt;br /&gt;
&lt;br /&gt;
== [[Electroencephalography (EEG)]] ==&lt;br /&gt;
&lt;br /&gt;
== [[Electromyography (EMG)]] ==&lt;br /&gt;
&lt;br /&gt;
== [[Intraoperative Neurophysiological Monitoring (IONM)]] ==&lt;br /&gt;
&lt;br /&gt;
== [[IONM in Cranial Surgery]] ==&lt;br /&gt;
&lt;br /&gt;
== [[IONM in Spinal Surgery]]==&lt;br /&gt;
&lt;br /&gt;
== [[IONM in Peripheral Nerve Surgery]]==&lt;br /&gt;
&lt;br /&gt;
== [[IONM in Vascular Surgery]]==&lt;br /&gt;
&lt;br /&gt;
== [[IONM in Otolaryngological or ENT Surgery]]==&lt;br /&gt;
 &lt;br /&gt;
== [[Neurophysiological Diagnostics]] ==&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=Main_Page&amp;diff=359</id>
		<title>Main Page</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=Main_Page&amp;diff=359"/>
		<updated>2019-10-31T07:21:21Z</updated>

		<summary type="html">&lt;p&gt;Bpw: /* Neurophyspedia : Intraoperative Neurophysiology */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
&lt;br /&gt;
= [[Neurophyspedia : Intraoperative Neurophysiology]] =&lt;br /&gt;
&lt;br /&gt;
Welcome to Neurophyspedia, the Wikipedia for Intraoperative Neurophysiology.&lt;br /&gt;
&lt;br /&gt;
== [[General Information]]==&lt;br /&gt;
&lt;br /&gt;
== [[Basic Neurophysiology]]  ==&lt;br /&gt;
&lt;br /&gt;
== [[Somatosensory Evoked Potentials (SSEP)]] ==&lt;br /&gt;
&lt;br /&gt;
== [[Motor Evoked Potentials (MEP)]] ==&lt;br /&gt;
&lt;br /&gt;
== [[Brainstem Auditory Evoked Responses (BAER)]] ==&lt;br /&gt;
&lt;br /&gt;
== [[Visual Evoked Potentials (VEP)]] ==&lt;br /&gt;
&lt;br /&gt;
== [[Electroencephalography (EEG)]] ==&lt;br /&gt;
&lt;br /&gt;
== [[Electromyography (EMG)]] ==&lt;br /&gt;
&lt;br /&gt;
== [[Intraoperative Neurophysiological Monitoring (IONM)]] ==&lt;br /&gt;
&lt;br /&gt;
== [[IONM in Cranial Surgery]] ==&lt;br /&gt;
&lt;br /&gt;
== [[IONM in Spinal Surgery]]==&lt;br /&gt;
&lt;br /&gt;
== [[IONM in Peripheral Nerve Surgery]]==&lt;br /&gt;
&lt;br /&gt;
== [[IONM in Vascular Surgery]]==&lt;br /&gt;
&lt;br /&gt;
== [[IONM in Otolaryngological or ENT Surgery]]==&lt;br /&gt;
 &lt;br /&gt;
== [[Neurophysiological Diagnostics]] ==&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=General_Information&amp;diff=358</id>
		<title>General Information</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=General_Information&amp;diff=358"/>
		<updated>2019-10-31T07:19:21Z</updated>

		<summary type="html">&lt;p&gt;Bpw: /* Conferences */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Introduction==&lt;br /&gt;
&lt;br /&gt;
==Organizations==&lt;br /&gt;
&lt;br /&gt;
#[http://www.asnm.org American Society of Neurophysiological Monitoring]&lt;br /&gt;
#[http://www.acns.org American Clinical Neurophysiology Society]&lt;br /&gt;
#[http://www.aset.org The Neurodiagnostic Society (ASET)]&lt;br /&gt;
#[http://abnm.info American Board of Neurophysiologic Monitoring]&lt;br /&gt;
#[http://www.neurophysiology.org International Society of Intraoperative Neurophysiology (ISIN)]&lt;br /&gt;
#[http://www.ifcn.info International Federation of Clinical Neurophysiology]&lt;br /&gt;
#[http://www.aan.com  American Academy of Neurology]&lt;br /&gt;
#[http://www.oegkn.at/translat.htm Austrian Society for Clinical Neurophysiology]&lt;br /&gt;
#[http://www.neurofisiologia.net Italian Neurophysiological Technologists]&lt;br /&gt;
#[http://www.smnfc.com  Mexican Clinical Neurophysiology Society] Represents all certified clinical neurophysiologists in Mexico, with local and global event information in Spanish.&lt;br /&gt;
&lt;br /&gt;
==Conferences==&lt;br /&gt;
&lt;br /&gt;
#[http://isin2019vienna.org 7th Congress of the International Society of Intraoperative Neurophysiology] October 28 - November 2, 2019, Vienna, Austria &lt;br /&gt;
#[http://www.asnm.org/resource/resmgr/Events/2018/Annual/2018_Annual_Agenda.pdf ASNM Annual Meeting] February 23-25, 2018 - Lake Buena Vista, Florida&lt;br /&gt;
#[http://iccn2018.acns.org/ 31st International Congress of Clinical Neurophysiology of the IFCN] May 1 -6, 2018, Washington DC, United States&lt;br /&gt;
#[https://www.aset.org/i4a/pages/index.cfm?pageid=3289 The ASET 2018 Annual Conference] August 16 - 18, 2018, New Orleans&lt;br /&gt;
#[http://www.asnm.org/events/EventDetails.aspx?id=1091780 ASNM Fall Symposium] September 15-16, 2018 - Nashville, Tennessee&lt;br /&gt;
#[http://www.acns.org/meetings/fall-courses/2017-fall-courses American Clinical Neurophysiology Society Fall Courses] October 14-15, 2018 - Chicago, Illinois.&lt;br /&gt;
&lt;br /&gt;
==Books==&lt;br /&gt;
#[http://www.amazon.com/Intraoperative-Neurophysiology-Mirela-Simon-MD-ebook/dp/B004MME2HY/tag=clinicalneurophy Intraoperative Neurophysiology] by Mirela Simon&lt;br /&gt;
#[http://www.amazon.com/Neurophysiology-Neurosurgery-Modern-Intraoperative-Approach/dp/0122090365/tag=clinicalneurophy Neurophysiology in Neurosurgery: A Modern Intraoperative Approach] by  Vedran Deletis and Jay Shils&lt;br /&gt;
#[http://www.amazon.com/Intraoperative-Neurophysiological-Monitoring-Aage-Møller/dp/1588297039/tag=clinicalneurophy Intraoperative Neurophysiological Monitoring] by Aage R. Møller&lt;br /&gt;
#[http://www.amazon.com/Intraoperative-Monitoring-Neural-Function-Neurophysiology/dp/044451824X/tag=clinicalneurophy Intraoperative Monitoring of Neural Function: Handbook of Clinical Neurophysiology] by  Marc R. Nuwer&lt;br /&gt;
&lt;br /&gt;
==Journals==&lt;br /&gt;
&lt;br /&gt;
#[http://journals.lww.com/clinicalneurophys/pages/default.aspx  Journal of Clinical Neurophysiology] Official Journal of the American Clinical Neurophysiology Society.&lt;br /&gt;
#[http://www.journals.elsevier.com/clinical-neurophysiology Clinical Neurophysiology] The official journal of the International Federation of Clinical Neurophysiology. It is dedicated to fostering research and disseminating information on all aspects of Clinical Neurophysiology.&lt;br /&gt;
#[http://www.the-aps.org/mm/Publications/Journals/JN Journal of Neurophysiology] publishes original articles on the function of the nervous system, from American Physiological Society.&lt;br /&gt;
#[http://onlinelibrary.wiley.com/journal/10.1002/%28ISSN%291097-4598 Muscle &amp;amp; Nerve] Journal of American Association of Neuromuscular &amp;amp; Electrodiagnostic Medicine.&lt;br /&gt;
#[http://thejns.org/ Journal of Neurosurgery]&lt;br /&gt;
#[http://www.jneurosci.org/  The Journal of Neuroscience] published by Society for Neuroscience.&lt;br /&gt;
&lt;br /&gt;
==Web discussion forums==&lt;br /&gt;
&lt;br /&gt;
==Mailing lists==&lt;br /&gt;
#The Neuromonitoring mailing list - is for anyone with a professional or scientific interest in neuromonitoring. To subscribe, send email to listproc@usc.edu with the following request &amp;quot;subscribe NEUROMON-L Your Name&amp;quot;.&lt;br /&gt;
#[http://home.ease.lsoft.com/scripts/wa-HOME.exe?A0=EPILEPSY-L  EPILEPSY-L: Epilepsy support group] is an email based support group (discussion list) for people with epilepsy and those who care about and for them.&lt;br /&gt;
&lt;br /&gt;
==Study resources==&lt;br /&gt;
&lt;br /&gt;
#[http://www.ptcny.com/clients/ABNM/ABNM.html  Certification Examination in Neurophysiologic Monitoring] ABNM Board exam by American Board of Neurophysiologic Monitoring&lt;br /&gt;
#[http://www.ptcny.com/clients/ABRET/#Certification%20Examination%20in%20Neurophysiologic%20Intraoperative%20Monitoring Certification Examination in Neurophysiologic Intraoperative Monitoring] ABRET-CNIM by American Board of Registration of Electroencephalographic and Evoked Potential Technologists.&lt;br /&gt;
#[http://larryheadinstituteonline.com/lh/courses/ionm-training/ IONM Training] at Larry Head Institute&lt;br /&gt;
&lt;br /&gt;
==Jobs==&lt;br /&gt;
&lt;br /&gt;
#[http://www.asnm.org/?page=Careers Job postings] for ASNM memebers&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=General_Information&amp;diff=197</id>
		<title>General Information</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=General_Information&amp;diff=197"/>
		<updated>2018-04-12T16:54:18Z</updated>

		<summary type="html">&lt;p&gt;Bpw: /* Conferences */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Introduction==&lt;br /&gt;
&lt;br /&gt;
==Organizations==&lt;br /&gt;
&lt;br /&gt;
#[http://www.asnm.org American Society of Neurophysiological Monitoring]&lt;br /&gt;
#[http://www.acns.org American Clinical Neurophysiology Society]&lt;br /&gt;
#[http://www.aset.org The Neurodiagnostic Society (ASET)]&lt;br /&gt;
#[http://abnm.info American Board of Neurophysiologic Monitoring]&lt;br /&gt;
#[http://www.neurophysiology.org International Society of Intraoperative Neurophysiology (ISIN)]&lt;br /&gt;
#[http://www.ifcn.info International Federation of Clinical Neurophysiology]&lt;br /&gt;
#[http://www.aan.com  American Academy of Neurology]&lt;br /&gt;
#[http://www.oegkn.at/translat.htm Austrian Society for Clinical Neurophysiology]&lt;br /&gt;
#[http://www.neurofisiologia.net Italian Neurophysiological Technologists]&lt;br /&gt;
#[http://www.smnfc.com  Mexican Clinical Neurophysiology Society] Represents all certified clinical neurophysiologists in Mexico, with local and global event information in Spanish.&lt;br /&gt;
&lt;br /&gt;
==Conferences==&lt;br /&gt;
&lt;br /&gt;
#[http://www.asnm.org/resource/resmgr/Events/2018/Annual/2018_Annual_Agenda.pdf ASNM Annual Meeting] February 23-25, 2018 - Lake Buena Vista, Florida&lt;br /&gt;
#[http://iccn2018.acns.org/ 31st International Congress of Clinical Neurophysiology of the IFCN] May 1 -6, 2018, Washington DC, United States&lt;br /&gt;
#[https://www.aset.org/i4a/pages/index.cfm?pageid=3289 The ASET 2018 Annual Conference] August 16 - 18, 2018, New Orleans&lt;br /&gt;
#[http://www.asnm.org/events/EventDetails.aspx?id=1091780 ASNM Fall Symposium] September 15-16, 2018 - Nashville, Tennessee&lt;br /&gt;
#[http://www.acns.org/meetings/fall-courses/2017-fall-courses American Clinical Neurophysiology Society Fall Courses] October 14-15, 2018 - Chicago, Illinois.&lt;br /&gt;
&lt;br /&gt;
==Books==&lt;br /&gt;
#[http://www.amazon.com/Intraoperative-Neurophysiology-Mirela-Simon-MD-ebook/dp/B004MME2HY/tag=clinicalneurophy Intraoperative Neurophysiology] by Mirela Simon&lt;br /&gt;
#[http://www.amazon.com/Neurophysiology-Neurosurgery-Modern-Intraoperative-Approach/dp/0122090365/tag=clinicalneurophy Neurophysiology in Neurosurgery: A Modern Intraoperative Approach] by  Vedran Deletis and Jay Shils&lt;br /&gt;
#[http://www.amazon.com/Intraoperative-Neurophysiological-Monitoring-Aage-Møller/dp/1588297039/tag=clinicalneurophy Intraoperative Neurophysiological Monitoring] by Aage R. Møller&lt;br /&gt;
#[http://www.amazon.com/Intraoperative-Monitoring-Neural-Function-Neurophysiology/dp/044451824X/tag=clinicalneurophy Intraoperative Monitoring of Neural Function: Handbook of Clinical Neurophysiology] by  Marc R. Nuwer&lt;br /&gt;
&lt;br /&gt;
==Journals==&lt;br /&gt;
&lt;br /&gt;
#[http://journals.lww.com/clinicalneurophys/pages/default.aspx  Journal of Clinical Neurophysiology] Official Journal of the American Clinical Neurophysiology Society.&lt;br /&gt;
#[http://www.journals.elsevier.com/clinical-neurophysiology Clinical Neurophysiology] The official journal of the International Federation of Clinical Neurophysiology. It is dedicated to fostering research and disseminating information on all aspects of Clinical Neurophysiology.&lt;br /&gt;
#[http://www.the-aps.org/mm/Publications/Journals/JN Journal of Neurophysiology] publishes original articles on the function of the nervous system, from American Physiological Society.&lt;br /&gt;
#[http://onlinelibrary.wiley.com/journal/10.1002/%28ISSN%291097-4598 Muscle &amp;amp; Nerve] Journal of American Association of Neuromuscular &amp;amp; Electrodiagnostic Medicine.&lt;br /&gt;
#[http://thejns.org/ Journal of Neurosurgery]&lt;br /&gt;
#[http://www.jneurosci.org/  The Journal of Neuroscience] published by Society for Neuroscience.&lt;br /&gt;
&lt;br /&gt;
==Web discussion forums==&lt;br /&gt;
&lt;br /&gt;
==Mailing lists==&lt;br /&gt;
#The Neuromonitoring mailing list - is for anyone with a professional or scientific interest in neuromonitoring. To subscribe, send email to listproc@usc.edu with the following request &amp;quot;subscribe NEUROMON-L Your Name&amp;quot;.&lt;br /&gt;
#[http://home.ease.lsoft.com/scripts/wa-HOME.exe?A0=EPILEPSY-L  EPILEPSY-L: Epilepsy support group] is an email based support group (discussion list) for people with epilepsy and those who care about and for them.&lt;br /&gt;
&lt;br /&gt;
==Study resources==&lt;br /&gt;
&lt;br /&gt;
#[http://www.ptcny.com/clients/ABNM/ABNM.html  Certification Examination in Neurophysiologic Monitoring] ABNM Board exam by American Board of Neurophysiologic Monitoring&lt;br /&gt;
#[http://www.ptcny.com/clients/ABRET/#Certification%20Examination%20in%20Neurophysiologic%20Intraoperative%20Monitoring Certification Examination in Neurophysiologic Intraoperative Monitoring] ABRET-CNIM by American Board of Registration of Electroencephalographic and Evoked Potential Technologists.&lt;br /&gt;
#[http://larryheadinstituteonline.com/lh/courses/ionm-training/ IONM Training] at Larry Head Institute&lt;br /&gt;
&lt;br /&gt;
==Jobs==&lt;br /&gt;
&lt;br /&gt;
#[http://www.asnm.org/?page=Careers Job postings] for ASNM memebers&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=General_Information&amp;diff=196</id>
		<title>General Information</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=General_Information&amp;diff=196"/>
		<updated>2018-04-12T16:44:01Z</updated>

		<summary type="html">&lt;p&gt;Bpw: /* Conferences */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Introduction==&lt;br /&gt;
&lt;br /&gt;
==Organizations==&lt;br /&gt;
&lt;br /&gt;
#[http://www.asnm.org American Society of Neurophysiological Monitoring]&lt;br /&gt;
#[http://www.acns.org American Clinical Neurophysiology Society]&lt;br /&gt;
#[http://www.aset.org The Neurodiagnostic Society (ASET)]&lt;br /&gt;
#[http://abnm.info American Board of Neurophysiologic Monitoring]&lt;br /&gt;
#[http://www.neurophysiology.org International Society of Intraoperative Neurophysiology (ISIN)]&lt;br /&gt;
#[http://www.ifcn.info International Federation of Clinical Neurophysiology]&lt;br /&gt;
#[http://www.aan.com  American Academy of Neurology]&lt;br /&gt;
#[http://www.oegkn.at/translat.htm Austrian Society for Clinical Neurophysiology]&lt;br /&gt;
#[http://www.neurofisiologia.net Italian Neurophysiological Technologists]&lt;br /&gt;
#[http://www.smnfc.com  Mexican Clinical Neurophysiology Society] Represents all certified clinical neurophysiologists in Mexico, with local and global event information in Spanish.&lt;br /&gt;
&lt;br /&gt;
==Conferences==&lt;br /&gt;
&lt;br /&gt;
#[http://www.asnm.org/resource/resmgr/Events/2018/Annual/2018_Annual_Agenda.pdf ASNM Annual Meeting] February 23-25, 2018 - Lake Buena Vista, Florida&lt;br /&gt;
#[http://www.asnm.org/events/EventDetails.aspx?id=1091780 ASNM Fall Symposium] September 15-16, 2017 - Nashville, Tennessee&lt;br /&gt;
#[http://www.acns.org/meetings/annual-meeting-and-courses/2014/program American Clinical Neurophysiology Society Annual Meeting &amp;amp; Courses] February 4-9, 2014, Atlanta, Georgia.&lt;br /&gt;
#[http://www.isincapetown2013.com 4th International Conference on Intraoperative Neurophysiology] November 14-16, 2013, Cape Town, South Africa.&lt;br /&gt;
#[https://asnm.site-ym.com/?page=2013Annual ASNM 2013 Annual Meeting] Procedure Based IONM &amp;amp; State-Of-The-Art Scientific Discussion, May 2-5, 2013, Boston, Massachusetts.&lt;br /&gt;
&lt;br /&gt;
==Books==&lt;br /&gt;
#[http://www.amazon.com/Intraoperative-Neurophysiology-Mirela-Simon-MD-ebook/dp/B004MME2HY/tag=clinicalneurophy Intraoperative Neurophysiology] by Mirela Simon&lt;br /&gt;
#[http://www.amazon.com/Neurophysiology-Neurosurgery-Modern-Intraoperative-Approach/dp/0122090365/tag=clinicalneurophy Neurophysiology in Neurosurgery: A Modern Intraoperative Approach] by  Vedran Deletis and Jay Shils&lt;br /&gt;
#[http://www.amazon.com/Intraoperative-Neurophysiological-Monitoring-Aage-Møller/dp/1588297039/tag=clinicalneurophy Intraoperative Neurophysiological Monitoring] by Aage R. Møller&lt;br /&gt;
#[http://www.amazon.com/Intraoperative-Monitoring-Neural-Function-Neurophysiology/dp/044451824X/tag=clinicalneurophy Intraoperative Monitoring of Neural Function: Handbook of Clinical Neurophysiology] by  Marc R. Nuwer&lt;br /&gt;
&lt;br /&gt;
==Journals==&lt;br /&gt;
&lt;br /&gt;
#[http://journals.lww.com/clinicalneurophys/pages/default.aspx  Journal of Clinical Neurophysiology] Official Journal of the American Clinical Neurophysiology Society.&lt;br /&gt;
#[http://www.journals.elsevier.com/clinical-neurophysiology Clinical Neurophysiology] The official journal of the International Federation of Clinical Neurophysiology. It is dedicated to fostering research and disseminating information on all aspects of Clinical Neurophysiology.&lt;br /&gt;
#[http://www.the-aps.org/mm/Publications/Journals/JN Journal of Neurophysiology] publishes original articles on the function of the nervous system, from American Physiological Society.&lt;br /&gt;
#[http://onlinelibrary.wiley.com/journal/10.1002/%28ISSN%291097-4598 Muscle &amp;amp; Nerve] Journal of American Association of Neuromuscular &amp;amp; Electrodiagnostic Medicine.&lt;br /&gt;
#[http://thejns.org/ Journal of Neurosurgery]&lt;br /&gt;
#[http://www.jneurosci.org/  The Journal of Neuroscience] published by Society for Neuroscience.&lt;br /&gt;
&lt;br /&gt;
==Web discussion forums==&lt;br /&gt;
&lt;br /&gt;
==Mailing lists==&lt;br /&gt;
#The Neuromonitoring mailing list - is for anyone with a professional or scientific interest in neuromonitoring. To subscribe, send email to listproc@usc.edu with the following request &amp;quot;subscribe NEUROMON-L Your Name&amp;quot;.&lt;br /&gt;
#[http://home.ease.lsoft.com/scripts/wa-HOME.exe?A0=EPILEPSY-L  EPILEPSY-L: Epilepsy support group] is an email based support group (discussion list) for people with epilepsy and those who care about and for them.&lt;br /&gt;
&lt;br /&gt;
==Study resources==&lt;br /&gt;
&lt;br /&gt;
#[http://www.ptcny.com/clients/ABNM/ABNM.html  Certification Examination in Neurophysiologic Monitoring] ABNM Board exam by American Board of Neurophysiologic Monitoring&lt;br /&gt;
#[http://www.ptcny.com/clients/ABRET/#Certification%20Examination%20in%20Neurophysiologic%20Intraoperative%20Monitoring Certification Examination in Neurophysiologic Intraoperative Monitoring] ABRET-CNIM by American Board of Registration of Electroencephalographic and Evoked Potential Technologists.&lt;br /&gt;
#[http://larryheadinstituteonline.com/lh/courses/ionm-training/ IONM Training] at Larry Head Institute&lt;br /&gt;
&lt;br /&gt;
==Jobs==&lt;br /&gt;
&lt;br /&gt;
#[http://www.asnm.org/?page=Careers Job postings] for ASNM memebers&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=General_Information&amp;diff=195</id>
		<title>General Information</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=General_Information&amp;diff=195"/>
		<updated>2018-04-12T16:40:33Z</updated>

		<summary type="html">&lt;p&gt;Bpw: /* Conferences */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Introduction==&lt;br /&gt;
&lt;br /&gt;
==Organizations==&lt;br /&gt;
&lt;br /&gt;
#[http://www.asnm.org American Society of Neurophysiological Monitoring]&lt;br /&gt;
#[http://www.acns.org American Clinical Neurophysiology Society]&lt;br /&gt;
#[http://www.aset.org The Neurodiagnostic Society (ASET)]&lt;br /&gt;
#[http://abnm.info American Board of Neurophysiologic Monitoring]&lt;br /&gt;
#[http://www.neurophysiology.org International Society of Intraoperative Neurophysiology (ISIN)]&lt;br /&gt;
#[http://www.ifcn.info International Federation of Clinical Neurophysiology]&lt;br /&gt;
#[http://www.aan.com  American Academy of Neurology]&lt;br /&gt;
#[http://www.oegkn.at/translat.htm Austrian Society for Clinical Neurophysiology]&lt;br /&gt;
#[http://www.neurofisiologia.net Italian Neurophysiological Technologists]&lt;br /&gt;
#[http://www.smnfc.com  Mexican Clinical Neurophysiology Society] Represents all certified clinical neurophysiologists in Mexico, with local and global event information in Spanish.&lt;br /&gt;
&lt;br /&gt;
==Conferences==&lt;br /&gt;
&lt;br /&gt;
#[http://www.asnm.org/resource/resmgr/Events/2018/Annual/2018_Annual_Agenda.pdf ASNM Annual Meeting] February 23-25, 2018 - Lake Buena Vista, Florida&lt;br /&gt;
#[http://www.acns.org/meetings/annual-meeting-and-courses/2014/program American Clinical Neurophysiology Society Annual Meeting &amp;amp; Courses] February 4-9, 2014, Atlanta, Georgia.&lt;br /&gt;
#[http://www.isincapetown2013.com 4th International Conference on Intraoperative Neurophysiology] November 14-16, 2013, Cape Town, South Africa.&lt;br /&gt;
#[https://asnm.site-ym.com/?page=2013Annual ASNM 2013 Annual Meeting] Procedure Based IONM &amp;amp; State-Of-The-Art Scientific Discussion, May 2-5, 2013, Boston, Massachusetts.&lt;br /&gt;
&lt;br /&gt;
==Books==&lt;br /&gt;
#[http://www.amazon.com/Intraoperative-Neurophysiology-Mirela-Simon-MD-ebook/dp/B004MME2HY/tag=clinicalneurophy Intraoperative Neurophysiology] by Mirela Simon&lt;br /&gt;
#[http://www.amazon.com/Neurophysiology-Neurosurgery-Modern-Intraoperative-Approach/dp/0122090365/tag=clinicalneurophy Neurophysiology in Neurosurgery: A Modern Intraoperative Approach] by  Vedran Deletis and Jay Shils&lt;br /&gt;
#[http://www.amazon.com/Intraoperative-Neurophysiological-Monitoring-Aage-Møller/dp/1588297039/tag=clinicalneurophy Intraoperative Neurophysiological Monitoring] by Aage R. Møller&lt;br /&gt;
#[http://www.amazon.com/Intraoperative-Monitoring-Neural-Function-Neurophysiology/dp/044451824X/tag=clinicalneurophy Intraoperative Monitoring of Neural Function: Handbook of Clinical Neurophysiology] by  Marc R. Nuwer&lt;br /&gt;
&lt;br /&gt;
==Journals==&lt;br /&gt;
&lt;br /&gt;
#[http://journals.lww.com/clinicalneurophys/pages/default.aspx  Journal of Clinical Neurophysiology] Official Journal of the American Clinical Neurophysiology Society.&lt;br /&gt;
#[http://www.journals.elsevier.com/clinical-neurophysiology Clinical Neurophysiology] The official journal of the International Federation of Clinical Neurophysiology. It is dedicated to fostering research and disseminating information on all aspects of Clinical Neurophysiology.&lt;br /&gt;
#[http://www.the-aps.org/mm/Publications/Journals/JN Journal of Neurophysiology] publishes original articles on the function of the nervous system, from American Physiological Society.&lt;br /&gt;
#[http://onlinelibrary.wiley.com/journal/10.1002/%28ISSN%291097-4598 Muscle &amp;amp; Nerve] Journal of American Association of Neuromuscular &amp;amp; Electrodiagnostic Medicine.&lt;br /&gt;
#[http://thejns.org/ Journal of Neurosurgery]&lt;br /&gt;
#[http://www.jneurosci.org/  The Journal of Neuroscience] published by Society for Neuroscience.&lt;br /&gt;
&lt;br /&gt;
==Web discussion forums==&lt;br /&gt;
&lt;br /&gt;
==Mailing lists==&lt;br /&gt;
#The Neuromonitoring mailing list - is for anyone with a professional or scientific interest in neuromonitoring. To subscribe, send email to listproc@usc.edu with the following request &amp;quot;subscribe NEUROMON-L Your Name&amp;quot;.&lt;br /&gt;
#[http://home.ease.lsoft.com/scripts/wa-HOME.exe?A0=EPILEPSY-L  EPILEPSY-L: Epilepsy support group] is an email based support group (discussion list) for people with epilepsy and those who care about and for them.&lt;br /&gt;
&lt;br /&gt;
==Study resources==&lt;br /&gt;
&lt;br /&gt;
#[http://www.ptcny.com/clients/ABNM/ABNM.html  Certification Examination in Neurophysiologic Monitoring] ABNM Board exam by American Board of Neurophysiologic Monitoring&lt;br /&gt;
#[http://www.ptcny.com/clients/ABRET/#Certification%20Examination%20in%20Neurophysiologic%20Intraoperative%20Monitoring Certification Examination in Neurophysiologic Intraoperative Monitoring] ABRET-CNIM by American Board of Registration of Electroencephalographic and Evoked Potential Technologists.&lt;br /&gt;
#[http://larryheadinstituteonline.com/lh/courses/ionm-training/ IONM Training] at Larry Head Institute&lt;br /&gt;
&lt;br /&gt;
==Jobs==&lt;br /&gt;
&lt;br /&gt;
#[http://www.asnm.org/?page=Careers Job postings] for ASNM memebers&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=General_Information&amp;diff=194</id>
		<title>General Information</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=General_Information&amp;diff=194"/>
		<updated>2018-04-12T16:39:40Z</updated>

		<summary type="html">&lt;p&gt;Bpw: /* Conferences */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Introduction==&lt;br /&gt;
&lt;br /&gt;
==Organizations==&lt;br /&gt;
&lt;br /&gt;
#[http://www.asnm.org American Society of Neurophysiological Monitoring]&lt;br /&gt;
#[http://www.acns.org American Clinical Neurophysiology Society]&lt;br /&gt;
#[http://www.aset.org The Neurodiagnostic Society (ASET)]&lt;br /&gt;
#[http://abnm.info American Board of Neurophysiologic Monitoring]&lt;br /&gt;
#[http://www.neurophysiology.org International Society of Intraoperative Neurophysiology (ISIN)]&lt;br /&gt;
#[http://www.ifcn.info International Federation of Clinical Neurophysiology]&lt;br /&gt;
#[http://www.aan.com  American Academy of Neurology]&lt;br /&gt;
#[http://www.oegkn.at/translat.htm Austrian Society for Clinical Neurophysiology]&lt;br /&gt;
#[http://www.neurofisiologia.net Italian Neurophysiological Technologists]&lt;br /&gt;
#[http://www.smnfc.com  Mexican Clinical Neurophysiology Society] Represents all certified clinical neurophysiologists in Mexico, with local and global event information in Spanish.&lt;br /&gt;
&lt;br /&gt;
==Conferences==&lt;br /&gt;
&lt;br /&gt;
#[http://www.asnm.org/resource/resmgr/Events/2018/Annual/2018_Annual_Agenda.pdf] February 23-25, 2018 - Lake Buena Vista, Florida&lt;br /&gt;
#[http://www.acns.org/meetings/annual-meeting-and-courses/2014/program American Clinical Neurophysiology Society Annual Meeting &amp;amp; Courses] February 4-9, 2014, Atlanta, Georgia.&lt;br /&gt;
#[http://www.isincapetown2013.com 4th International Conference on Intraoperative Neurophysiology] November 14-16, 2013, Cape Town, South Africa.&lt;br /&gt;
#[https://asnm.site-ym.com/?page=2013Annual ASNM 2013 Annual Meeting] Procedure Based IONM &amp;amp; State-Of-The-Art Scientific Discussion, May 2-5, 2013, Boston, Massachusetts.&lt;br /&gt;
&lt;br /&gt;
==Books==&lt;br /&gt;
#[http://www.amazon.com/Intraoperative-Neurophysiology-Mirela-Simon-MD-ebook/dp/B004MME2HY/tag=clinicalneurophy Intraoperative Neurophysiology] by Mirela Simon&lt;br /&gt;
#[http://www.amazon.com/Neurophysiology-Neurosurgery-Modern-Intraoperative-Approach/dp/0122090365/tag=clinicalneurophy Neurophysiology in Neurosurgery: A Modern Intraoperative Approach] by  Vedran Deletis and Jay Shils&lt;br /&gt;
#[http://www.amazon.com/Intraoperative-Neurophysiological-Monitoring-Aage-Møller/dp/1588297039/tag=clinicalneurophy Intraoperative Neurophysiological Monitoring] by Aage R. Møller&lt;br /&gt;
#[http://www.amazon.com/Intraoperative-Monitoring-Neural-Function-Neurophysiology/dp/044451824X/tag=clinicalneurophy Intraoperative Monitoring of Neural Function: Handbook of Clinical Neurophysiology] by  Marc R. Nuwer&lt;br /&gt;
&lt;br /&gt;
==Journals==&lt;br /&gt;
&lt;br /&gt;
#[http://journals.lww.com/clinicalneurophys/pages/default.aspx  Journal of Clinical Neurophysiology] Official Journal of the American Clinical Neurophysiology Society.&lt;br /&gt;
#[http://www.journals.elsevier.com/clinical-neurophysiology Clinical Neurophysiology] The official journal of the International Federation of Clinical Neurophysiology. It is dedicated to fostering research and disseminating information on all aspects of Clinical Neurophysiology.&lt;br /&gt;
#[http://www.the-aps.org/mm/Publications/Journals/JN Journal of Neurophysiology] publishes original articles on the function of the nervous system, from American Physiological Society.&lt;br /&gt;
#[http://onlinelibrary.wiley.com/journal/10.1002/%28ISSN%291097-4598 Muscle &amp;amp; Nerve] Journal of American Association of Neuromuscular &amp;amp; Electrodiagnostic Medicine.&lt;br /&gt;
#[http://thejns.org/ Journal of Neurosurgery]&lt;br /&gt;
#[http://www.jneurosci.org/  The Journal of Neuroscience] published by Society for Neuroscience.&lt;br /&gt;
&lt;br /&gt;
==Web discussion forums==&lt;br /&gt;
&lt;br /&gt;
==Mailing lists==&lt;br /&gt;
#The Neuromonitoring mailing list - is for anyone with a professional or scientific interest in neuromonitoring. To subscribe, send email to listproc@usc.edu with the following request &amp;quot;subscribe NEUROMON-L Your Name&amp;quot;.&lt;br /&gt;
#[http://home.ease.lsoft.com/scripts/wa-HOME.exe?A0=EPILEPSY-L  EPILEPSY-L: Epilepsy support group] is an email based support group (discussion list) for people with epilepsy and those who care about and for them.&lt;br /&gt;
&lt;br /&gt;
==Study resources==&lt;br /&gt;
&lt;br /&gt;
#[http://www.ptcny.com/clients/ABNM/ABNM.html  Certification Examination in Neurophysiologic Monitoring] ABNM Board exam by American Board of Neurophysiologic Monitoring&lt;br /&gt;
#[http://www.ptcny.com/clients/ABRET/#Certification%20Examination%20in%20Neurophysiologic%20Intraoperative%20Monitoring Certification Examination in Neurophysiologic Intraoperative Monitoring] ABRET-CNIM by American Board of Registration of Electroencephalographic and Evoked Potential Technologists.&lt;br /&gt;
#[http://larryheadinstituteonline.com/lh/courses/ionm-training/ IONM Training] at Larry Head Institute&lt;br /&gt;
&lt;br /&gt;
==Jobs==&lt;br /&gt;
&lt;br /&gt;
#[http://www.asnm.org/?page=Careers Job postings] for ASNM memebers&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=Main_Page&amp;diff=193</id>
		<title>Main Page</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=Main_Page&amp;diff=193"/>
		<updated>2018-04-12T16:34:25Z</updated>

		<summary type="html">&lt;p&gt;Bpw: /* NeurophysPedia : Intraoperative Neurophysiology */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
&lt;br /&gt;
= [[Neurophyspedia : Intraoperative Neurophysiology]] =&lt;br /&gt;
&lt;br /&gt;
Welcome to Neurophyspedia, the Wikipedia for intraoperative neurophysiology.&lt;br /&gt;
&lt;br /&gt;
== [[General Information]]==&lt;br /&gt;
&lt;br /&gt;
== [[Basic Neurophysiology]]  ==&lt;br /&gt;
&lt;br /&gt;
== [[Somatosensory Evoked Potentials (SSEP)]] ==&lt;br /&gt;
&lt;br /&gt;
== [[Motor Evoked Potentials (MEP)]] ==&lt;br /&gt;
&lt;br /&gt;
== [[Brainstem Auditory Evoked Responses (BAER)]] ==&lt;br /&gt;
&lt;br /&gt;
== [[Visual Evoked Potentials (VEP)]] ==&lt;br /&gt;
&lt;br /&gt;
== [[Electroencephalography (EEG)]] ==&lt;br /&gt;
&lt;br /&gt;
== [[Electromyography (EMG)]] ==&lt;br /&gt;
&lt;br /&gt;
== [[Intraoperative Neurophysiological Monitoring (IONM)]] ==&lt;br /&gt;
&lt;br /&gt;
== [[IONM in Cranial Surgery]] ==&lt;br /&gt;
&lt;br /&gt;
== [[IONM in Spinal Surgery]]==&lt;br /&gt;
&lt;br /&gt;
== [[IONM in Peripheral Nerve Surgery]]==&lt;br /&gt;
&lt;br /&gt;
== [[IONM in Vascular Surgery]]==&lt;br /&gt;
&lt;br /&gt;
== [[IONM in Otolaryngological or ENT Surgery]]==&lt;br /&gt;
 &lt;br /&gt;
== [[Neurophysiological Diagnostics]] ==&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=192</id>
		<title>Basic Neurophysiology</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=192"/>
		<updated>2018-04-12T11:57:07Z</updated>

		<summary type="html">&lt;p&gt;Bpw: /* References */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;br /&gt;
&#039;&#039;&#039;Neurophysiology&#039;&#039;&#039; is the study of the function of the nervous system.&lt;br /&gt;
&lt;br /&gt;
== Membrane Ion Channels ==&lt;br /&gt;
&lt;br /&gt;
All animal cells are enclosed in a plasma membrane, which separates its cytoplasm with the extracellular environment. Cell membrane has the structure of a lipid bilayer, with large molecules embedded in it. Concentration of ions are different across the cell membrane, with more sodium ions (Na+) and chloride ions (Cl-) outside the cell, and more potassium ions (K+) and negative charged protein molecules (A-) inside the cell. Selective ion channels at rest allow potassium ions (K+) cross the membrane easily, creating a voltage more negative inside the cell than outside, which is called resting membrane potential. The resting membrane potential of a neuron is about -70 mV.&lt;br /&gt;
&lt;br /&gt;
== Action Potential ==&lt;br /&gt;
&lt;br /&gt;
An action potential is the change in electrical potential associated with the passage of an impulse along the membrane of a muscle cell or nerve cell in response to a stimulus, which occurs as the electrical potential briefly (about 1ms) rises and falls (Hodgkin and Huxley).  Specifically, an action potential occurs when the threshold is reached (-65 mV) which activates the voltage-gated ion channels to open.  When the threshold is reached: Na+ channels open and Na+ rushes into the cell while K+ channels open slowly and K+ leaves the cell, the cell then becomes hyperpolarized (Pinel, 2017).  There are three phases of an action potential: the rising phase (Na+ and K+ channels open), repolarization (Na+ channels close), and hyperpolarization (K+ channels start to close).&lt;br /&gt;
&lt;br /&gt;
== Propagated Neural Activity ==&lt;br /&gt;
&lt;br /&gt;
An action potential is generated near the axon hillock when the threshold is reached (-65 mV), the signal is then propagated down (travels) the axon.  Active axonal conduction is due to the diffusion of Na+ into the cell which creates waves of depolarization whereas passive axonal conduction occurs as the signal travels down a myelinated axon along each segment, an action potential is generated at each node of Ranvier between the segments (Pinel, 2017) propagated from one node to the next (saltatory conduction).&lt;br /&gt;
&lt;br /&gt;
[[File:ion-channels2.png|center|974px|560px]]&lt;br /&gt;
&lt;br /&gt;
(Source: Wikipedia, https://en.wikipedia.org/wiki/Saltatory_conduction)&lt;br /&gt;
&lt;br /&gt;
Axons that are wrapped in myelin (fatty substance), which serves as insulation of the signal, have faster communication than unmyelinated axons.  The nodes of Ranvier are unmyelinated areas on the axon where the ions flow (e.g., Na+, K+).&lt;br /&gt;
&lt;br /&gt;
== Synaptic Transmission ==&lt;br /&gt;
&lt;br /&gt;
The process by which neurons communicate with each other is synaptic transmission which occurs across synapses using either electrical or chemical signals.  Electrical signaling occurs as an action potential travels from the pre- to the postsynaptic neuron via gap junctions.  However, most synaptic transmission involves chemical signals.  These chemicals are neurotransmitters, molecules which can function either directly (ionotropic) or indirectly via second messengers (metabotropic).  The steps in chemical neurotransmission are: synthesis of the neurotransmitter (in the soma), storage of the neurotransmitter in the vesicles, release into the synapse, binding to the receptor on the postsynaptic neuron, and inactivation of the neurotransmitter via reuptake or enzymatic degradation which terminates the action of the neurotransmitter in the synapse.&lt;br /&gt;
&lt;br /&gt;
[[File:synapses.png|center|600px|387px]]&lt;br /&gt;
&lt;br /&gt;
(Source: http://biology4alevel.blogspot.com/2016/06/122-synapses.html)&lt;br /&gt;
&lt;br /&gt;
== Recording Techniques ==&lt;br /&gt;
=== Electrodes  ===&lt;br /&gt;
&lt;br /&gt;
Electrodes are used to deliver and record electrical stimuli.  In Neurophysiology, electrodes deliver auditory, visual, and electrical stimuli, the amplitude, duration, and rate of which can be varied.  Various types of electrodes are used for recording electrophysiological activity from the scalp, nerves, and muscles (Zouridakis and Papanicoloau, 2000).  There are various types of electrodes such as surface electrodes with hydrogel pads, subdermal needle electrodes, and EEG cups.&lt;br /&gt;
&lt;br /&gt;
=== Amplifiers ===&lt;br /&gt;
&lt;br /&gt;
An amplifier multiplies the input voltage to result in a greater output voltage (amplifier is the circuit and the difference between two input voltages).  Specifically, the amplifier functions as the power and converts alternating current to direct current, thereby flowing in only one direction, a resistor then increases the current flow by reducing the resistance.  The signal dictates the amount of the current, such that a greater signal allows for more current and more current results in more amplitude of the signal.&lt;br /&gt;
&lt;br /&gt;
=== Filtering ===&lt;br /&gt;
&lt;br /&gt;
Filters are used to determine the bandwidth while defining the specific content of the frequencies from the recorded signals, thereby attenuating some frequencies in the signal.  Filters can manipulate latency and amplitude.  There are different types of filters including high pass (attenuate high frequencies) and low pass filters (attenuate low frequencies).  High frequency filters will remove all frequencies above a set value (e.g., 5Hz), similarly, low frequency filters will remove frequencies below a set value (e.g., 5Hz).  Another type of filter is the notch filter which will remove one frequency such as the 60Hz, the background or external frequency that can interfere with the recorded neurophysiological signals as it is the frequency of the alternating current used in the power grid.&lt;br /&gt;
&lt;br /&gt;
=== Signal to Noise Ratio ===&lt;br /&gt;
&lt;br /&gt;
Signal to noise ratio refers to the electrical or neuruphysiological signal and the concurrent interference (noise).  Interference occurs both naturally and artificially.  For example, “noise” from the body (extraneous biological activity) or perisurgical such as the use of instrumentation or electrical interference.  The amplitude of the signal and the amplitude of the noise overlap given that the frequency content of noise contains a myriad of all frequencies and the specific frequency content of the signal would be within that range of all frequencies (Zouridakis and Papanicoloau, 2000).  Therefore, to increase specificity and detection of the electrical signal, the signal to noise ratio, the interference must be dampened which can be accomplished using filters as described above and the signal may be increased using averaging.&lt;br /&gt;
&lt;br /&gt;
=== Signal Averaging ===&lt;br /&gt;
&lt;br /&gt;
Evoked potentials elicited by electrical signals are small and a summation and average are thus necessary for detection of the signal (Zouridakis and Papanicoloau, 2000).  Specifically, the process of averaging is used to record evoked potentials, the electrical response in the brain to repeated sensory stimuli.  Given that the individual electrical responses in response to stimuli are small and therefore difficult to distinguish, and that background signals (e.g., ongoing and simultaneous brain activity, other electrical signals) can interfere with this detection, it is assumed that the signal of interest is embedded within all other ongoing electrical activity (noise), therefore summing and averaging improves (increases) the signal to noise ratio by reducing the noise amplitude when the signal to noise ratio (expressed in decibels) is low; the higher the number of trials that are averaged, the lower the noise.  &lt;br /&gt;
&lt;br /&gt;
The time (ms) just before and after the presentation of the stimulus is known as an epoch.  The averaging procedure involves repeated stimulation and signal recording such that each preceding response is added to the most recent (and at each time point), and those values are then divided.  That is, the epoch of each time point is added to all preceding ones and that sum is divided by the total number of epochs (trials).  For multiple channels recording simultaneously, each channel is averaged independently resulting in a separate evoked potential for each channel.   Evoked responses (e.g., sensory or motor) are averaged responses whereas electrically triggered EMG are nonaveraged.&lt;br /&gt;
&lt;br /&gt;
== Electrical Safety ==&lt;br /&gt;
&lt;br /&gt;
There are many sources of electrical activity in the operating theater.  The patient must be protected from the external sources of electrical activity.  One way the patient is protected is by the use of the ground wire (placed subcutaneously) in addition to the needle electrodes that are delivering stimulation.  Also, the neuromonitoring equipment is able to be quickly accessed and detached from the patient, specifically the electrodes can be removed from the cables and/or the cables can be detached from the computer (Moller, 1995).&lt;br /&gt;
&lt;br /&gt;
==References==&lt;br /&gt;
&lt;br /&gt;
# Hodgkin AL and Huxley AF. &amp;quot;A quantitative description of membrane current and its application to conduction and excitation in nerve&amp;quot;. The Journal of Physiology 117.4 (1952): 500–544.&lt;br /&gt;
# Moller, A. (1995).  Intraoperative Neurophysiologic Monitoring.  Informa Healthcare.&lt;br /&gt;
# Pinel, J. P. J. (2014). Biopsychology. Harlow, Essex: Pearson Education Limited.&lt;br /&gt;
# Zouridakis, G. and Papanicoloau, A.C. (2000).  A Concise Guide to Intraoperative Monitoring.  CRC Press: Taylor and Francis Group.&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=191</id>
		<title>Basic Neurophysiology</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=191"/>
		<updated>2018-04-12T11:56:51Z</updated>

		<summary type="html">&lt;p&gt;Bpw: /* References */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;br /&gt;
&#039;&#039;&#039;Neurophysiology&#039;&#039;&#039; is the study of the function of the nervous system.&lt;br /&gt;
&lt;br /&gt;
== Membrane Ion Channels ==&lt;br /&gt;
&lt;br /&gt;
All animal cells are enclosed in a plasma membrane, which separates its cytoplasm with the extracellular environment. Cell membrane has the structure of a lipid bilayer, with large molecules embedded in it. Concentration of ions are different across the cell membrane, with more sodium ions (Na+) and chloride ions (Cl-) outside the cell, and more potassium ions (K+) and negative charged protein molecules (A-) inside the cell. Selective ion channels at rest allow potassium ions (K+) cross the membrane easily, creating a voltage more negative inside the cell than outside, which is called resting membrane potential. The resting membrane potential of a neuron is about -70 mV.&lt;br /&gt;
&lt;br /&gt;
== Action Potential ==&lt;br /&gt;
&lt;br /&gt;
An action potential is the change in electrical potential associated with the passage of an impulse along the membrane of a muscle cell or nerve cell in response to a stimulus, which occurs as the electrical potential briefly (about 1ms) rises and falls (Hodgkin and Huxley).  Specifically, an action potential occurs when the threshold is reached (-65 mV) which activates the voltage-gated ion channels to open.  When the threshold is reached: Na+ channels open and Na+ rushes into the cell while K+ channels open slowly and K+ leaves the cell, the cell then becomes hyperpolarized (Pinel, 2017).  There are three phases of an action potential: the rising phase (Na+ and K+ channels open), repolarization (Na+ channels close), and hyperpolarization (K+ channels start to close).&lt;br /&gt;
&lt;br /&gt;
== Propagated Neural Activity ==&lt;br /&gt;
&lt;br /&gt;
An action potential is generated near the axon hillock when the threshold is reached (-65 mV), the signal is then propagated down (travels) the axon.  Active axonal conduction is due to the diffusion of Na+ into the cell which creates waves of depolarization whereas passive axonal conduction occurs as the signal travels down a myelinated axon along each segment, an action potential is generated at each node of Ranvier between the segments (Pinel, 2017) propagated from one node to the next (saltatory conduction).&lt;br /&gt;
&lt;br /&gt;
[[File:ion-channels2.png|center|974px|560px]]&lt;br /&gt;
&lt;br /&gt;
(Source: Wikipedia, https://en.wikipedia.org/wiki/Saltatory_conduction)&lt;br /&gt;
&lt;br /&gt;
Axons that are wrapped in myelin (fatty substance), which serves as insulation of the signal, have faster communication than unmyelinated axons.  The nodes of Ranvier are unmyelinated areas on the axon where the ions flow (e.g., Na+, K+).&lt;br /&gt;
&lt;br /&gt;
== Synaptic Transmission ==&lt;br /&gt;
&lt;br /&gt;
The process by which neurons communicate with each other is synaptic transmission which occurs across synapses using either electrical or chemical signals.  Electrical signaling occurs as an action potential travels from the pre- to the postsynaptic neuron via gap junctions.  However, most synaptic transmission involves chemical signals.  These chemicals are neurotransmitters, molecules which can function either directly (ionotropic) or indirectly via second messengers (metabotropic).  The steps in chemical neurotransmission are: synthesis of the neurotransmitter (in the soma), storage of the neurotransmitter in the vesicles, release into the synapse, binding to the receptor on the postsynaptic neuron, and inactivation of the neurotransmitter via reuptake or enzymatic degradation which terminates the action of the neurotransmitter in the synapse.&lt;br /&gt;
&lt;br /&gt;
[[File:synapses.png|center|600px|387px]]&lt;br /&gt;
&lt;br /&gt;
(Source: http://biology4alevel.blogspot.com/2016/06/122-synapses.html)&lt;br /&gt;
&lt;br /&gt;
== Recording Techniques ==&lt;br /&gt;
=== Electrodes  ===&lt;br /&gt;
&lt;br /&gt;
Electrodes are used to deliver and record electrical stimuli.  In Neurophysiology, electrodes deliver auditory, visual, and electrical stimuli, the amplitude, duration, and rate of which can be varied.  Various types of electrodes are used for recording electrophysiological activity from the scalp, nerves, and muscles (Zouridakis and Papanicoloau, 2000).  There are various types of electrodes such as surface electrodes with hydrogel pads, subdermal needle electrodes, and EEG cups.&lt;br /&gt;
&lt;br /&gt;
=== Amplifiers ===&lt;br /&gt;
&lt;br /&gt;
An amplifier multiplies the input voltage to result in a greater output voltage (amplifier is the circuit and the difference between two input voltages).  Specifically, the amplifier functions as the power and converts alternating current to direct current, thereby flowing in only one direction, a resistor then increases the current flow by reducing the resistance.  The signal dictates the amount of the current, such that a greater signal allows for more current and more current results in more amplitude of the signal.&lt;br /&gt;
&lt;br /&gt;
=== Filtering ===&lt;br /&gt;
&lt;br /&gt;
Filters are used to determine the bandwidth while defining the specific content of the frequencies from the recorded signals, thereby attenuating some frequencies in the signal.  Filters can manipulate latency and amplitude.  There are different types of filters including high pass (attenuate high frequencies) and low pass filters (attenuate low frequencies).  High frequency filters will remove all frequencies above a set value (e.g., 5Hz), similarly, low frequency filters will remove frequencies below a set value (e.g., 5Hz).  Another type of filter is the notch filter which will remove one frequency such as the 60Hz, the background or external frequency that can interfere with the recorded neurophysiological signals as it is the frequency of the alternating current used in the power grid.&lt;br /&gt;
&lt;br /&gt;
=== Signal to Noise Ratio ===&lt;br /&gt;
&lt;br /&gt;
Signal to noise ratio refers to the electrical or neuruphysiological signal and the concurrent interference (noise).  Interference occurs both naturally and artificially.  For example, “noise” from the body (extraneous biological activity) or perisurgical such as the use of instrumentation or electrical interference.  The amplitude of the signal and the amplitude of the noise overlap given that the frequency content of noise contains a myriad of all frequencies and the specific frequency content of the signal would be within that range of all frequencies (Zouridakis and Papanicoloau, 2000).  Therefore, to increase specificity and detection of the electrical signal, the signal to noise ratio, the interference must be dampened which can be accomplished using filters as described above and the signal may be increased using averaging.&lt;br /&gt;
&lt;br /&gt;
=== Signal Averaging ===&lt;br /&gt;
&lt;br /&gt;
Evoked potentials elicited by electrical signals are small and a summation and average are thus necessary for detection of the signal (Zouridakis and Papanicoloau, 2000).  Specifically, the process of averaging is used to record evoked potentials, the electrical response in the brain to repeated sensory stimuli.  Given that the individual electrical responses in response to stimuli are small and therefore difficult to distinguish, and that background signals (e.g., ongoing and simultaneous brain activity, other electrical signals) can interfere with this detection, it is assumed that the signal of interest is embedded within all other ongoing electrical activity (noise), therefore summing and averaging improves (increases) the signal to noise ratio by reducing the noise amplitude when the signal to noise ratio (expressed in decibels) is low; the higher the number of trials that are averaged, the lower the noise.  &lt;br /&gt;
&lt;br /&gt;
The time (ms) just before and after the presentation of the stimulus is known as an epoch.  The averaging procedure involves repeated stimulation and signal recording such that each preceding response is added to the most recent (and at each time point), and those values are then divided.  That is, the epoch of each time point is added to all preceding ones and that sum is divided by the total number of epochs (trials).  For multiple channels recording simultaneously, each channel is averaged independently resulting in a separate evoked potential for each channel.   Evoked responses (e.g., sensory or motor) are averaged responses whereas electrically triggered EMG are nonaveraged.&lt;br /&gt;
&lt;br /&gt;
== Electrical Safety ==&lt;br /&gt;
&lt;br /&gt;
There are many sources of electrical activity in the operating theater.  The patient must be protected from the external sources of electrical activity.  One way the patient is protected is by the use of the ground wire (placed subcutaneously) in addition to the needle electrodes that are delivering stimulation.  Also, the neuromonitoring equipment is able to be quickly accessed and detached from the patient, specifically the electrodes can be removed from the cables and/or the cables can be detached from the computer (Moller, 1995).&lt;br /&gt;
&lt;br /&gt;
==References==&lt;br /&gt;
&lt;br /&gt;
# Hodgkin AL and Huxley AF. &amp;quot;A quantitative description of membrane current and its application to conduction and excitation in nerve&amp;quot;. The Journal of Physiology 117.4 (1952): 500–544.&lt;br /&gt;
&lt;br /&gt;
# Moller, A. (1995).  Intraoperative Neurophysiologic Monitoring.  Informa Healthcare.&lt;br /&gt;
&lt;br /&gt;
# Pinel, J. P. J. (2014). Biopsychology. Harlow, Essex: Pearson Education Limited.&lt;br /&gt;
&lt;br /&gt;
# Zouridakis, G. and Papanicoloau, A.C. (2000).  A Concise Guide to Intraoperative Monitoring.  CRC Press: Taylor and Francis Group.&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=190</id>
		<title>Basic Neurophysiology</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=190"/>
		<updated>2018-04-11T23:35:10Z</updated>

		<summary type="html">&lt;p&gt;Bpw: /* Propagated Neural Activity */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;br /&gt;
&#039;&#039;&#039;Neurophysiology&#039;&#039;&#039; is the study of the function of the nervous system.&lt;br /&gt;
&lt;br /&gt;
== Membrane Ion Channels ==&lt;br /&gt;
&lt;br /&gt;
All animal cells are enclosed in a plasma membrane, which separates its cytoplasm with the extracellular environment. Cell membrane has the structure of a lipid bilayer, with large molecules embedded in it. Concentration of ions are different across the cell membrane, with more sodium ions (Na+) and chloride ions (Cl-) outside the cell, and more potassium ions (K+) and negative charged protein molecules (A-) inside the cell. Selective ion channels at rest allow potassium ions (K+) cross the membrane easily, creating a voltage more negative inside the cell than outside, which is called resting membrane potential. The resting membrane potential of a neuron is about -70 mV.&lt;br /&gt;
&lt;br /&gt;
== Action Potential ==&lt;br /&gt;
&lt;br /&gt;
An action potential is the change in electrical potential associated with the passage of an impulse along the membrane of a muscle cell or nerve cell in response to a stimulus, which occurs as the electrical potential briefly (about 1ms) rises and falls (Hodgkin and Huxley).  Specifically, an action potential occurs when the threshold is reached (-65 mV) which activates the voltage-gated ion channels to open.  When the threshold is reached: Na+ channels open and Na+ rushes into the cell while K+ channels open slowly and K+ leaves the cell, the cell then becomes hyperpolarized (Pinel, 2017).  There are three phases of an action potential: the rising phase (Na+ and K+ channels open), repolarization (Na+ channels close), and hyperpolarization (K+ channels start to close).&lt;br /&gt;
&lt;br /&gt;
== Propagated Neural Activity ==&lt;br /&gt;
&lt;br /&gt;
An action potential is generated near the axon hillock when the threshold is reached (-65 mV), the signal is then propagated down (travels) the axon.  Active axonal conduction is due to the diffusion of Na+ into the cell which creates waves of depolarization whereas passive axonal conduction occurs as the signal travels down a myelinated axon along each segment, an action potential is generated at each node of Ranvier between the segments (Pinel, 2017) propagated from one node to the next (saltatory conduction).&lt;br /&gt;
&lt;br /&gt;
[[File:ion-channels2.png|center|974px|560px]]&lt;br /&gt;
&lt;br /&gt;
(Source: Wikipedia, https://en.wikipedia.org/wiki/Saltatory_conduction)&lt;br /&gt;
&lt;br /&gt;
Axons that are wrapped in myelin (fatty substance), which serves as insulation of the signal, have faster communication than unmyelinated axons.  The nodes of Ranvier are unmyelinated areas on the axon where the ions flow (e.g., Na+, K+).&lt;br /&gt;
&lt;br /&gt;
== Synaptic Transmission ==&lt;br /&gt;
&lt;br /&gt;
The process by which neurons communicate with each other is synaptic transmission which occurs across synapses using either electrical or chemical signals.  Electrical signaling occurs as an action potential travels from the pre- to the postsynaptic neuron via gap junctions.  However, most synaptic transmission involves chemical signals.  These chemicals are neurotransmitters, molecules which can function either directly (ionotropic) or indirectly via second messengers (metabotropic).  The steps in chemical neurotransmission are: synthesis of the neurotransmitter (in the soma), storage of the neurotransmitter in the vesicles, release into the synapse, binding to the receptor on the postsynaptic neuron, and inactivation of the neurotransmitter via reuptake or enzymatic degradation which terminates the action of the neurotransmitter in the synapse.&lt;br /&gt;
&lt;br /&gt;
[[File:synapses.png|center|600px|387px]]&lt;br /&gt;
&lt;br /&gt;
(Source: http://biology4alevel.blogspot.com/2016/06/122-synapses.html)&lt;br /&gt;
&lt;br /&gt;
== Recording Techniques ==&lt;br /&gt;
=== Electrodes  ===&lt;br /&gt;
&lt;br /&gt;
Electrodes are used to deliver and record electrical stimuli.  In Neurophysiology, electrodes deliver auditory, visual, and electrical stimuli, the amplitude, duration, and rate of which can be varied.  Various types of electrodes are used for recording electrophysiological activity from the scalp, nerves, and muscles (Zouridakis and Papanicoloau, 2000).  There are various types of electrodes such as surface electrodes with hydrogel pads, subdermal needle electrodes, and EEG cups.&lt;br /&gt;
&lt;br /&gt;
=== Amplifiers ===&lt;br /&gt;
&lt;br /&gt;
An amplifier multiplies the input voltage to result in a greater output voltage (amplifier is the circuit and the difference between two input voltages).  Specifically, the amplifier functions as the power and converts alternating current to direct current, thereby flowing in only one direction, a resistor then increases the current flow by reducing the resistance.  The signal dictates the amount of the current, such that a greater signal allows for more current and more current results in more amplitude of the signal.&lt;br /&gt;
&lt;br /&gt;
=== Filtering ===&lt;br /&gt;
&lt;br /&gt;
Filters are used to determine the bandwidth while defining the specific content of the frequencies from the recorded signals, thereby attenuating some frequencies in the signal.  Filters can manipulate latency and amplitude.  There are different types of filters including high pass (attenuate high frequencies) and low pass filters (attenuate low frequencies).  High frequency filters will remove all frequencies above a set value (e.g., 5Hz), similarly, low frequency filters will remove frequencies below a set value (e.g., 5Hz).  Another type of filter is the notch filter which will remove one frequency such as the 60Hz, the background or external frequency that can interfere with the recorded neurophysiological signals as it is the frequency of the alternating current used in the power grid.&lt;br /&gt;
&lt;br /&gt;
=== Signal to Noise Ratio ===&lt;br /&gt;
&lt;br /&gt;
Signal to noise ratio refers to the electrical or neuruphysiological signal and the concurrent interference (noise).  Interference occurs both naturally and artificially.  For example, “noise” from the body (extraneous biological activity) or perisurgical such as the use of instrumentation or electrical interference.  The amplitude of the signal and the amplitude of the noise overlap given that the frequency content of noise contains a myriad of all frequencies and the specific frequency content of the signal would be within that range of all frequencies (Zouridakis and Papanicoloau, 2000).  Therefore, to increase specificity and detection of the electrical signal, the signal to noise ratio, the interference must be dampened which can be accomplished using filters as described above and the signal may be increased using averaging.&lt;br /&gt;
&lt;br /&gt;
=== Signal Averaging ===&lt;br /&gt;
&lt;br /&gt;
Evoked potentials elicited by electrical signals are small and a summation and average are thus necessary for detection of the signal (Zouridakis and Papanicoloau, 2000).  Specifically, the process of averaging is used to record evoked potentials, the electrical response in the brain to repeated sensory stimuli.  Given that the individual electrical responses in response to stimuli are small and therefore difficult to distinguish, and that background signals (e.g., ongoing and simultaneous brain activity, other electrical signals) can interfere with this detection, it is assumed that the signal of interest is embedded within all other ongoing electrical activity (noise), therefore summing and averaging improves (increases) the signal to noise ratio by reducing the noise amplitude when the signal to noise ratio (expressed in decibels) is low; the higher the number of trials that are averaged, the lower the noise.  &lt;br /&gt;
&lt;br /&gt;
The time (ms) just before and after the presentation of the stimulus is known as an epoch.  The averaging procedure involves repeated stimulation and signal recording such that each preceding response is added to the most recent (and at each time point), and those values are then divided.  That is, the epoch of each time point is added to all preceding ones and that sum is divided by the total number of epochs (trials).  For multiple channels recording simultaneously, each channel is averaged independently resulting in a separate evoked potential for each channel.   Evoked responses (e.g., sensory or motor) are averaged responses whereas electrically triggered EMG are nonaveraged.&lt;br /&gt;
&lt;br /&gt;
== Electrical Safety ==&lt;br /&gt;
&lt;br /&gt;
There are many sources of electrical activity in the operating theater.  The patient must be protected from the external sources of electrical activity.  One way the patient is protected is by the use of the ground wire (placed subcutaneously) in addition to the needle electrodes that are delivering stimulation.  Also, the neuromonitoring equipment is able to be quickly accessed and detached from the patient, specifically the electrodes can be removed from the cables and/or the cables can be detached from the computer (Moller, 1995).&lt;br /&gt;
&lt;br /&gt;
==References==&lt;br /&gt;
&lt;br /&gt;
Hodgkin AL and Huxley AF. &amp;quot;A quantitative description of membrane current and its application to conduction and excitation in nerve&amp;quot;. The Journal of Physiology 117.4 (1952): 500–544.&lt;br /&gt;
&lt;br /&gt;
Moller, A. (1995).  Intraoperative Neurophysiologic Monitoring.  Informa Healthcare.&lt;br /&gt;
&lt;br /&gt;
Pinel, J. P. J. (2014). Biopsychology. Harlow, Essex: Pearson Education Limited.&lt;br /&gt;
&lt;br /&gt;
Zouridakis, G. and Papanicoloau, A.C. (2000).  A Concise Guide to Intraoperative Monitoring.  CRC Press: Taylor and Francis Group.&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=File:Ion-channels2.png&amp;diff=189</id>
		<title>File:Ion-channels2.png</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=File:Ion-channels2.png&amp;diff=189"/>
		<updated>2018-04-11T23:34:52Z</updated>

		<summary type="html">&lt;p&gt;Bpw: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=File:Synapses.png&amp;diff=188</id>
		<title>File:Synapses.png</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=File:Synapses.png&amp;diff=188"/>
		<updated>2018-04-11T23:28:56Z</updated>

		<summary type="html">&lt;p&gt;Bpw: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=187</id>
		<title>Basic Neurophysiology</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=187"/>
		<updated>2018-04-11T23:28:28Z</updated>

		<summary type="html">&lt;p&gt;Bpw: /* Synaptic Transmission */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;br /&gt;
&#039;&#039;&#039;Neurophysiology&#039;&#039;&#039; is the study of the function of the nervous system.&lt;br /&gt;
&lt;br /&gt;
== Membrane Ion Channels ==&lt;br /&gt;
&lt;br /&gt;
All animal cells are enclosed in a plasma membrane, which separates its cytoplasm with the extracellular environment. Cell membrane has the structure of a lipid bilayer, with large molecules embedded in it. Concentration of ions are different across the cell membrane, with more sodium ions (Na+) and chloride ions (Cl-) outside the cell, and more potassium ions (K+) and negative charged protein molecules (A-) inside the cell. Selective ion channels at rest allow potassium ions (K+) cross the membrane easily, creating a voltage more negative inside the cell than outside, which is called resting membrane potential. The resting membrane potential of a neuron is about -70 mV.&lt;br /&gt;
&lt;br /&gt;
== Action Potential ==&lt;br /&gt;
&lt;br /&gt;
An action potential is the change in electrical potential associated with the passage of an impulse along the membrane of a muscle cell or nerve cell in response to a stimulus, which occurs as the electrical potential briefly (about 1ms) rises and falls (Hodgkin and Huxley).  Specifically, an action potential occurs when the threshold is reached (-65 mV) which activates the voltage-gated ion channels to open.  When the threshold is reached: Na+ channels open and Na+ rushes into the cell while K+ channels open slowly and K+ leaves the cell, the cell then becomes hyperpolarized (Pinel, 2017).  There are three phases of an action potential: the rising phase (Na+ and K+ channels open), repolarization (Na+ channels close), and hyperpolarization (K+ channels start to close).&lt;br /&gt;
&lt;br /&gt;
== Propagated Neural Activity ==&lt;br /&gt;
&lt;br /&gt;
An action potential is generated near the axon hillock when the threshold is reached (-65 mV), the signal is then propagated down (travels) the axon.  Active axonal conduction is due to the diffusion of Na+ into the cell which creates waves of depolarization whereas passive axonal conduction occurs as the signal travels down a myelinated axon along each segment, an action potential is generated at each node of Ranvier between the segments (Pinel, 2017) propagated from one node to the next (saltatory conduction).&lt;br /&gt;
&lt;br /&gt;
[[File:ion-channels.png|center|974px|560px]]&lt;br /&gt;
&lt;br /&gt;
(Source: Wikipedia, https://en.wikipedia.org/wiki/Saltatory_conduction)&lt;br /&gt;
&lt;br /&gt;
Axons that are wrapped in myelin (fatty substance), which serves as insulation of the signal, have faster communication than unmyelinated axons.  The nodes of Ranvier are unmyelinated areas on the axon where the ions flow (e.g., Na+, K+).&lt;br /&gt;
&lt;br /&gt;
== Synaptic Transmission ==&lt;br /&gt;
&lt;br /&gt;
The process by which neurons communicate with each other is synaptic transmission which occurs across synapses using either electrical or chemical signals.  Electrical signaling occurs as an action potential travels from the pre- to the postsynaptic neuron via gap junctions.  However, most synaptic transmission involves chemical signals.  These chemicals are neurotransmitters, molecules which can function either directly (ionotropic) or indirectly via second messengers (metabotropic).  The steps in chemical neurotransmission are: synthesis of the neurotransmitter (in the soma), storage of the neurotransmitter in the vesicles, release into the synapse, binding to the receptor on the postsynaptic neuron, and inactivation of the neurotransmitter via reuptake or enzymatic degradation which terminates the action of the neurotransmitter in the synapse.&lt;br /&gt;
&lt;br /&gt;
[[File:synapses.png|center|600px|387px]]&lt;br /&gt;
&lt;br /&gt;
(Source: http://biology4alevel.blogspot.com/2016/06/122-synapses.html)&lt;br /&gt;
&lt;br /&gt;
== Recording Techniques ==&lt;br /&gt;
=== Electrodes  ===&lt;br /&gt;
&lt;br /&gt;
Electrodes are used to deliver and record electrical stimuli.  In Neurophysiology, electrodes deliver auditory, visual, and electrical stimuli, the amplitude, duration, and rate of which can be varied.  Various types of electrodes are used for recording electrophysiological activity from the scalp, nerves, and muscles (Zouridakis and Papanicoloau, 2000).  There are various types of electrodes such as surface electrodes with hydrogel pads, subdermal needle electrodes, and EEG cups.&lt;br /&gt;
&lt;br /&gt;
=== Amplifiers ===&lt;br /&gt;
&lt;br /&gt;
An amplifier multiplies the input voltage to result in a greater output voltage (amplifier is the circuit and the difference between two input voltages).  Specifically, the amplifier functions as the power and converts alternating current to direct current, thereby flowing in only one direction, a resistor then increases the current flow by reducing the resistance.  The signal dictates the amount of the current, such that a greater signal allows for more current and more current results in more amplitude of the signal.&lt;br /&gt;
&lt;br /&gt;
=== Filtering ===&lt;br /&gt;
&lt;br /&gt;
Filters are used to determine the bandwidth while defining the specific content of the frequencies from the recorded signals, thereby attenuating some frequencies in the signal.  Filters can manipulate latency and amplitude.  There are different types of filters including high pass (attenuate high frequencies) and low pass filters (attenuate low frequencies).  High frequency filters will remove all frequencies above a set value (e.g., 5Hz), similarly, low frequency filters will remove frequencies below a set value (e.g., 5Hz).  Another type of filter is the notch filter which will remove one frequency such as the 60Hz, the background or external frequency that can interfere with the recorded neurophysiological signals as it is the frequency of the alternating current used in the power grid.&lt;br /&gt;
&lt;br /&gt;
=== Signal to Noise Ratio ===&lt;br /&gt;
&lt;br /&gt;
Signal to noise ratio refers to the electrical or neuruphysiological signal and the concurrent interference (noise).  Interference occurs both naturally and artificially.  For example, “noise” from the body (extraneous biological activity) or perisurgical such as the use of instrumentation or electrical interference.  The amplitude of the signal and the amplitude of the noise overlap given that the frequency content of noise contains a myriad of all frequencies and the specific frequency content of the signal would be within that range of all frequencies (Zouridakis and Papanicoloau, 2000).  Therefore, to increase specificity and detection of the electrical signal, the signal to noise ratio, the interference must be dampened which can be accomplished using filters as described above and the signal may be increased using averaging.&lt;br /&gt;
&lt;br /&gt;
=== Signal Averaging ===&lt;br /&gt;
&lt;br /&gt;
Evoked potentials elicited by electrical signals are small and a summation and average are thus necessary for detection of the signal (Zouridakis and Papanicoloau, 2000).  Specifically, the process of averaging is used to record evoked potentials, the electrical response in the brain to repeated sensory stimuli.  Given that the individual electrical responses in response to stimuli are small and therefore difficult to distinguish, and that background signals (e.g., ongoing and simultaneous brain activity, other electrical signals) can interfere with this detection, it is assumed that the signal of interest is embedded within all other ongoing electrical activity (noise), therefore summing and averaging improves (increases) the signal to noise ratio by reducing the noise amplitude when the signal to noise ratio (expressed in decibels) is low; the higher the number of trials that are averaged, the lower the noise.  &lt;br /&gt;
&lt;br /&gt;
The time (ms) just before and after the presentation of the stimulus is known as an epoch.  The averaging procedure involves repeated stimulation and signal recording such that each preceding response is added to the most recent (and at each time point), and those values are then divided.  That is, the epoch of each time point is added to all preceding ones and that sum is divided by the total number of epochs (trials).  For multiple channels recording simultaneously, each channel is averaged independently resulting in a separate evoked potential for each channel.   Evoked responses (e.g., sensory or motor) are averaged responses whereas electrically triggered EMG are nonaveraged.&lt;br /&gt;
&lt;br /&gt;
== Electrical Safety ==&lt;br /&gt;
&lt;br /&gt;
There are many sources of electrical activity in the operating theater.  The patient must be protected from the external sources of electrical activity.  One way the patient is protected is by the use of the ground wire (placed subcutaneously) in addition to the needle electrodes that are delivering stimulation.  Also, the neuromonitoring equipment is able to be quickly accessed and detached from the patient, specifically the electrodes can be removed from the cables and/or the cables can be detached from the computer (Moller, 1995).&lt;br /&gt;
&lt;br /&gt;
==References==&lt;br /&gt;
&lt;br /&gt;
Hodgkin AL and Huxley AF. &amp;quot;A quantitative description of membrane current and its application to conduction and excitation in nerve&amp;quot;. The Journal of Physiology 117.4 (1952): 500–544.&lt;br /&gt;
&lt;br /&gt;
Moller, A. (1995).  Intraoperative Neurophysiologic Monitoring.  Informa Healthcare.&lt;br /&gt;
&lt;br /&gt;
Pinel, J. P. J. (2014). Biopsychology. Harlow, Essex: Pearson Education Limited.&lt;br /&gt;
&lt;br /&gt;
Zouridakis, G. and Papanicoloau, A.C. (2000).  A Concise Guide to Intraoperative Monitoring.  CRC Press: Taylor and Francis Group.&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=186</id>
		<title>Basic Neurophysiology</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=186"/>
		<updated>2018-04-11T23:25:26Z</updated>

		<summary type="html">&lt;p&gt;Bpw: /* Synaptic Transmission */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;br /&gt;
&#039;&#039;&#039;Neurophysiology&#039;&#039;&#039; is the study of the function of the nervous system.&lt;br /&gt;
&lt;br /&gt;
== Membrane Ion Channels ==&lt;br /&gt;
&lt;br /&gt;
All animal cells are enclosed in a plasma membrane, which separates its cytoplasm with the extracellular environment. Cell membrane has the structure of a lipid bilayer, with large molecules embedded in it. Concentration of ions are different across the cell membrane, with more sodium ions (Na+) and chloride ions (Cl-) outside the cell, and more potassium ions (K+) and negative charged protein molecules (A-) inside the cell. Selective ion channels at rest allow potassium ions (K+) cross the membrane easily, creating a voltage more negative inside the cell than outside, which is called resting membrane potential. The resting membrane potential of a neuron is about -70 mV.&lt;br /&gt;
&lt;br /&gt;
== Action Potential ==&lt;br /&gt;
&lt;br /&gt;
An action potential is the change in electrical potential associated with the passage of an impulse along the membrane of a muscle cell or nerve cell in response to a stimulus, which occurs as the electrical potential briefly (about 1ms) rises and falls (Hodgkin and Huxley).  Specifically, an action potential occurs when the threshold is reached (-65 mV) which activates the voltage-gated ion channels to open.  When the threshold is reached: Na+ channels open and Na+ rushes into the cell while K+ channels open slowly and K+ leaves the cell, the cell then becomes hyperpolarized (Pinel, 2017).  There are three phases of an action potential: the rising phase (Na+ and K+ channels open), repolarization (Na+ channels close), and hyperpolarization (K+ channels start to close).&lt;br /&gt;
&lt;br /&gt;
== Propagated Neural Activity ==&lt;br /&gt;
&lt;br /&gt;
An action potential is generated near the axon hillock when the threshold is reached (-65 mV), the signal is then propagated down (travels) the axon.  Active axonal conduction is due to the diffusion of Na+ into the cell which creates waves of depolarization whereas passive axonal conduction occurs as the signal travels down a myelinated axon along each segment, an action potential is generated at each node of Ranvier between the segments (Pinel, 2017) propagated from one node to the next (saltatory conduction).&lt;br /&gt;
&lt;br /&gt;
[[File:ion-channels.png|center|974px|560px]]&lt;br /&gt;
&lt;br /&gt;
(Source: Wikipedia, https://en.wikipedia.org/wiki/Saltatory_conduction)&lt;br /&gt;
&lt;br /&gt;
Axons that are wrapped in myelin (fatty substance), which serves as insulation of the signal, have faster communication than unmyelinated axons.  The nodes of Ranvier are unmyelinated areas on the axon where the ions flow (e.g., Na+, K+).&lt;br /&gt;
&lt;br /&gt;
== Synaptic Transmission ==&lt;br /&gt;
&lt;br /&gt;
The process by which neurons communicate with each other is synaptic transmission which occurs across synapses using either electrical or chemical signals.  Electrical signaling occurs as an action potential travels from the pre- to the postsynaptic neuron via gap junctions.  However, most synaptic transmission involves chemical signals.  These chemicals are neurotransmitters, molecules which can function either directly (ionotropic) or indirectly via second messengers (metabotropic).  The steps in chemical neurotransmission are: synthesis of the neurotransmitter (in the soma), storage of the neurotransmitter in the vesicles, release into the synapse, binding to the receptor on the postsynaptic neuron, and inactivation of the neurotransmitter via reuptake or enzymatic degradation which terminates the action of the neurotransmitter in the synapse.&lt;br /&gt;
&lt;br /&gt;
synapses.png&lt;br /&gt;
&lt;br /&gt;
== Recording Techniques ==&lt;br /&gt;
=== Electrodes  ===&lt;br /&gt;
&lt;br /&gt;
Electrodes are used to deliver and record electrical stimuli.  In Neurophysiology, electrodes deliver auditory, visual, and electrical stimuli, the amplitude, duration, and rate of which can be varied.  Various types of electrodes are used for recording electrophysiological activity from the scalp, nerves, and muscles (Zouridakis and Papanicoloau, 2000).  There are various types of electrodes such as surface electrodes with hydrogel pads, subdermal needle electrodes, and EEG cups.&lt;br /&gt;
&lt;br /&gt;
=== Amplifiers ===&lt;br /&gt;
&lt;br /&gt;
An amplifier multiplies the input voltage to result in a greater output voltage (amplifier is the circuit and the difference between two input voltages).  Specifically, the amplifier functions as the power and converts alternating current to direct current, thereby flowing in only one direction, a resistor then increases the current flow by reducing the resistance.  The signal dictates the amount of the current, such that a greater signal allows for more current and more current results in more amplitude of the signal.&lt;br /&gt;
&lt;br /&gt;
=== Filtering ===&lt;br /&gt;
&lt;br /&gt;
Filters are used to determine the bandwidth while defining the specific content of the frequencies from the recorded signals, thereby attenuating some frequencies in the signal.  Filters can manipulate latency and amplitude.  There are different types of filters including high pass (attenuate high frequencies) and low pass filters (attenuate low frequencies).  High frequency filters will remove all frequencies above a set value (e.g., 5Hz), similarly, low frequency filters will remove frequencies below a set value (e.g., 5Hz).  Another type of filter is the notch filter which will remove one frequency such as the 60Hz, the background or external frequency that can interfere with the recorded neurophysiological signals as it is the frequency of the alternating current used in the power grid.&lt;br /&gt;
&lt;br /&gt;
=== Signal to Noise Ratio ===&lt;br /&gt;
&lt;br /&gt;
Signal to noise ratio refers to the electrical or neuruphysiological signal and the concurrent interference (noise).  Interference occurs both naturally and artificially.  For example, “noise” from the body (extraneous biological activity) or perisurgical such as the use of instrumentation or electrical interference.  The amplitude of the signal and the amplitude of the noise overlap given that the frequency content of noise contains a myriad of all frequencies and the specific frequency content of the signal would be within that range of all frequencies (Zouridakis and Papanicoloau, 2000).  Therefore, to increase specificity and detection of the electrical signal, the signal to noise ratio, the interference must be dampened which can be accomplished using filters as described above and the signal may be increased using averaging.&lt;br /&gt;
&lt;br /&gt;
=== Signal Averaging ===&lt;br /&gt;
&lt;br /&gt;
Evoked potentials elicited by electrical signals are small and a summation and average are thus necessary for detection of the signal (Zouridakis and Papanicoloau, 2000).  Specifically, the process of averaging is used to record evoked potentials, the electrical response in the brain to repeated sensory stimuli.  Given that the individual electrical responses in response to stimuli are small and therefore difficult to distinguish, and that background signals (e.g., ongoing and simultaneous brain activity, other electrical signals) can interfere with this detection, it is assumed that the signal of interest is embedded within all other ongoing electrical activity (noise), therefore summing and averaging improves (increases) the signal to noise ratio by reducing the noise amplitude when the signal to noise ratio (expressed in decibels) is low; the higher the number of trials that are averaged, the lower the noise.  &lt;br /&gt;
&lt;br /&gt;
The time (ms) just before and after the presentation of the stimulus is known as an epoch.  The averaging procedure involves repeated stimulation and signal recording such that each preceding response is added to the most recent (and at each time point), and those values are then divided.  That is, the epoch of each time point is added to all preceding ones and that sum is divided by the total number of epochs (trials).  For multiple channels recording simultaneously, each channel is averaged independently resulting in a separate evoked potential for each channel.   Evoked responses (e.g., sensory or motor) are averaged responses whereas electrically triggered EMG are nonaveraged.&lt;br /&gt;
&lt;br /&gt;
== Electrical Safety ==&lt;br /&gt;
&lt;br /&gt;
There are many sources of electrical activity in the operating theater.  The patient must be protected from the external sources of electrical activity.  One way the patient is protected is by the use of the ground wire (placed subcutaneously) in addition to the needle electrodes that are delivering stimulation.  Also, the neuromonitoring equipment is able to be quickly accessed and detached from the patient, specifically the electrodes can be removed from the cables and/or the cables can be detached from the computer (Moller, 1995).&lt;br /&gt;
&lt;br /&gt;
==References==&lt;br /&gt;
&lt;br /&gt;
Hodgkin AL and Huxley AF. &amp;quot;A quantitative description of membrane current and its application to conduction and excitation in nerve&amp;quot;. The Journal of Physiology 117.4 (1952): 500–544.&lt;br /&gt;
&lt;br /&gt;
Moller, A. (1995).  Intraoperative Neurophysiologic Monitoring.  Informa Healthcare.&lt;br /&gt;
&lt;br /&gt;
Pinel, J. P. J. (2014). Biopsychology. Harlow, Essex: Pearson Education Limited.&lt;br /&gt;
&lt;br /&gt;
Zouridakis, G. and Papanicoloau, A.C. (2000).  A Concise Guide to Intraoperative Monitoring.  CRC Press: Taylor and Francis Group.&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=185</id>
		<title>Basic Neurophysiology</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=185"/>
		<updated>2018-04-11T23:24:14Z</updated>

		<summary type="html">&lt;p&gt;Bpw: /* Propagated Neural Activity */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;br /&gt;
&#039;&#039;&#039;Neurophysiology&#039;&#039;&#039; is the study of the function of the nervous system.&lt;br /&gt;
&lt;br /&gt;
== Membrane Ion Channels ==&lt;br /&gt;
&lt;br /&gt;
All animal cells are enclosed in a plasma membrane, which separates its cytoplasm with the extracellular environment. Cell membrane has the structure of a lipid bilayer, with large molecules embedded in it. Concentration of ions are different across the cell membrane, with more sodium ions (Na+) and chloride ions (Cl-) outside the cell, and more potassium ions (K+) and negative charged protein molecules (A-) inside the cell. Selective ion channels at rest allow potassium ions (K+) cross the membrane easily, creating a voltage more negative inside the cell than outside, which is called resting membrane potential. The resting membrane potential of a neuron is about -70 mV.&lt;br /&gt;
&lt;br /&gt;
== Action Potential ==&lt;br /&gt;
&lt;br /&gt;
An action potential is the change in electrical potential associated with the passage of an impulse along the membrane of a muscle cell or nerve cell in response to a stimulus, which occurs as the electrical potential briefly (about 1ms) rises and falls (Hodgkin and Huxley).  Specifically, an action potential occurs when the threshold is reached (-65 mV) which activates the voltage-gated ion channels to open.  When the threshold is reached: Na+ channels open and Na+ rushes into the cell while K+ channels open slowly and K+ leaves the cell, the cell then becomes hyperpolarized (Pinel, 2017).  There are three phases of an action potential: the rising phase (Na+ and K+ channels open), repolarization (Na+ channels close), and hyperpolarization (K+ channels start to close).&lt;br /&gt;
&lt;br /&gt;
== Propagated Neural Activity ==&lt;br /&gt;
&lt;br /&gt;
An action potential is generated near the axon hillock when the threshold is reached (-65 mV), the signal is then propagated down (travels) the axon.  Active axonal conduction is due to the diffusion of Na+ into the cell which creates waves of depolarization whereas passive axonal conduction occurs as the signal travels down a myelinated axon along each segment, an action potential is generated at each node of Ranvier between the segments (Pinel, 2017) propagated from one node to the next (saltatory conduction).&lt;br /&gt;
&lt;br /&gt;
[[File:ion-channels.png|center|974px|560px]]&lt;br /&gt;
&lt;br /&gt;
(Source: Wikipedia, https://en.wikipedia.org/wiki/Saltatory_conduction)&lt;br /&gt;
&lt;br /&gt;
Axons that are wrapped in myelin (fatty substance), which serves as insulation of the signal, have faster communication than unmyelinated axons.  The nodes of Ranvier are unmyelinated areas on the axon where the ions flow (e.g., Na+, K+).&lt;br /&gt;
&lt;br /&gt;
== Synaptic Transmission ==&lt;br /&gt;
&lt;br /&gt;
The process by which neurons communicate with each other is synaptic transmission which occurs across synapses using either electrical or chemical signals.  Electrical signaling occurs as an action potential travels from the pre- to the postsynaptic neuron via gap junctions.  However, most synaptic transmission involves chemical signals.  These chemicals are neurotransmitters, molecules which can function either directly (ionotropic) or indirectly via second messengers (metabotropic).  The steps in chemical neurotransmission are: synthesis of the neurotransmitter (in the soma), storage of the neurotransmitter in the vesicles, release into the synapse, binding to the receptor on the postsynaptic neuron, and inactivation of the neurotransmitter via reuptake or enzymatic degradation which terminates the action of the neurotransmitter in the synapse.&lt;br /&gt;
&lt;br /&gt;
== Recording Techniques ==&lt;br /&gt;
=== Electrodes  ===&lt;br /&gt;
&lt;br /&gt;
Electrodes are used to deliver and record electrical stimuli.  In Neurophysiology, electrodes deliver auditory, visual, and electrical stimuli, the amplitude, duration, and rate of which can be varied.  Various types of electrodes are used for recording electrophysiological activity from the scalp, nerves, and muscles (Zouridakis and Papanicoloau, 2000).  There are various types of electrodes such as surface electrodes with hydrogel pads, subdermal needle electrodes, and EEG cups.&lt;br /&gt;
&lt;br /&gt;
=== Amplifiers ===&lt;br /&gt;
&lt;br /&gt;
An amplifier multiplies the input voltage to result in a greater output voltage (amplifier is the circuit and the difference between two input voltages).  Specifically, the amplifier functions as the power and converts alternating current to direct current, thereby flowing in only one direction, a resistor then increases the current flow by reducing the resistance.  The signal dictates the amount of the current, such that a greater signal allows for more current and more current results in more amplitude of the signal.&lt;br /&gt;
&lt;br /&gt;
=== Filtering ===&lt;br /&gt;
&lt;br /&gt;
Filters are used to determine the bandwidth while defining the specific content of the frequencies from the recorded signals, thereby attenuating some frequencies in the signal.  Filters can manipulate latency and amplitude.  There are different types of filters including high pass (attenuate high frequencies) and low pass filters (attenuate low frequencies).  High frequency filters will remove all frequencies above a set value (e.g., 5Hz), similarly, low frequency filters will remove frequencies below a set value (e.g., 5Hz).  Another type of filter is the notch filter which will remove one frequency such as the 60Hz, the background or external frequency that can interfere with the recorded neurophysiological signals as it is the frequency of the alternating current used in the power grid.&lt;br /&gt;
&lt;br /&gt;
=== Signal to Noise Ratio ===&lt;br /&gt;
&lt;br /&gt;
Signal to noise ratio refers to the electrical or neuruphysiological signal and the concurrent interference (noise).  Interference occurs both naturally and artificially.  For example, “noise” from the body (extraneous biological activity) or perisurgical such as the use of instrumentation or electrical interference.  The amplitude of the signal and the amplitude of the noise overlap given that the frequency content of noise contains a myriad of all frequencies and the specific frequency content of the signal would be within that range of all frequencies (Zouridakis and Papanicoloau, 2000).  Therefore, to increase specificity and detection of the electrical signal, the signal to noise ratio, the interference must be dampened which can be accomplished using filters as described above and the signal may be increased using averaging.&lt;br /&gt;
&lt;br /&gt;
=== Signal Averaging ===&lt;br /&gt;
&lt;br /&gt;
Evoked potentials elicited by electrical signals are small and a summation and average are thus necessary for detection of the signal (Zouridakis and Papanicoloau, 2000).  Specifically, the process of averaging is used to record evoked potentials, the electrical response in the brain to repeated sensory stimuli.  Given that the individual electrical responses in response to stimuli are small and therefore difficult to distinguish, and that background signals (e.g., ongoing and simultaneous brain activity, other electrical signals) can interfere with this detection, it is assumed that the signal of interest is embedded within all other ongoing electrical activity (noise), therefore summing and averaging improves (increases) the signal to noise ratio by reducing the noise amplitude when the signal to noise ratio (expressed in decibels) is low; the higher the number of trials that are averaged, the lower the noise.  &lt;br /&gt;
&lt;br /&gt;
The time (ms) just before and after the presentation of the stimulus is known as an epoch.  The averaging procedure involves repeated stimulation and signal recording such that each preceding response is added to the most recent (and at each time point), and those values are then divided.  That is, the epoch of each time point is added to all preceding ones and that sum is divided by the total number of epochs (trials).  For multiple channels recording simultaneously, each channel is averaged independently resulting in a separate evoked potential for each channel.   Evoked responses (e.g., sensory or motor) are averaged responses whereas electrically triggered EMG are nonaveraged.&lt;br /&gt;
&lt;br /&gt;
== Electrical Safety ==&lt;br /&gt;
&lt;br /&gt;
There are many sources of electrical activity in the operating theater.  The patient must be protected from the external sources of electrical activity.  One way the patient is protected is by the use of the ground wire (placed subcutaneously) in addition to the needle electrodes that are delivering stimulation.  Also, the neuromonitoring equipment is able to be quickly accessed and detached from the patient, specifically the electrodes can be removed from the cables and/or the cables can be detached from the computer (Moller, 1995).&lt;br /&gt;
&lt;br /&gt;
==References==&lt;br /&gt;
&lt;br /&gt;
Hodgkin AL and Huxley AF. &amp;quot;A quantitative description of membrane current and its application to conduction and excitation in nerve&amp;quot;. The Journal of Physiology 117.4 (1952): 500–544.&lt;br /&gt;
&lt;br /&gt;
Moller, A. (1995).  Intraoperative Neurophysiologic Monitoring.  Informa Healthcare.&lt;br /&gt;
&lt;br /&gt;
Pinel, J. P. J. (2014). Biopsychology. Harlow, Essex: Pearson Education Limited.&lt;br /&gt;
&lt;br /&gt;
Zouridakis, G. and Papanicoloau, A.C. (2000).  A Concise Guide to Intraoperative Monitoring.  CRC Press: Taylor and Francis Group.&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=184</id>
		<title>Basic Neurophysiology</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=184"/>
		<updated>2018-04-11T23:23:16Z</updated>

		<summary type="html">&lt;p&gt;Bpw: /* Propagated Neural Activity */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;br /&gt;
&#039;&#039;&#039;Neurophysiology&#039;&#039;&#039; is the study of the function of the nervous system.&lt;br /&gt;
&lt;br /&gt;
== Membrane Ion Channels ==&lt;br /&gt;
&lt;br /&gt;
All animal cells are enclosed in a plasma membrane, which separates its cytoplasm with the extracellular environment. Cell membrane has the structure of a lipid bilayer, with large molecules embedded in it. Concentration of ions are different across the cell membrane, with more sodium ions (Na+) and chloride ions (Cl-) outside the cell, and more potassium ions (K+) and negative charged protein molecules (A-) inside the cell. Selective ion channels at rest allow potassium ions (K+) cross the membrane easily, creating a voltage more negative inside the cell than outside, which is called resting membrane potential. The resting membrane potential of a neuron is about -70 mV.&lt;br /&gt;
&lt;br /&gt;
== Action Potential ==&lt;br /&gt;
&lt;br /&gt;
An action potential is the change in electrical potential associated with the passage of an impulse along the membrane of a muscle cell or nerve cell in response to a stimulus, which occurs as the electrical potential briefly (about 1ms) rises and falls (Hodgkin and Huxley).  Specifically, an action potential occurs when the threshold is reached (-65 mV) which activates the voltage-gated ion channels to open.  When the threshold is reached: Na+ channels open and Na+ rushes into the cell while K+ channels open slowly and K+ leaves the cell, the cell then becomes hyperpolarized (Pinel, 2017).  There are three phases of an action potential: the rising phase (Na+ and K+ channels open), repolarization (Na+ channels close), and hyperpolarization (K+ channels start to close).&lt;br /&gt;
&lt;br /&gt;
== Propagated Neural Activity ==&lt;br /&gt;
&lt;br /&gt;
An action potential is generated near the axon hillock when the threshold is reached (-65 mV), the signal is then propagated down (travels) the axon.  Active axonal conduction is due to the diffusion of Na+ into the cell which creates waves of depolarization whereas passive axonal conduction occurs as the signal travels down a myelinated axon along each segment, an action potential is generated at each node of Ranvier between the segments (Pinel, 2017) propagated from one node to the next (saltatory conduction).&lt;br /&gt;
&lt;br /&gt;
[[File:ion-channels.png|center|974px|560px]]&lt;br /&gt;
&lt;br /&gt;
Axons that are wrapped in myelin (fatty substance), which serves as insulation of the signal, have faster communication than unmyelinated axons.  The nodes of Ranvier are unmyelinated areas on the axon where the ions flow (e.g., Na+, K+).&lt;br /&gt;
&lt;br /&gt;
== Synaptic Transmission ==&lt;br /&gt;
&lt;br /&gt;
The process by which neurons communicate with each other is synaptic transmission which occurs across synapses using either electrical or chemical signals.  Electrical signaling occurs as an action potential travels from the pre- to the postsynaptic neuron via gap junctions.  However, most synaptic transmission involves chemical signals.  These chemicals are neurotransmitters, molecules which can function either directly (ionotropic) or indirectly via second messengers (metabotropic).  The steps in chemical neurotransmission are: synthesis of the neurotransmitter (in the soma), storage of the neurotransmitter in the vesicles, release into the synapse, binding to the receptor on the postsynaptic neuron, and inactivation of the neurotransmitter via reuptake or enzymatic degradation which terminates the action of the neurotransmitter in the synapse.&lt;br /&gt;
&lt;br /&gt;
== Recording Techniques ==&lt;br /&gt;
=== Electrodes  ===&lt;br /&gt;
&lt;br /&gt;
Electrodes are used to deliver and record electrical stimuli.  In Neurophysiology, electrodes deliver auditory, visual, and electrical stimuli, the amplitude, duration, and rate of which can be varied.  Various types of electrodes are used for recording electrophysiological activity from the scalp, nerves, and muscles (Zouridakis and Papanicoloau, 2000).  There are various types of electrodes such as surface electrodes with hydrogel pads, subdermal needle electrodes, and EEG cups.&lt;br /&gt;
&lt;br /&gt;
=== Amplifiers ===&lt;br /&gt;
&lt;br /&gt;
An amplifier multiplies the input voltage to result in a greater output voltage (amplifier is the circuit and the difference between two input voltages).  Specifically, the amplifier functions as the power and converts alternating current to direct current, thereby flowing in only one direction, a resistor then increases the current flow by reducing the resistance.  The signal dictates the amount of the current, such that a greater signal allows for more current and more current results in more amplitude of the signal.&lt;br /&gt;
&lt;br /&gt;
=== Filtering ===&lt;br /&gt;
&lt;br /&gt;
Filters are used to determine the bandwidth while defining the specific content of the frequencies from the recorded signals, thereby attenuating some frequencies in the signal.  Filters can manipulate latency and amplitude.  There are different types of filters including high pass (attenuate high frequencies) and low pass filters (attenuate low frequencies).  High frequency filters will remove all frequencies above a set value (e.g., 5Hz), similarly, low frequency filters will remove frequencies below a set value (e.g., 5Hz).  Another type of filter is the notch filter which will remove one frequency such as the 60Hz, the background or external frequency that can interfere with the recorded neurophysiological signals as it is the frequency of the alternating current used in the power grid.&lt;br /&gt;
&lt;br /&gt;
=== Signal to Noise Ratio ===&lt;br /&gt;
&lt;br /&gt;
Signal to noise ratio refers to the electrical or neuruphysiological signal and the concurrent interference (noise).  Interference occurs both naturally and artificially.  For example, “noise” from the body (extraneous biological activity) or perisurgical such as the use of instrumentation or electrical interference.  The amplitude of the signal and the amplitude of the noise overlap given that the frequency content of noise contains a myriad of all frequencies and the specific frequency content of the signal would be within that range of all frequencies (Zouridakis and Papanicoloau, 2000).  Therefore, to increase specificity and detection of the electrical signal, the signal to noise ratio, the interference must be dampened which can be accomplished using filters as described above and the signal may be increased using averaging.&lt;br /&gt;
&lt;br /&gt;
=== Signal Averaging ===&lt;br /&gt;
&lt;br /&gt;
Evoked potentials elicited by electrical signals are small and a summation and average are thus necessary for detection of the signal (Zouridakis and Papanicoloau, 2000).  Specifically, the process of averaging is used to record evoked potentials, the electrical response in the brain to repeated sensory stimuli.  Given that the individual electrical responses in response to stimuli are small and therefore difficult to distinguish, and that background signals (e.g., ongoing and simultaneous brain activity, other electrical signals) can interfere with this detection, it is assumed that the signal of interest is embedded within all other ongoing electrical activity (noise), therefore summing and averaging improves (increases) the signal to noise ratio by reducing the noise amplitude when the signal to noise ratio (expressed in decibels) is low; the higher the number of trials that are averaged, the lower the noise.  &lt;br /&gt;
&lt;br /&gt;
The time (ms) just before and after the presentation of the stimulus is known as an epoch.  The averaging procedure involves repeated stimulation and signal recording such that each preceding response is added to the most recent (and at each time point), and those values are then divided.  That is, the epoch of each time point is added to all preceding ones and that sum is divided by the total number of epochs (trials).  For multiple channels recording simultaneously, each channel is averaged independently resulting in a separate evoked potential for each channel.   Evoked responses (e.g., sensory or motor) are averaged responses whereas electrically triggered EMG are nonaveraged.&lt;br /&gt;
&lt;br /&gt;
== Electrical Safety ==&lt;br /&gt;
&lt;br /&gt;
There are many sources of electrical activity in the operating theater.  The patient must be protected from the external sources of electrical activity.  One way the patient is protected is by the use of the ground wire (placed subcutaneously) in addition to the needle electrodes that are delivering stimulation.  Also, the neuromonitoring equipment is able to be quickly accessed and detached from the patient, specifically the electrodes can be removed from the cables and/or the cables can be detached from the computer (Moller, 1995).&lt;br /&gt;
&lt;br /&gt;
==References==&lt;br /&gt;
&lt;br /&gt;
Hodgkin AL and Huxley AF. &amp;quot;A quantitative description of membrane current and its application to conduction and excitation in nerve&amp;quot;. The Journal of Physiology 117.4 (1952): 500–544.&lt;br /&gt;
&lt;br /&gt;
Moller, A. (1995).  Intraoperative Neurophysiologic Monitoring.  Informa Healthcare.&lt;br /&gt;
&lt;br /&gt;
Pinel, J. P. J. (2014). Biopsychology. Harlow, Essex: Pearson Education Limited.&lt;br /&gt;
&lt;br /&gt;
Zouridakis, G. and Papanicoloau, A.C. (2000).  A Concise Guide to Intraoperative Monitoring.  CRC Press: Taylor and Francis Group.&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=183</id>
		<title>Basic Neurophysiology</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=183"/>
		<updated>2018-04-11T23:22:48Z</updated>

		<summary type="html">&lt;p&gt;Bpw: /* Propagated Neural Activity */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;br /&gt;
&#039;&#039;&#039;Neurophysiology&#039;&#039;&#039; is the study of the function of the nervous system.&lt;br /&gt;
&lt;br /&gt;
== Membrane Ion Channels ==&lt;br /&gt;
&lt;br /&gt;
All animal cells are enclosed in a plasma membrane, which separates its cytoplasm with the extracellular environment. Cell membrane has the structure of a lipid bilayer, with large molecules embedded in it. Concentration of ions are different across the cell membrane, with more sodium ions (Na+) and chloride ions (Cl-) outside the cell, and more potassium ions (K+) and negative charged protein molecules (A-) inside the cell. Selective ion channels at rest allow potassium ions (K+) cross the membrane easily, creating a voltage more negative inside the cell than outside, which is called resting membrane potential. The resting membrane potential of a neuron is about -70 mV.&lt;br /&gt;
&lt;br /&gt;
== Action Potential ==&lt;br /&gt;
&lt;br /&gt;
An action potential is the change in electrical potential associated with the passage of an impulse along the membrane of a muscle cell or nerve cell in response to a stimulus, which occurs as the electrical potential briefly (about 1ms) rises and falls (Hodgkin and Huxley).  Specifically, an action potential occurs when the threshold is reached (-65 mV) which activates the voltage-gated ion channels to open.  When the threshold is reached: Na+ channels open and Na+ rushes into the cell while K+ channels open slowly and K+ leaves the cell, the cell then becomes hyperpolarized (Pinel, 2017).  There are three phases of an action potential: the rising phase (Na+ and K+ channels open), repolarization (Na+ channels close), and hyperpolarization (K+ channels start to close).&lt;br /&gt;
&lt;br /&gt;
== Propagated Neural Activity ==&lt;br /&gt;
&lt;br /&gt;
An action potential is generated near the axon hillock when the threshold is reached (-65 mV), the signal is then propagated down (travels) the axon.  Active axonal conduction is due to the diffusion of Na+ into the cell which creates waves of depolarization whereas passive axonal conduction occurs as the signal travels down a myelinated axon along each segment, an action potential is generated at each node of Ranvier between the segments (Pinel, 2017) propagated from one node to the next (saltatory conduction).&lt;br /&gt;
&lt;br /&gt;
[[File:ion-channels.png|center|730px|420px]]&lt;br /&gt;
&lt;br /&gt;
Axons that are wrapped in myelin (fatty substance), which serves as insulation of the signal, have faster communication than unmyelinated axons.  The nodes of Ranvier are unmyelinated areas on the axon where the ions flow (e.g., Na+, K+).&lt;br /&gt;
&lt;br /&gt;
== Synaptic Transmission ==&lt;br /&gt;
&lt;br /&gt;
The process by which neurons communicate with each other is synaptic transmission which occurs across synapses using either electrical or chemical signals.  Electrical signaling occurs as an action potential travels from the pre- to the postsynaptic neuron via gap junctions.  However, most synaptic transmission involves chemical signals.  These chemicals are neurotransmitters, molecules which can function either directly (ionotropic) or indirectly via second messengers (metabotropic).  The steps in chemical neurotransmission are: synthesis of the neurotransmitter (in the soma), storage of the neurotransmitter in the vesicles, release into the synapse, binding to the receptor on the postsynaptic neuron, and inactivation of the neurotransmitter via reuptake or enzymatic degradation which terminates the action of the neurotransmitter in the synapse.&lt;br /&gt;
&lt;br /&gt;
== Recording Techniques ==&lt;br /&gt;
=== Electrodes  ===&lt;br /&gt;
&lt;br /&gt;
Electrodes are used to deliver and record electrical stimuli.  In Neurophysiology, electrodes deliver auditory, visual, and electrical stimuli, the amplitude, duration, and rate of which can be varied.  Various types of electrodes are used for recording electrophysiological activity from the scalp, nerves, and muscles (Zouridakis and Papanicoloau, 2000).  There are various types of electrodes such as surface electrodes with hydrogel pads, subdermal needle electrodes, and EEG cups.&lt;br /&gt;
&lt;br /&gt;
=== Amplifiers ===&lt;br /&gt;
&lt;br /&gt;
An amplifier multiplies the input voltage to result in a greater output voltage (amplifier is the circuit and the difference between two input voltages).  Specifically, the amplifier functions as the power and converts alternating current to direct current, thereby flowing in only one direction, a resistor then increases the current flow by reducing the resistance.  The signal dictates the amount of the current, such that a greater signal allows for more current and more current results in more amplitude of the signal.&lt;br /&gt;
&lt;br /&gt;
=== Filtering ===&lt;br /&gt;
&lt;br /&gt;
Filters are used to determine the bandwidth while defining the specific content of the frequencies from the recorded signals, thereby attenuating some frequencies in the signal.  Filters can manipulate latency and amplitude.  There are different types of filters including high pass (attenuate high frequencies) and low pass filters (attenuate low frequencies).  High frequency filters will remove all frequencies above a set value (e.g., 5Hz), similarly, low frequency filters will remove frequencies below a set value (e.g., 5Hz).  Another type of filter is the notch filter which will remove one frequency such as the 60Hz, the background or external frequency that can interfere with the recorded neurophysiological signals as it is the frequency of the alternating current used in the power grid.&lt;br /&gt;
&lt;br /&gt;
=== Signal to Noise Ratio ===&lt;br /&gt;
&lt;br /&gt;
Signal to noise ratio refers to the electrical or neuruphysiological signal and the concurrent interference (noise).  Interference occurs both naturally and artificially.  For example, “noise” from the body (extraneous biological activity) or perisurgical such as the use of instrumentation or electrical interference.  The amplitude of the signal and the amplitude of the noise overlap given that the frequency content of noise contains a myriad of all frequencies and the specific frequency content of the signal would be within that range of all frequencies (Zouridakis and Papanicoloau, 2000).  Therefore, to increase specificity and detection of the electrical signal, the signal to noise ratio, the interference must be dampened which can be accomplished using filters as described above and the signal may be increased using averaging.&lt;br /&gt;
&lt;br /&gt;
=== Signal Averaging ===&lt;br /&gt;
&lt;br /&gt;
Evoked potentials elicited by electrical signals are small and a summation and average are thus necessary for detection of the signal (Zouridakis and Papanicoloau, 2000).  Specifically, the process of averaging is used to record evoked potentials, the electrical response in the brain to repeated sensory stimuli.  Given that the individual electrical responses in response to stimuli are small and therefore difficult to distinguish, and that background signals (e.g., ongoing and simultaneous brain activity, other electrical signals) can interfere with this detection, it is assumed that the signal of interest is embedded within all other ongoing electrical activity (noise), therefore summing and averaging improves (increases) the signal to noise ratio by reducing the noise amplitude when the signal to noise ratio (expressed in decibels) is low; the higher the number of trials that are averaged, the lower the noise.  &lt;br /&gt;
&lt;br /&gt;
The time (ms) just before and after the presentation of the stimulus is known as an epoch.  The averaging procedure involves repeated stimulation and signal recording such that each preceding response is added to the most recent (and at each time point), and those values are then divided.  That is, the epoch of each time point is added to all preceding ones and that sum is divided by the total number of epochs (trials).  For multiple channels recording simultaneously, each channel is averaged independently resulting in a separate evoked potential for each channel.   Evoked responses (e.g., sensory or motor) are averaged responses whereas electrically triggered EMG are nonaveraged.&lt;br /&gt;
&lt;br /&gt;
== Electrical Safety ==&lt;br /&gt;
&lt;br /&gt;
There are many sources of electrical activity in the operating theater.  The patient must be protected from the external sources of electrical activity.  One way the patient is protected is by the use of the ground wire (placed subcutaneously) in addition to the needle electrodes that are delivering stimulation.  Also, the neuromonitoring equipment is able to be quickly accessed and detached from the patient, specifically the electrodes can be removed from the cables and/or the cables can be detached from the computer (Moller, 1995).&lt;br /&gt;
&lt;br /&gt;
==References==&lt;br /&gt;
&lt;br /&gt;
Hodgkin AL and Huxley AF. &amp;quot;A quantitative description of membrane current and its application to conduction and excitation in nerve&amp;quot;. The Journal of Physiology 117.4 (1952): 500–544.&lt;br /&gt;
&lt;br /&gt;
Moller, A. (1995).  Intraoperative Neurophysiologic Monitoring.  Informa Healthcare.&lt;br /&gt;
&lt;br /&gt;
Pinel, J. P. J. (2014). Biopsychology. Harlow, Essex: Pearson Education Limited.&lt;br /&gt;
&lt;br /&gt;
Zouridakis, G. and Papanicoloau, A.C. (2000).  A Concise Guide to Intraoperative Monitoring.  CRC Press: Taylor and Francis Group.&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=File:Ion-channels.png&amp;diff=182</id>
		<title>File:Ion-channels.png</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=File:Ion-channels.png&amp;diff=182"/>
		<updated>2018-04-11T23:18:30Z</updated>

		<summary type="html">&lt;p&gt;Bpw: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=181</id>
		<title>Basic Neurophysiology</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=181"/>
		<updated>2018-04-11T23:16:54Z</updated>

		<summary type="html">&lt;p&gt;Bpw: /* Propagated Neural Activity */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;br /&gt;
&#039;&#039;&#039;Neurophysiology&#039;&#039;&#039; is the study of the function of the nervous system.&lt;br /&gt;
&lt;br /&gt;
== Membrane Ion Channels ==&lt;br /&gt;
&lt;br /&gt;
All animal cells are enclosed in a plasma membrane, which separates its cytoplasm with the extracellular environment. Cell membrane has the structure of a lipid bilayer, with large molecules embedded in it. Concentration of ions are different across the cell membrane, with more sodium ions (Na+) and chloride ions (Cl-) outside the cell, and more potassium ions (K+) and negative charged protein molecules (A-) inside the cell. Selective ion channels at rest allow potassium ions (K+) cross the membrane easily, creating a voltage more negative inside the cell than outside, which is called resting membrane potential. The resting membrane potential of a neuron is about -70 mV.&lt;br /&gt;
&lt;br /&gt;
== Action Potential ==&lt;br /&gt;
&lt;br /&gt;
An action potential is the change in electrical potential associated with the passage of an impulse along the membrane of a muscle cell or nerve cell in response to a stimulus, which occurs as the electrical potential briefly (about 1ms) rises and falls (Hodgkin and Huxley).  Specifically, an action potential occurs when the threshold is reached (-65 mV) which activates the voltage-gated ion channels to open.  When the threshold is reached: Na+ channels open and Na+ rushes into the cell while K+ channels open slowly and K+ leaves the cell, the cell then becomes hyperpolarized (Pinel, 2017).  There are three phases of an action potential: the rising phase (Na+ and K+ channels open), repolarization (Na+ channels close), and hyperpolarization (K+ channels start to close).&lt;br /&gt;
&lt;br /&gt;
== Propagated Neural Activity ==&lt;br /&gt;
&lt;br /&gt;
An action potential is generated near the axon hillock when the threshold is reached (-65 mV), the signal is then propagated down (travels) the axon.  Active axonal conduction is due to the diffusion of Na+ into the cell which creates waves of depolarization whereas passive axonal conduction occurs as the signal travels down a myelinated axon along each segment, an action potential is generated at each node of Ranvier between the segments (Pinel, 2017) propagated from one node to the next (saltatory conduction).&lt;br /&gt;
&lt;br /&gt;
[[File:ion-channels.png]]&lt;br /&gt;
&lt;br /&gt;
Axons that are wrapped in myelin (fatty substance), which serves as insulation of the signal, have faster communication than unmyelinated axons.  The nodes of Ranvier are unmyelinated areas on the axon where the ions flow (e.g., Na+, K+).&lt;br /&gt;
&lt;br /&gt;
== Synaptic Transmission ==&lt;br /&gt;
&lt;br /&gt;
The process by which neurons communicate with each other is synaptic transmission which occurs across synapses using either electrical or chemical signals.  Electrical signaling occurs as an action potential travels from the pre- to the postsynaptic neuron via gap junctions.  However, most synaptic transmission involves chemical signals.  These chemicals are neurotransmitters, molecules which can function either directly (ionotropic) or indirectly via second messengers (metabotropic).  The steps in chemical neurotransmission are: synthesis of the neurotransmitter (in the soma), storage of the neurotransmitter in the vesicles, release into the synapse, binding to the receptor on the postsynaptic neuron, and inactivation of the neurotransmitter via reuptake or enzymatic degradation which terminates the action of the neurotransmitter in the synapse.&lt;br /&gt;
&lt;br /&gt;
== Recording Techniques ==&lt;br /&gt;
=== Electrodes  ===&lt;br /&gt;
&lt;br /&gt;
Electrodes are used to deliver and record electrical stimuli.  In Neurophysiology, electrodes deliver auditory, visual, and electrical stimuli, the amplitude, duration, and rate of which can be varied.  Various types of electrodes are used for recording electrophysiological activity from the scalp, nerves, and muscles (Zouridakis and Papanicoloau, 2000).  There are various types of electrodes such as surface electrodes with hydrogel pads, subdermal needle electrodes, and EEG cups.&lt;br /&gt;
&lt;br /&gt;
=== Amplifiers ===&lt;br /&gt;
&lt;br /&gt;
An amplifier multiplies the input voltage to result in a greater output voltage (amplifier is the circuit and the difference between two input voltages).  Specifically, the amplifier functions as the power and converts alternating current to direct current, thereby flowing in only one direction, a resistor then increases the current flow by reducing the resistance.  The signal dictates the amount of the current, such that a greater signal allows for more current and more current results in more amplitude of the signal.&lt;br /&gt;
&lt;br /&gt;
=== Filtering ===&lt;br /&gt;
&lt;br /&gt;
Filters are used to determine the bandwidth while defining the specific content of the frequencies from the recorded signals, thereby attenuating some frequencies in the signal.  Filters can manipulate latency and amplitude.  There are different types of filters including high pass (attenuate high frequencies) and low pass filters (attenuate low frequencies).  High frequency filters will remove all frequencies above a set value (e.g., 5Hz), similarly, low frequency filters will remove frequencies below a set value (e.g., 5Hz).  Another type of filter is the notch filter which will remove one frequency such as the 60Hz, the background or external frequency that can interfere with the recorded neurophysiological signals as it is the frequency of the alternating current used in the power grid.&lt;br /&gt;
&lt;br /&gt;
=== Signal to Noise Ratio ===&lt;br /&gt;
&lt;br /&gt;
Signal to noise ratio refers to the electrical or neuruphysiological signal and the concurrent interference (noise).  Interference occurs both naturally and artificially.  For example, “noise” from the body (extraneous biological activity) or perisurgical such as the use of instrumentation or electrical interference.  The amplitude of the signal and the amplitude of the noise overlap given that the frequency content of noise contains a myriad of all frequencies and the specific frequency content of the signal would be within that range of all frequencies (Zouridakis and Papanicoloau, 2000).  Therefore, to increase specificity and detection of the electrical signal, the signal to noise ratio, the interference must be dampened which can be accomplished using filters as described above and the signal may be increased using averaging.&lt;br /&gt;
&lt;br /&gt;
=== Signal Averaging ===&lt;br /&gt;
&lt;br /&gt;
Evoked potentials elicited by electrical signals are small and a summation and average are thus necessary for detection of the signal (Zouridakis and Papanicoloau, 2000).  Specifically, the process of averaging is used to record evoked potentials, the electrical response in the brain to repeated sensory stimuli.  Given that the individual electrical responses in response to stimuli are small and therefore difficult to distinguish, and that background signals (e.g., ongoing and simultaneous brain activity, other electrical signals) can interfere with this detection, it is assumed that the signal of interest is embedded within all other ongoing electrical activity (noise), therefore summing and averaging improves (increases) the signal to noise ratio by reducing the noise amplitude when the signal to noise ratio (expressed in decibels) is low; the higher the number of trials that are averaged, the lower the noise.  &lt;br /&gt;
&lt;br /&gt;
The time (ms) just before and after the presentation of the stimulus is known as an epoch.  The averaging procedure involves repeated stimulation and signal recording such that each preceding response is added to the most recent (and at each time point), and those values are then divided.  That is, the epoch of each time point is added to all preceding ones and that sum is divided by the total number of epochs (trials).  For multiple channels recording simultaneously, each channel is averaged independently resulting in a separate evoked potential for each channel.   Evoked responses (e.g., sensory or motor) are averaged responses whereas electrically triggered EMG are nonaveraged.&lt;br /&gt;
&lt;br /&gt;
== Electrical Safety ==&lt;br /&gt;
&lt;br /&gt;
There are many sources of electrical activity in the operating theater.  The patient must be protected from the external sources of electrical activity.  One way the patient is protected is by the use of the ground wire (placed subcutaneously) in addition to the needle electrodes that are delivering stimulation.  Also, the neuromonitoring equipment is able to be quickly accessed and detached from the patient, specifically the electrodes can be removed from the cables and/or the cables can be detached from the computer (Moller, 1995).&lt;br /&gt;
&lt;br /&gt;
==References==&lt;br /&gt;
&lt;br /&gt;
Hodgkin AL and Huxley AF. &amp;quot;A quantitative description of membrane current and its application to conduction and excitation in nerve&amp;quot;. The Journal of Physiology 117.4 (1952): 500–544.&lt;br /&gt;
&lt;br /&gt;
Moller, A. (1995).  Intraoperative Neurophysiologic Monitoring.  Informa Healthcare.&lt;br /&gt;
&lt;br /&gt;
Pinel, J. P. J. (2014). Biopsychology. Harlow, Essex: Pearson Education Limited.&lt;br /&gt;
&lt;br /&gt;
Zouridakis, G. and Papanicoloau, A.C. (2000).  A Concise Guide to Intraoperative Monitoring.  CRC Press: Taylor and Francis Group.&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=180</id>
		<title>Basic Neurophysiology</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=180"/>
		<updated>2018-04-11T23:13:14Z</updated>

		<summary type="html">&lt;p&gt;Bpw: /* References */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;br /&gt;
&#039;&#039;&#039;Neurophysiology&#039;&#039;&#039; is the study of the function of the nervous system.&lt;br /&gt;
&lt;br /&gt;
== Membrane Ion Channels ==&lt;br /&gt;
&lt;br /&gt;
All animal cells are enclosed in a plasma membrane, which separates its cytoplasm with the extracellular environment. Cell membrane has the structure of a lipid bilayer, with large molecules embedded in it. Concentration of ions are different across the cell membrane, with more sodium ions (Na+) and chloride ions (Cl-) outside the cell, and more potassium ions (K+) and negative charged protein molecules (A-) inside the cell. Selective ion channels at rest allow potassium ions (K+) cross the membrane easily, creating a voltage more negative inside the cell than outside, which is called resting membrane potential. The resting membrane potential of a neuron is about -70 mV.&lt;br /&gt;
&lt;br /&gt;
== Action Potential ==&lt;br /&gt;
&lt;br /&gt;
An action potential is the change in electrical potential associated with the passage of an impulse along the membrane of a muscle cell or nerve cell in response to a stimulus, which occurs as the electrical potential briefly (about 1ms) rises and falls (Hodgkin and Huxley).  Specifically, an action potential occurs when the threshold is reached (-65 mV) which activates the voltage-gated ion channels to open.  When the threshold is reached: Na+ channels open and Na+ rushes into the cell while K+ channels open slowly and K+ leaves the cell, the cell then becomes hyperpolarized (Pinel, 2017).  There are three phases of an action potential: the rising phase (Na+ and K+ channels open), repolarization (Na+ channels close), and hyperpolarization (K+ channels start to close).&lt;br /&gt;
&lt;br /&gt;
== Propagated Neural Activity ==&lt;br /&gt;
&lt;br /&gt;
An action potential is generated near the axon hillock when the threshold is reached (-65 mV), the signal is then propagated down (travels) the axon.  Active axonal conduction is due to the diffusion of Na+ into the cell which creates waves of depolarization whereas passive axonal conduction occurs as the signal travels down a myelinated axon along each segment, an action potential is generated at each node of Ranvier between the segments (Pinel, 2017) propagated from one node to the next (saltatory conduction).&lt;br /&gt;
&lt;br /&gt;
Axons that are wrapped in myelin (fatty substance), which serves as insulation of the signal, have faster communication than unmyelinated axons.  The nodes of Ranvier are unmyelinated areas on the axon where the ions flow (e.g., Na+, K+).&lt;br /&gt;
&lt;br /&gt;
== Synaptic Transmission ==&lt;br /&gt;
&lt;br /&gt;
The process by which neurons communicate with each other is synaptic transmission which occurs across synapses using either electrical or chemical signals.  Electrical signaling occurs as an action potential travels from the pre- to the postsynaptic neuron via gap junctions.  However, most synaptic transmission involves chemical signals.  These chemicals are neurotransmitters, molecules which can function either directly (ionotropic) or indirectly via second messengers (metabotropic).  The steps in chemical neurotransmission are: synthesis of the neurotransmitter (in the soma), storage of the neurotransmitter in the vesicles, release into the synapse, binding to the receptor on the postsynaptic neuron, and inactivation of the neurotransmitter via reuptake or enzymatic degradation which terminates the action of the neurotransmitter in the synapse.&lt;br /&gt;
&lt;br /&gt;
== Recording Techniques ==&lt;br /&gt;
=== Electrodes  ===&lt;br /&gt;
&lt;br /&gt;
Electrodes are used to deliver and record electrical stimuli.  In Neurophysiology, electrodes deliver auditory, visual, and electrical stimuli, the amplitude, duration, and rate of which can be varied.  Various types of electrodes are used for recording electrophysiological activity from the scalp, nerves, and muscles (Zouridakis and Papanicoloau, 2000).  There are various types of electrodes such as surface electrodes with hydrogel pads, subdermal needle electrodes, and EEG cups.&lt;br /&gt;
&lt;br /&gt;
=== Amplifiers ===&lt;br /&gt;
&lt;br /&gt;
An amplifier multiplies the input voltage to result in a greater output voltage (amplifier is the circuit and the difference between two input voltages).  Specifically, the amplifier functions as the power and converts alternating current to direct current, thereby flowing in only one direction, a resistor then increases the current flow by reducing the resistance.  The signal dictates the amount of the current, such that a greater signal allows for more current and more current results in more amplitude of the signal.&lt;br /&gt;
&lt;br /&gt;
=== Filtering ===&lt;br /&gt;
&lt;br /&gt;
Filters are used to determine the bandwidth while defining the specific content of the frequencies from the recorded signals, thereby attenuating some frequencies in the signal.  Filters can manipulate latency and amplitude.  There are different types of filters including high pass (attenuate high frequencies) and low pass filters (attenuate low frequencies).  High frequency filters will remove all frequencies above a set value (e.g., 5Hz), similarly, low frequency filters will remove frequencies below a set value (e.g., 5Hz).  Another type of filter is the notch filter which will remove one frequency such as the 60Hz, the background or external frequency that can interfere with the recorded neurophysiological signals as it is the frequency of the alternating current used in the power grid.&lt;br /&gt;
&lt;br /&gt;
=== Signal to Noise Ratio ===&lt;br /&gt;
&lt;br /&gt;
Signal to noise ratio refers to the electrical or neuruphysiological signal and the concurrent interference (noise).  Interference occurs both naturally and artificially.  For example, “noise” from the body (extraneous biological activity) or perisurgical such as the use of instrumentation or electrical interference.  The amplitude of the signal and the amplitude of the noise overlap given that the frequency content of noise contains a myriad of all frequencies and the specific frequency content of the signal would be within that range of all frequencies (Zouridakis and Papanicoloau, 2000).  Therefore, to increase specificity and detection of the electrical signal, the signal to noise ratio, the interference must be dampened which can be accomplished using filters as described above and the signal may be increased using averaging.&lt;br /&gt;
&lt;br /&gt;
=== Signal Averaging ===&lt;br /&gt;
&lt;br /&gt;
Evoked potentials elicited by electrical signals are small and a summation and average are thus necessary for detection of the signal (Zouridakis and Papanicoloau, 2000).  Specifically, the process of averaging is used to record evoked potentials, the electrical response in the brain to repeated sensory stimuli.  Given that the individual electrical responses in response to stimuli are small and therefore difficult to distinguish, and that background signals (e.g., ongoing and simultaneous brain activity, other electrical signals) can interfere with this detection, it is assumed that the signal of interest is embedded within all other ongoing electrical activity (noise), therefore summing and averaging improves (increases) the signal to noise ratio by reducing the noise amplitude when the signal to noise ratio (expressed in decibels) is low; the higher the number of trials that are averaged, the lower the noise.  &lt;br /&gt;
&lt;br /&gt;
The time (ms) just before and after the presentation of the stimulus is known as an epoch.  The averaging procedure involves repeated stimulation and signal recording such that each preceding response is added to the most recent (and at each time point), and those values are then divided.  That is, the epoch of each time point is added to all preceding ones and that sum is divided by the total number of epochs (trials).  For multiple channels recording simultaneously, each channel is averaged independently resulting in a separate evoked potential for each channel.   Evoked responses (e.g., sensory or motor) are averaged responses whereas electrically triggered EMG are nonaveraged.&lt;br /&gt;
&lt;br /&gt;
== Electrical Safety ==&lt;br /&gt;
&lt;br /&gt;
There are many sources of electrical activity in the operating theater.  The patient must be protected from the external sources of electrical activity.  One way the patient is protected is by the use of the ground wire (placed subcutaneously) in addition to the needle electrodes that are delivering stimulation.  Also, the neuromonitoring equipment is able to be quickly accessed and detached from the patient, specifically the electrodes can be removed from the cables and/or the cables can be detached from the computer (Moller, 1995).&lt;br /&gt;
&lt;br /&gt;
==References==&lt;br /&gt;
&lt;br /&gt;
Hodgkin AL and Huxley AF. &amp;quot;A quantitative description of membrane current and its application to conduction and excitation in nerve&amp;quot;. The Journal of Physiology 117.4 (1952): 500–544.&lt;br /&gt;
&lt;br /&gt;
Moller, A. (1995).  Intraoperative Neurophysiologic Monitoring.  Informa Healthcare.&lt;br /&gt;
&lt;br /&gt;
Pinel, J. P. J. (2014). Biopsychology. Harlow, Essex: Pearson Education Limited.&lt;br /&gt;
&lt;br /&gt;
Zouridakis, G. and Papanicoloau, A.C. (2000).  A Concise Guide to Intraoperative Monitoring.  CRC Press: Taylor and Francis Group.&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=179</id>
		<title>Basic Neurophysiology</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=179"/>
		<updated>2018-04-11T23:12:47Z</updated>

		<summary type="html">&lt;p&gt;Bpw: /* Electrical Safety */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;br /&gt;
&#039;&#039;&#039;Neurophysiology&#039;&#039;&#039; is the study of the function of the nervous system.&lt;br /&gt;
&lt;br /&gt;
== Membrane Ion Channels ==&lt;br /&gt;
&lt;br /&gt;
All animal cells are enclosed in a plasma membrane, which separates its cytoplasm with the extracellular environment. Cell membrane has the structure of a lipid bilayer, with large molecules embedded in it. Concentration of ions are different across the cell membrane, with more sodium ions (Na+) and chloride ions (Cl-) outside the cell, and more potassium ions (K+) and negative charged protein molecules (A-) inside the cell. Selective ion channels at rest allow potassium ions (K+) cross the membrane easily, creating a voltage more negative inside the cell than outside, which is called resting membrane potential. The resting membrane potential of a neuron is about -70 mV.&lt;br /&gt;
&lt;br /&gt;
== Action Potential ==&lt;br /&gt;
&lt;br /&gt;
An action potential is the change in electrical potential associated with the passage of an impulse along the membrane of a muscle cell or nerve cell in response to a stimulus, which occurs as the electrical potential briefly (about 1ms) rises and falls (Hodgkin and Huxley).  Specifically, an action potential occurs when the threshold is reached (-65 mV) which activates the voltage-gated ion channels to open.  When the threshold is reached: Na+ channels open and Na+ rushes into the cell while K+ channels open slowly and K+ leaves the cell, the cell then becomes hyperpolarized (Pinel, 2017).  There are three phases of an action potential: the rising phase (Na+ and K+ channels open), repolarization (Na+ channels close), and hyperpolarization (K+ channels start to close).&lt;br /&gt;
&lt;br /&gt;
== Propagated Neural Activity ==&lt;br /&gt;
&lt;br /&gt;
An action potential is generated near the axon hillock when the threshold is reached (-65 mV), the signal is then propagated down (travels) the axon.  Active axonal conduction is due to the diffusion of Na+ into the cell which creates waves of depolarization whereas passive axonal conduction occurs as the signal travels down a myelinated axon along each segment, an action potential is generated at each node of Ranvier between the segments (Pinel, 2017) propagated from one node to the next (saltatory conduction).&lt;br /&gt;
&lt;br /&gt;
Axons that are wrapped in myelin (fatty substance), which serves as insulation of the signal, have faster communication than unmyelinated axons.  The nodes of Ranvier are unmyelinated areas on the axon where the ions flow (e.g., Na+, K+).&lt;br /&gt;
&lt;br /&gt;
== Synaptic Transmission ==&lt;br /&gt;
&lt;br /&gt;
The process by which neurons communicate with each other is synaptic transmission which occurs across synapses using either electrical or chemical signals.  Electrical signaling occurs as an action potential travels from the pre- to the postsynaptic neuron via gap junctions.  However, most synaptic transmission involves chemical signals.  These chemicals are neurotransmitters, molecules which can function either directly (ionotropic) or indirectly via second messengers (metabotropic).  The steps in chemical neurotransmission are: synthesis of the neurotransmitter (in the soma), storage of the neurotransmitter in the vesicles, release into the synapse, binding to the receptor on the postsynaptic neuron, and inactivation of the neurotransmitter via reuptake or enzymatic degradation which terminates the action of the neurotransmitter in the synapse.&lt;br /&gt;
&lt;br /&gt;
== Recording Techniques ==&lt;br /&gt;
=== Electrodes  ===&lt;br /&gt;
&lt;br /&gt;
Electrodes are used to deliver and record electrical stimuli.  In Neurophysiology, electrodes deliver auditory, visual, and electrical stimuli, the amplitude, duration, and rate of which can be varied.  Various types of electrodes are used for recording electrophysiological activity from the scalp, nerves, and muscles (Zouridakis and Papanicoloau, 2000).  There are various types of electrodes such as surface electrodes with hydrogel pads, subdermal needle electrodes, and EEG cups.&lt;br /&gt;
&lt;br /&gt;
=== Amplifiers ===&lt;br /&gt;
&lt;br /&gt;
An amplifier multiplies the input voltage to result in a greater output voltage (amplifier is the circuit and the difference between two input voltages).  Specifically, the amplifier functions as the power and converts alternating current to direct current, thereby flowing in only one direction, a resistor then increases the current flow by reducing the resistance.  The signal dictates the amount of the current, such that a greater signal allows for more current and more current results in more amplitude of the signal.&lt;br /&gt;
&lt;br /&gt;
=== Filtering ===&lt;br /&gt;
&lt;br /&gt;
Filters are used to determine the bandwidth while defining the specific content of the frequencies from the recorded signals, thereby attenuating some frequencies in the signal.  Filters can manipulate latency and amplitude.  There are different types of filters including high pass (attenuate high frequencies) and low pass filters (attenuate low frequencies).  High frequency filters will remove all frequencies above a set value (e.g., 5Hz), similarly, low frequency filters will remove frequencies below a set value (e.g., 5Hz).  Another type of filter is the notch filter which will remove one frequency such as the 60Hz, the background or external frequency that can interfere with the recorded neurophysiological signals as it is the frequency of the alternating current used in the power grid.&lt;br /&gt;
&lt;br /&gt;
=== Signal to Noise Ratio ===&lt;br /&gt;
&lt;br /&gt;
Signal to noise ratio refers to the electrical or neuruphysiological signal and the concurrent interference (noise).  Interference occurs both naturally and artificially.  For example, “noise” from the body (extraneous biological activity) or perisurgical such as the use of instrumentation or electrical interference.  The amplitude of the signal and the amplitude of the noise overlap given that the frequency content of noise contains a myriad of all frequencies and the specific frequency content of the signal would be within that range of all frequencies (Zouridakis and Papanicoloau, 2000).  Therefore, to increase specificity and detection of the electrical signal, the signal to noise ratio, the interference must be dampened which can be accomplished using filters as described above and the signal may be increased using averaging.&lt;br /&gt;
&lt;br /&gt;
=== Signal Averaging ===&lt;br /&gt;
&lt;br /&gt;
Evoked potentials elicited by electrical signals are small and a summation and average are thus necessary for detection of the signal (Zouridakis and Papanicoloau, 2000).  Specifically, the process of averaging is used to record evoked potentials, the electrical response in the brain to repeated sensory stimuli.  Given that the individual electrical responses in response to stimuli are small and therefore difficult to distinguish, and that background signals (e.g., ongoing and simultaneous brain activity, other electrical signals) can interfere with this detection, it is assumed that the signal of interest is embedded within all other ongoing electrical activity (noise), therefore summing and averaging improves (increases) the signal to noise ratio by reducing the noise amplitude when the signal to noise ratio (expressed in decibels) is low; the higher the number of trials that are averaged, the lower the noise.  &lt;br /&gt;
&lt;br /&gt;
The time (ms) just before and after the presentation of the stimulus is known as an epoch.  The averaging procedure involves repeated stimulation and signal recording such that each preceding response is added to the most recent (and at each time point), and those values are then divided.  That is, the epoch of each time point is added to all preceding ones and that sum is divided by the total number of epochs (trials).  For multiple channels recording simultaneously, each channel is averaged independently resulting in a separate evoked potential for each channel.   Evoked responses (e.g., sensory or motor) are averaged responses whereas electrically triggered EMG are nonaveraged.&lt;br /&gt;
&lt;br /&gt;
== Electrical Safety ==&lt;br /&gt;
&lt;br /&gt;
There are many sources of electrical activity in the operating theater.  The patient must be protected from the external sources of electrical activity.  One way the patient is protected is by the use of the ground wire (placed subcutaneously) in addition to the needle electrodes that are delivering stimulation.  Also, the neuromonitoring equipment is able to be quickly accessed and detached from the patient, specifically the electrodes can be removed from the cables and/or the cables can be detached from the computer (Moller, 1995).&lt;br /&gt;
&lt;br /&gt;
==References==&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=178</id>
		<title>Basic Neurophysiology</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=178"/>
		<updated>2018-04-11T23:12:28Z</updated>

		<summary type="html">&lt;p&gt;Bpw: /* Signal Averaging */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;br /&gt;
&#039;&#039;&#039;Neurophysiology&#039;&#039;&#039; is the study of the function of the nervous system.&lt;br /&gt;
&lt;br /&gt;
== Membrane Ion Channels ==&lt;br /&gt;
&lt;br /&gt;
All animal cells are enclosed in a plasma membrane, which separates its cytoplasm with the extracellular environment. Cell membrane has the structure of a lipid bilayer, with large molecules embedded in it. Concentration of ions are different across the cell membrane, with more sodium ions (Na+) and chloride ions (Cl-) outside the cell, and more potassium ions (K+) and negative charged protein molecules (A-) inside the cell. Selective ion channels at rest allow potassium ions (K+) cross the membrane easily, creating a voltage more negative inside the cell than outside, which is called resting membrane potential. The resting membrane potential of a neuron is about -70 mV.&lt;br /&gt;
&lt;br /&gt;
== Action Potential ==&lt;br /&gt;
&lt;br /&gt;
An action potential is the change in electrical potential associated with the passage of an impulse along the membrane of a muscle cell or nerve cell in response to a stimulus, which occurs as the electrical potential briefly (about 1ms) rises and falls (Hodgkin and Huxley).  Specifically, an action potential occurs when the threshold is reached (-65 mV) which activates the voltage-gated ion channels to open.  When the threshold is reached: Na+ channels open and Na+ rushes into the cell while K+ channels open slowly and K+ leaves the cell, the cell then becomes hyperpolarized (Pinel, 2017).  There are three phases of an action potential: the rising phase (Na+ and K+ channels open), repolarization (Na+ channels close), and hyperpolarization (K+ channels start to close).&lt;br /&gt;
&lt;br /&gt;
== Propagated Neural Activity ==&lt;br /&gt;
&lt;br /&gt;
An action potential is generated near the axon hillock when the threshold is reached (-65 mV), the signal is then propagated down (travels) the axon.  Active axonal conduction is due to the diffusion of Na+ into the cell which creates waves of depolarization whereas passive axonal conduction occurs as the signal travels down a myelinated axon along each segment, an action potential is generated at each node of Ranvier between the segments (Pinel, 2017) propagated from one node to the next (saltatory conduction).&lt;br /&gt;
&lt;br /&gt;
Axons that are wrapped in myelin (fatty substance), which serves as insulation of the signal, have faster communication than unmyelinated axons.  The nodes of Ranvier are unmyelinated areas on the axon where the ions flow (e.g., Na+, K+).&lt;br /&gt;
&lt;br /&gt;
== Synaptic Transmission ==&lt;br /&gt;
&lt;br /&gt;
The process by which neurons communicate with each other is synaptic transmission which occurs across synapses using either electrical or chemical signals.  Electrical signaling occurs as an action potential travels from the pre- to the postsynaptic neuron via gap junctions.  However, most synaptic transmission involves chemical signals.  These chemicals are neurotransmitters, molecules which can function either directly (ionotropic) or indirectly via second messengers (metabotropic).  The steps in chemical neurotransmission are: synthesis of the neurotransmitter (in the soma), storage of the neurotransmitter in the vesicles, release into the synapse, binding to the receptor on the postsynaptic neuron, and inactivation of the neurotransmitter via reuptake or enzymatic degradation which terminates the action of the neurotransmitter in the synapse.&lt;br /&gt;
&lt;br /&gt;
== Recording Techniques ==&lt;br /&gt;
=== Electrodes  ===&lt;br /&gt;
&lt;br /&gt;
Electrodes are used to deliver and record electrical stimuli.  In Neurophysiology, electrodes deliver auditory, visual, and electrical stimuli, the amplitude, duration, and rate of which can be varied.  Various types of electrodes are used for recording electrophysiological activity from the scalp, nerves, and muscles (Zouridakis and Papanicoloau, 2000).  There are various types of electrodes such as surface electrodes with hydrogel pads, subdermal needle electrodes, and EEG cups.&lt;br /&gt;
&lt;br /&gt;
=== Amplifiers ===&lt;br /&gt;
&lt;br /&gt;
An amplifier multiplies the input voltage to result in a greater output voltage (amplifier is the circuit and the difference between two input voltages).  Specifically, the amplifier functions as the power and converts alternating current to direct current, thereby flowing in only one direction, a resistor then increases the current flow by reducing the resistance.  The signal dictates the amount of the current, such that a greater signal allows for more current and more current results in more amplitude of the signal.&lt;br /&gt;
&lt;br /&gt;
=== Filtering ===&lt;br /&gt;
&lt;br /&gt;
Filters are used to determine the bandwidth while defining the specific content of the frequencies from the recorded signals, thereby attenuating some frequencies in the signal.  Filters can manipulate latency and amplitude.  There are different types of filters including high pass (attenuate high frequencies) and low pass filters (attenuate low frequencies).  High frequency filters will remove all frequencies above a set value (e.g., 5Hz), similarly, low frequency filters will remove frequencies below a set value (e.g., 5Hz).  Another type of filter is the notch filter which will remove one frequency such as the 60Hz, the background or external frequency that can interfere with the recorded neurophysiological signals as it is the frequency of the alternating current used in the power grid.&lt;br /&gt;
&lt;br /&gt;
=== Signal to Noise Ratio ===&lt;br /&gt;
&lt;br /&gt;
Signal to noise ratio refers to the electrical or neuruphysiological signal and the concurrent interference (noise).  Interference occurs both naturally and artificially.  For example, “noise” from the body (extraneous biological activity) or perisurgical such as the use of instrumentation or electrical interference.  The amplitude of the signal and the amplitude of the noise overlap given that the frequency content of noise contains a myriad of all frequencies and the specific frequency content of the signal would be within that range of all frequencies (Zouridakis and Papanicoloau, 2000).  Therefore, to increase specificity and detection of the electrical signal, the signal to noise ratio, the interference must be dampened which can be accomplished using filters as described above and the signal may be increased using averaging.&lt;br /&gt;
&lt;br /&gt;
=== Signal Averaging ===&lt;br /&gt;
&lt;br /&gt;
Evoked potentials elicited by electrical signals are small and a summation and average are thus necessary for detection of the signal (Zouridakis and Papanicoloau, 2000).  Specifically, the process of averaging is used to record evoked potentials, the electrical response in the brain to repeated sensory stimuli.  Given that the individual electrical responses in response to stimuli are small and therefore difficult to distinguish, and that background signals (e.g., ongoing and simultaneous brain activity, other electrical signals) can interfere with this detection, it is assumed that the signal of interest is embedded within all other ongoing electrical activity (noise), therefore summing and averaging improves (increases) the signal to noise ratio by reducing the noise amplitude when the signal to noise ratio (expressed in decibels) is low; the higher the number of trials that are averaged, the lower the noise.  &lt;br /&gt;
&lt;br /&gt;
The time (ms) just before and after the presentation of the stimulus is known as an epoch.  The averaging procedure involves repeated stimulation and signal recording such that each preceding response is added to the most recent (and at each time point), and those values are then divided.  That is, the epoch of each time point is added to all preceding ones and that sum is divided by the total number of epochs (trials).  For multiple channels recording simultaneously, each channel is averaged independently resulting in a separate evoked potential for each channel.   Evoked responses (e.g., sensory or motor) are averaged responses whereas electrically triggered EMG are nonaveraged.&lt;br /&gt;
&lt;br /&gt;
== Electrical Safety ==&lt;br /&gt;
&lt;br /&gt;
==References==&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=177</id>
		<title>Basic Neurophysiology</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=177"/>
		<updated>2018-04-11T23:12:05Z</updated>

		<summary type="html">&lt;p&gt;Bpw: /* Signal to Noise Ratio */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;br /&gt;
&#039;&#039;&#039;Neurophysiology&#039;&#039;&#039; is the study of the function of the nervous system.&lt;br /&gt;
&lt;br /&gt;
== Membrane Ion Channels ==&lt;br /&gt;
&lt;br /&gt;
All animal cells are enclosed in a plasma membrane, which separates its cytoplasm with the extracellular environment. Cell membrane has the structure of a lipid bilayer, with large molecules embedded in it. Concentration of ions are different across the cell membrane, with more sodium ions (Na+) and chloride ions (Cl-) outside the cell, and more potassium ions (K+) and negative charged protein molecules (A-) inside the cell. Selective ion channels at rest allow potassium ions (K+) cross the membrane easily, creating a voltage more negative inside the cell than outside, which is called resting membrane potential. The resting membrane potential of a neuron is about -70 mV.&lt;br /&gt;
&lt;br /&gt;
== Action Potential ==&lt;br /&gt;
&lt;br /&gt;
An action potential is the change in electrical potential associated with the passage of an impulse along the membrane of a muscle cell or nerve cell in response to a stimulus, which occurs as the electrical potential briefly (about 1ms) rises and falls (Hodgkin and Huxley).  Specifically, an action potential occurs when the threshold is reached (-65 mV) which activates the voltage-gated ion channels to open.  When the threshold is reached: Na+ channels open and Na+ rushes into the cell while K+ channels open slowly and K+ leaves the cell, the cell then becomes hyperpolarized (Pinel, 2017).  There are three phases of an action potential: the rising phase (Na+ and K+ channels open), repolarization (Na+ channels close), and hyperpolarization (K+ channels start to close).&lt;br /&gt;
&lt;br /&gt;
== Propagated Neural Activity ==&lt;br /&gt;
&lt;br /&gt;
An action potential is generated near the axon hillock when the threshold is reached (-65 mV), the signal is then propagated down (travels) the axon.  Active axonal conduction is due to the diffusion of Na+ into the cell which creates waves of depolarization whereas passive axonal conduction occurs as the signal travels down a myelinated axon along each segment, an action potential is generated at each node of Ranvier between the segments (Pinel, 2017) propagated from one node to the next (saltatory conduction).&lt;br /&gt;
&lt;br /&gt;
Axons that are wrapped in myelin (fatty substance), which serves as insulation of the signal, have faster communication than unmyelinated axons.  The nodes of Ranvier are unmyelinated areas on the axon where the ions flow (e.g., Na+, K+).&lt;br /&gt;
&lt;br /&gt;
== Synaptic Transmission ==&lt;br /&gt;
&lt;br /&gt;
The process by which neurons communicate with each other is synaptic transmission which occurs across synapses using either electrical or chemical signals.  Electrical signaling occurs as an action potential travels from the pre- to the postsynaptic neuron via gap junctions.  However, most synaptic transmission involves chemical signals.  These chemicals are neurotransmitters, molecules which can function either directly (ionotropic) or indirectly via second messengers (metabotropic).  The steps in chemical neurotransmission are: synthesis of the neurotransmitter (in the soma), storage of the neurotransmitter in the vesicles, release into the synapse, binding to the receptor on the postsynaptic neuron, and inactivation of the neurotransmitter via reuptake or enzymatic degradation which terminates the action of the neurotransmitter in the synapse.&lt;br /&gt;
&lt;br /&gt;
== Recording Techniques ==&lt;br /&gt;
=== Electrodes  ===&lt;br /&gt;
&lt;br /&gt;
Electrodes are used to deliver and record electrical stimuli.  In Neurophysiology, electrodes deliver auditory, visual, and electrical stimuli, the amplitude, duration, and rate of which can be varied.  Various types of electrodes are used for recording electrophysiological activity from the scalp, nerves, and muscles (Zouridakis and Papanicoloau, 2000).  There are various types of electrodes such as surface electrodes with hydrogel pads, subdermal needle electrodes, and EEG cups.&lt;br /&gt;
&lt;br /&gt;
=== Amplifiers ===&lt;br /&gt;
&lt;br /&gt;
An amplifier multiplies the input voltage to result in a greater output voltage (amplifier is the circuit and the difference between two input voltages).  Specifically, the amplifier functions as the power and converts alternating current to direct current, thereby flowing in only one direction, a resistor then increases the current flow by reducing the resistance.  The signal dictates the amount of the current, such that a greater signal allows for more current and more current results in more amplitude of the signal.&lt;br /&gt;
&lt;br /&gt;
=== Filtering ===&lt;br /&gt;
&lt;br /&gt;
Filters are used to determine the bandwidth while defining the specific content of the frequencies from the recorded signals, thereby attenuating some frequencies in the signal.  Filters can manipulate latency and amplitude.  There are different types of filters including high pass (attenuate high frequencies) and low pass filters (attenuate low frequencies).  High frequency filters will remove all frequencies above a set value (e.g., 5Hz), similarly, low frequency filters will remove frequencies below a set value (e.g., 5Hz).  Another type of filter is the notch filter which will remove one frequency such as the 60Hz, the background or external frequency that can interfere with the recorded neurophysiological signals as it is the frequency of the alternating current used in the power grid.&lt;br /&gt;
&lt;br /&gt;
=== Signal to Noise Ratio ===&lt;br /&gt;
&lt;br /&gt;
Signal to noise ratio refers to the electrical or neuruphysiological signal and the concurrent interference (noise).  Interference occurs both naturally and artificially.  For example, “noise” from the body (extraneous biological activity) or perisurgical such as the use of instrumentation or electrical interference.  The amplitude of the signal and the amplitude of the noise overlap given that the frequency content of noise contains a myriad of all frequencies and the specific frequency content of the signal would be within that range of all frequencies (Zouridakis and Papanicoloau, 2000).  Therefore, to increase specificity and detection of the electrical signal, the signal to noise ratio, the interference must be dampened which can be accomplished using filters as described above and the signal may be increased using averaging.&lt;br /&gt;
&lt;br /&gt;
=== Signal Averaging ===&lt;br /&gt;
&lt;br /&gt;
== Electrical Safety ==&lt;br /&gt;
&lt;br /&gt;
==References==&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=176</id>
		<title>Basic Neurophysiology</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=176"/>
		<updated>2018-04-11T23:11:47Z</updated>

		<summary type="html">&lt;p&gt;Bpw: /* Filtering */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;br /&gt;
&#039;&#039;&#039;Neurophysiology&#039;&#039;&#039; is the study of the function of the nervous system.&lt;br /&gt;
&lt;br /&gt;
== Membrane Ion Channels ==&lt;br /&gt;
&lt;br /&gt;
All animal cells are enclosed in a plasma membrane, which separates its cytoplasm with the extracellular environment. Cell membrane has the structure of a lipid bilayer, with large molecules embedded in it. Concentration of ions are different across the cell membrane, with more sodium ions (Na+) and chloride ions (Cl-) outside the cell, and more potassium ions (K+) and negative charged protein molecules (A-) inside the cell. Selective ion channels at rest allow potassium ions (K+) cross the membrane easily, creating a voltage more negative inside the cell than outside, which is called resting membrane potential. The resting membrane potential of a neuron is about -70 mV.&lt;br /&gt;
&lt;br /&gt;
== Action Potential ==&lt;br /&gt;
&lt;br /&gt;
An action potential is the change in electrical potential associated with the passage of an impulse along the membrane of a muscle cell or nerve cell in response to a stimulus, which occurs as the electrical potential briefly (about 1ms) rises and falls (Hodgkin and Huxley).  Specifically, an action potential occurs when the threshold is reached (-65 mV) which activates the voltage-gated ion channels to open.  When the threshold is reached: Na+ channels open and Na+ rushes into the cell while K+ channels open slowly and K+ leaves the cell, the cell then becomes hyperpolarized (Pinel, 2017).  There are three phases of an action potential: the rising phase (Na+ and K+ channels open), repolarization (Na+ channels close), and hyperpolarization (K+ channels start to close).&lt;br /&gt;
&lt;br /&gt;
== Propagated Neural Activity ==&lt;br /&gt;
&lt;br /&gt;
An action potential is generated near the axon hillock when the threshold is reached (-65 mV), the signal is then propagated down (travels) the axon.  Active axonal conduction is due to the diffusion of Na+ into the cell which creates waves of depolarization whereas passive axonal conduction occurs as the signal travels down a myelinated axon along each segment, an action potential is generated at each node of Ranvier between the segments (Pinel, 2017) propagated from one node to the next (saltatory conduction).&lt;br /&gt;
&lt;br /&gt;
Axons that are wrapped in myelin (fatty substance), which serves as insulation of the signal, have faster communication than unmyelinated axons.  The nodes of Ranvier are unmyelinated areas on the axon where the ions flow (e.g., Na+, K+).&lt;br /&gt;
&lt;br /&gt;
== Synaptic Transmission ==&lt;br /&gt;
&lt;br /&gt;
The process by which neurons communicate with each other is synaptic transmission which occurs across synapses using either electrical or chemical signals.  Electrical signaling occurs as an action potential travels from the pre- to the postsynaptic neuron via gap junctions.  However, most synaptic transmission involves chemical signals.  These chemicals are neurotransmitters, molecules which can function either directly (ionotropic) or indirectly via second messengers (metabotropic).  The steps in chemical neurotransmission are: synthesis of the neurotransmitter (in the soma), storage of the neurotransmitter in the vesicles, release into the synapse, binding to the receptor on the postsynaptic neuron, and inactivation of the neurotransmitter via reuptake or enzymatic degradation which terminates the action of the neurotransmitter in the synapse.&lt;br /&gt;
&lt;br /&gt;
== Recording Techniques ==&lt;br /&gt;
=== Electrodes  ===&lt;br /&gt;
&lt;br /&gt;
Electrodes are used to deliver and record electrical stimuli.  In Neurophysiology, electrodes deliver auditory, visual, and electrical stimuli, the amplitude, duration, and rate of which can be varied.  Various types of electrodes are used for recording electrophysiological activity from the scalp, nerves, and muscles (Zouridakis and Papanicoloau, 2000).  There are various types of electrodes such as surface electrodes with hydrogel pads, subdermal needle electrodes, and EEG cups.&lt;br /&gt;
&lt;br /&gt;
=== Amplifiers ===&lt;br /&gt;
&lt;br /&gt;
An amplifier multiplies the input voltage to result in a greater output voltage (amplifier is the circuit and the difference between two input voltages).  Specifically, the amplifier functions as the power and converts alternating current to direct current, thereby flowing in only one direction, a resistor then increases the current flow by reducing the resistance.  The signal dictates the amount of the current, such that a greater signal allows for more current and more current results in more amplitude of the signal.&lt;br /&gt;
&lt;br /&gt;
=== Filtering ===&lt;br /&gt;
&lt;br /&gt;
Filters are used to determine the bandwidth while defining the specific content of the frequencies from the recorded signals, thereby attenuating some frequencies in the signal.  Filters can manipulate latency and amplitude.  There are different types of filters including high pass (attenuate high frequencies) and low pass filters (attenuate low frequencies).  High frequency filters will remove all frequencies above a set value (e.g., 5Hz), similarly, low frequency filters will remove frequencies below a set value (e.g., 5Hz).  Another type of filter is the notch filter which will remove one frequency such as the 60Hz, the background or external frequency that can interfere with the recorded neurophysiological signals as it is the frequency of the alternating current used in the power grid.&lt;br /&gt;
&lt;br /&gt;
=== Signal to Noise Ratio ===&lt;br /&gt;
=== Signal Averaging ===&lt;br /&gt;
&lt;br /&gt;
== Electrical Safety ==&lt;br /&gt;
&lt;br /&gt;
==References==&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=175</id>
		<title>Basic Neurophysiology</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=175"/>
		<updated>2018-04-11T23:11:31Z</updated>

		<summary type="html">&lt;p&gt;Bpw: /* Amplifiers */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;br /&gt;
&#039;&#039;&#039;Neurophysiology&#039;&#039;&#039; is the study of the function of the nervous system.&lt;br /&gt;
&lt;br /&gt;
== Membrane Ion Channels ==&lt;br /&gt;
&lt;br /&gt;
All animal cells are enclosed in a plasma membrane, which separates its cytoplasm with the extracellular environment. Cell membrane has the structure of a lipid bilayer, with large molecules embedded in it. Concentration of ions are different across the cell membrane, with more sodium ions (Na+) and chloride ions (Cl-) outside the cell, and more potassium ions (K+) and negative charged protein molecules (A-) inside the cell. Selective ion channels at rest allow potassium ions (K+) cross the membrane easily, creating a voltage more negative inside the cell than outside, which is called resting membrane potential. The resting membrane potential of a neuron is about -70 mV.&lt;br /&gt;
&lt;br /&gt;
== Action Potential ==&lt;br /&gt;
&lt;br /&gt;
An action potential is the change in electrical potential associated with the passage of an impulse along the membrane of a muscle cell or nerve cell in response to a stimulus, which occurs as the electrical potential briefly (about 1ms) rises and falls (Hodgkin and Huxley).  Specifically, an action potential occurs when the threshold is reached (-65 mV) which activates the voltage-gated ion channels to open.  When the threshold is reached: Na+ channels open and Na+ rushes into the cell while K+ channels open slowly and K+ leaves the cell, the cell then becomes hyperpolarized (Pinel, 2017).  There are three phases of an action potential: the rising phase (Na+ and K+ channels open), repolarization (Na+ channels close), and hyperpolarization (K+ channels start to close).&lt;br /&gt;
&lt;br /&gt;
== Propagated Neural Activity ==&lt;br /&gt;
&lt;br /&gt;
An action potential is generated near the axon hillock when the threshold is reached (-65 mV), the signal is then propagated down (travels) the axon.  Active axonal conduction is due to the diffusion of Na+ into the cell which creates waves of depolarization whereas passive axonal conduction occurs as the signal travels down a myelinated axon along each segment, an action potential is generated at each node of Ranvier between the segments (Pinel, 2017) propagated from one node to the next (saltatory conduction).&lt;br /&gt;
&lt;br /&gt;
Axons that are wrapped in myelin (fatty substance), which serves as insulation of the signal, have faster communication than unmyelinated axons.  The nodes of Ranvier are unmyelinated areas on the axon where the ions flow (e.g., Na+, K+).&lt;br /&gt;
&lt;br /&gt;
== Synaptic Transmission ==&lt;br /&gt;
&lt;br /&gt;
The process by which neurons communicate with each other is synaptic transmission which occurs across synapses using either electrical or chemical signals.  Electrical signaling occurs as an action potential travels from the pre- to the postsynaptic neuron via gap junctions.  However, most synaptic transmission involves chemical signals.  These chemicals are neurotransmitters, molecules which can function either directly (ionotropic) or indirectly via second messengers (metabotropic).  The steps in chemical neurotransmission are: synthesis of the neurotransmitter (in the soma), storage of the neurotransmitter in the vesicles, release into the synapse, binding to the receptor on the postsynaptic neuron, and inactivation of the neurotransmitter via reuptake or enzymatic degradation which terminates the action of the neurotransmitter in the synapse.&lt;br /&gt;
&lt;br /&gt;
== Recording Techniques ==&lt;br /&gt;
=== Electrodes  ===&lt;br /&gt;
&lt;br /&gt;
Electrodes are used to deliver and record electrical stimuli.  In Neurophysiology, electrodes deliver auditory, visual, and electrical stimuli, the amplitude, duration, and rate of which can be varied.  Various types of electrodes are used for recording electrophysiological activity from the scalp, nerves, and muscles (Zouridakis and Papanicoloau, 2000).  There are various types of electrodes such as surface electrodes with hydrogel pads, subdermal needle electrodes, and EEG cups.&lt;br /&gt;
&lt;br /&gt;
=== Amplifiers ===&lt;br /&gt;
&lt;br /&gt;
An amplifier multiplies the input voltage to result in a greater output voltage (amplifier is the circuit and the difference between two input voltages).  Specifically, the amplifier functions as the power and converts alternating current to direct current, thereby flowing in only one direction, a resistor then increases the current flow by reducing the resistance.  The signal dictates the amount of the current, such that a greater signal allows for more current and more current results in more amplitude of the signal.&lt;br /&gt;
&lt;br /&gt;
=== Filtering ===&lt;br /&gt;
=== Signal to Noise Ratio ===&lt;br /&gt;
=== Signal Averaging ===&lt;br /&gt;
&lt;br /&gt;
== Electrical Safety ==&lt;br /&gt;
&lt;br /&gt;
==References==&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=174</id>
		<title>Basic Neurophysiology</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=174"/>
		<updated>2018-04-11T23:11:15Z</updated>

		<summary type="html">&lt;p&gt;Bpw: /* Electrodes */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;br /&gt;
&#039;&#039;&#039;Neurophysiology&#039;&#039;&#039; is the study of the function of the nervous system.&lt;br /&gt;
&lt;br /&gt;
== Membrane Ion Channels ==&lt;br /&gt;
&lt;br /&gt;
All animal cells are enclosed in a plasma membrane, which separates its cytoplasm with the extracellular environment. Cell membrane has the structure of a lipid bilayer, with large molecules embedded in it. Concentration of ions are different across the cell membrane, with more sodium ions (Na+) and chloride ions (Cl-) outside the cell, and more potassium ions (K+) and negative charged protein molecules (A-) inside the cell. Selective ion channels at rest allow potassium ions (K+) cross the membrane easily, creating a voltage more negative inside the cell than outside, which is called resting membrane potential. The resting membrane potential of a neuron is about -70 mV.&lt;br /&gt;
&lt;br /&gt;
== Action Potential ==&lt;br /&gt;
&lt;br /&gt;
An action potential is the change in electrical potential associated with the passage of an impulse along the membrane of a muscle cell or nerve cell in response to a stimulus, which occurs as the electrical potential briefly (about 1ms) rises and falls (Hodgkin and Huxley).  Specifically, an action potential occurs when the threshold is reached (-65 mV) which activates the voltage-gated ion channels to open.  When the threshold is reached: Na+ channels open and Na+ rushes into the cell while K+ channels open slowly and K+ leaves the cell, the cell then becomes hyperpolarized (Pinel, 2017).  There are three phases of an action potential: the rising phase (Na+ and K+ channels open), repolarization (Na+ channels close), and hyperpolarization (K+ channels start to close).&lt;br /&gt;
&lt;br /&gt;
== Propagated Neural Activity ==&lt;br /&gt;
&lt;br /&gt;
An action potential is generated near the axon hillock when the threshold is reached (-65 mV), the signal is then propagated down (travels) the axon.  Active axonal conduction is due to the diffusion of Na+ into the cell which creates waves of depolarization whereas passive axonal conduction occurs as the signal travels down a myelinated axon along each segment, an action potential is generated at each node of Ranvier between the segments (Pinel, 2017) propagated from one node to the next (saltatory conduction).&lt;br /&gt;
&lt;br /&gt;
Axons that are wrapped in myelin (fatty substance), which serves as insulation of the signal, have faster communication than unmyelinated axons.  The nodes of Ranvier are unmyelinated areas on the axon where the ions flow (e.g., Na+, K+).&lt;br /&gt;
&lt;br /&gt;
== Synaptic Transmission ==&lt;br /&gt;
&lt;br /&gt;
The process by which neurons communicate with each other is synaptic transmission which occurs across synapses using either electrical or chemical signals.  Electrical signaling occurs as an action potential travels from the pre- to the postsynaptic neuron via gap junctions.  However, most synaptic transmission involves chemical signals.  These chemicals are neurotransmitters, molecules which can function either directly (ionotropic) or indirectly via second messengers (metabotropic).  The steps in chemical neurotransmission are: synthesis of the neurotransmitter (in the soma), storage of the neurotransmitter in the vesicles, release into the synapse, binding to the receptor on the postsynaptic neuron, and inactivation of the neurotransmitter via reuptake or enzymatic degradation which terminates the action of the neurotransmitter in the synapse.&lt;br /&gt;
&lt;br /&gt;
== Recording Techniques ==&lt;br /&gt;
=== Electrodes  ===&lt;br /&gt;
&lt;br /&gt;
Electrodes are used to deliver and record electrical stimuli.  In Neurophysiology, electrodes deliver auditory, visual, and electrical stimuli, the amplitude, duration, and rate of which can be varied.  Various types of electrodes are used for recording electrophysiological activity from the scalp, nerves, and muscles (Zouridakis and Papanicoloau, 2000).  There are various types of electrodes such as surface electrodes with hydrogel pads, subdermal needle electrodes, and EEG cups.&lt;br /&gt;
&lt;br /&gt;
=== Amplifiers ===&lt;br /&gt;
=== Filtering ===&lt;br /&gt;
=== Signal to Noise Ratio ===&lt;br /&gt;
=== Signal Averaging ===&lt;br /&gt;
&lt;br /&gt;
== Electrical Safety ==&lt;br /&gt;
&lt;br /&gt;
==References==&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=173</id>
		<title>Basic Neurophysiology</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=173"/>
		<updated>2018-04-11T23:10:53Z</updated>

		<summary type="html">&lt;p&gt;Bpw: /* Synaptic Transmission */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;br /&gt;
&#039;&#039;&#039;Neurophysiology&#039;&#039;&#039; is the study of the function of the nervous system.&lt;br /&gt;
&lt;br /&gt;
== Membrane Ion Channels ==&lt;br /&gt;
&lt;br /&gt;
All animal cells are enclosed in a plasma membrane, which separates its cytoplasm with the extracellular environment. Cell membrane has the structure of a lipid bilayer, with large molecules embedded in it. Concentration of ions are different across the cell membrane, with more sodium ions (Na+) and chloride ions (Cl-) outside the cell, and more potassium ions (K+) and negative charged protein molecules (A-) inside the cell. Selective ion channels at rest allow potassium ions (K+) cross the membrane easily, creating a voltage more negative inside the cell than outside, which is called resting membrane potential. The resting membrane potential of a neuron is about -70 mV.&lt;br /&gt;
&lt;br /&gt;
== Action Potential ==&lt;br /&gt;
&lt;br /&gt;
An action potential is the change in electrical potential associated with the passage of an impulse along the membrane of a muscle cell or nerve cell in response to a stimulus, which occurs as the electrical potential briefly (about 1ms) rises and falls (Hodgkin and Huxley).  Specifically, an action potential occurs when the threshold is reached (-65 mV) which activates the voltage-gated ion channels to open.  When the threshold is reached: Na+ channels open and Na+ rushes into the cell while K+ channels open slowly and K+ leaves the cell, the cell then becomes hyperpolarized (Pinel, 2017).  There are three phases of an action potential: the rising phase (Na+ and K+ channels open), repolarization (Na+ channels close), and hyperpolarization (K+ channels start to close).&lt;br /&gt;
&lt;br /&gt;
== Propagated Neural Activity ==&lt;br /&gt;
&lt;br /&gt;
An action potential is generated near the axon hillock when the threshold is reached (-65 mV), the signal is then propagated down (travels) the axon.  Active axonal conduction is due to the diffusion of Na+ into the cell which creates waves of depolarization whereas passive axonal conduction occurs as the signal travels down a myelinated axon along each segment, an action potential is generated at each node of Ranvier between the segments (Pinel, 2017) propagated from one node to the next (saltatory conduction).&lt;br /&gt;
&lt;br /&gt;
Axons that are wrapped in myelin (fatty substance), which serves as insulation of the signal, have faster communication than unmyelinated axons.  The nodes of Ranvier are unmyelinated areas on the axon where the ions flow (e.g., Na+, K+).&lt;br /&gt;
&lt;br /&gt;
== Synaptic Transmission ==&lt;br /&gt;
&lt;br /&gt;
The process by which neurons communicate with each other is synaptic transmission which occurs across synapses using either electrical or chemical signals.  Electrical signaling occurs as an action potential travels from the pre- to the postsynaptic neuron via gap junctions.  However, most synaptic transmission involves chemical signals.  These chemicals are neurotransmitters, molecules which can function either directly (ionotropic) or indirectly via second messengers (metabotropic).  The steps in chemical neurotransmission are: synthesis of the neurotransmitter (in the soma), storage of the neurotransmitter in the vesicles, release into the synapse, binding to the receptor on the postsynaptic neuron, and inactivation of the neurotransmitter via reuptake or enzymatic degradation which terminates the action of the neurotransmitter in the synapse.&lt;br /&gt;
&lt;br /&gt;
== Recording Techniques ==&lt;br /&gt;
=== Electrodes  ===&lt;br /&gt;
=== Amplifiers ===&lt;br /&gt;
=== Filtering ===&lt;br /&gt;
=== Signal to Noise Ratio ===&lt;br /&gt;
=== Signal Averaging ===&lt;br /&gt;
&lt;br /&gt;
== Electrical Safety ==&lt;br /&gt;
&lt;br /&gt;
==References==&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=172</id>
		<title>Basic Neurophysiology</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=172"/>
		<updated>2018-04-11T23:10:31Z</updated>

		<summary type="html">&lt;p&gt;Bpw: /* Propagated Neural Activity */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;br /&gt;
&#039;&#039;&#039;Neurophysiology&#039;&#039;&#039; is the study of the function of the nervous system.&lt;br /&gt;
&lt;br /&gt;
== Membrane Ion Channels ==&lt;br /&gt;
&lt;br /&gt;
All animal cells are enclosed in a plasma membrane, which separates its cytoplasm with the extracellular environment. Cell membrane has the structure of a lipid bilayer, with large molecules embedded in it. Concentration of ions are different across the cell membrane, with more sodium ions (Na+) and chloride ions (Cl-) outside the cell, and more potassium ions (K+) and negative charged protein molecules (A-) inside the cell. Selective ion channels at rest allow potassium ions (K+) cross the membrane easily, creating a voltage more negative inside the cell than outside, which is called resting membrane potential. The resting membrane potential of a neuron is about -70 mV.&lt;br /&gt;
&lt;br /&gt;
== Action Potential ==&lt;br /&gt;
&lt;br /&gt;
An action potential is the change in electrical potential associated with the passage of an impulse along the membrane of a muscle cell or nerve cell in response to a stimulus, which occurs as the electrical potential briefly (about 1ms) rises and falls (Hodgkin and Huxley).  Specifically, an action potential occurs when the threshold is reached (-65 mV) which activates the voltage-gated ion channels to open.  When the threshold is reached: Na+ channels open and Na+ rushes into the cell while K+ channels open slowly and K+ leaves the cell, the cell then becomes hyperpolarized (Pinel, 2017).  There are three phases of an action potential: the rising phase (Na+ and K+ channels open), repolarization (Na+ channels close), and hyperpolarization (K+ channels start to close).&lt;br /&gt;
&lt;br /&gt;
== Propagated Neural Activity ==&lt;br /&gt;
&lt;br /&gt;
An action potential is generated near the axon hillock when the threshold is reached (-65 mV), the signal is then propagated down (travels) the axon.  Active axonal conduction is due to the diffusion of Na+ into the cell which creates waves of depolarization whereas passive axonal conduction occurs as the signal travels down a myelinated axon along each segment, an action potential is generated at each node of Ranvier between the segments (Pinel, 2017) propagated from one node to the next (saltatory conduction).&lt;br /&gt;
&lt;br /&gt;
Axons that are wrapped in myelin (fatty substance), which serves as insulation of the signal, have faster communication than unmyelinated axons.  The nodes of Ranvier are unmyelinated areas on the axon where the ions flow (e.g., Na+, K+).&lt;br /&gt;
&lt;br /&gt;
== Synaptic Transmission ==&lt;br /&gt;
&lt;br /&gt;
== Recording Techniques ==&lt;br /&gt;
=== Electrodes  ===&lt;br /&gt;
=== Amplifiers ===&lt;br /&gt;
=== Filtering ===&lt;br /&gt;
=== Signal to Noise Ratio ===&lt;br /&gt;
=== Signal Averaging ===&lt;br /&gt;
&lt;br /&gt;
== Electrical Safety ==&lt;br /&gt;
&lt;br /&gt;
==References==&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=171</id>
		<title>Basic Neurophysiology</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=171"/>
		<updated>2018-04-11T23:10:10Z</updated>

		<summary type="html">&lt;p&gt;Bpw: /* Propagated Neural Activity */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;br /&gt;
&#039;&#039;&#039;Neurophysiology&#039;&#039;&#039; is the study of the function of the nervous system.&lt;br /&gt;
&lt;br /&gt;
== Membrane Ion Channels ==&lt;br /&gt;
&lt;br /&gt;
All animal cells are enclosed in a plasma membrane, which separates its cytoplasm with the extracellular environment. Cell membrane has the structure of a lipid bilayer, with large molecules embedded in it. Concentration of ions are different across the cell membrane, with more sodium ions (Na+) and chloride ions (Cl-) outside the cell, and more potassium ions (K+) and negative charged protein molecules (A-) inside the cell. Selective ion channels at rest allow potassium ions (K+) cross the membrane easily, creating a voltage more negative inside the cell than outside, which is called resting membrane potential. The resting membrane potential of a neuron is about -70 mV.&lt;br /&gt;
&lt;br /&gt;
== Action Potential ==&lt;br /&gt;
&lt;br /&gt;
An action potential is the change in electrical potential associated with the passage of an impulse along the membrane of a muscle cell or nerve cell in response to a stimulus, which occurs as the electrical potential briefly (about 1ms) rises and falls (Hodgkin and Huxley).  Specifically, an action potential occurs when the threshold is reached (-65 mV) which activates the voltage-gated ion channels to open.  When the threshold is reached: Na+ channels open and Na+ rushes into the cell while K+ channels open slowly and K+ leaves the cell, the cell then becomes hyperpolarized (Pinel, 2017).  There are three phases of an action potential: the rising phase (Na+ and K+ channels open), repolarization (Na+ channels close), and hyperpolarization (K+ channels start to close).&lt;br /&gt;
&lt;br /&gt;
== Propagated Neural Activity ==&lt;br /&gt;
&lt;br /&gt;
An action potential is generated near the axon hillock when the threshold is reached (-65 mV), the signal is then propagated down (travels) the axon.  Active axonal conduction is due to the diffusion of Na+ into the cell which creates waves of depolarization whereas passive axonal conduction occurs as the signal travels down a myelinated axon along each segment, an action potential is generated at each node of Ranvier between the segments (Pinel, 2017) propagated from one node to the next (saltatory conduction).&lt;br /&gt;
&lt;br /&gt;
== Synaptic Transmission ==&lt;br /&gt;
&lt;br /&gt;
== Recording Techniques ==&lt;br /&gt;
=== Electrodes  ===&lt;br /&gt;
=== Amplifiers ===&lt;br /&gt;
=== Filtering ===&lt;br /&gt;
=== Signal to Noise Ratio ===&lt;br /&gt;
=== Signal Averaging ===&lt;br /&gt;
&lt;br /&gt;
== Electrical Safety ==&lt;br /&gt;
&lt;br /&gt;
==References==&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=170</id>
		<title>Basic Neurophysiology</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=170"/>
		<updated>2018-04-11T23:09:35Z</updated>

		<summary type="html">&lt;p&gt;Bpw: /* Membrane Ion Channels */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;br /&gt;
&#039;&#039;&#039;Neurophysiology&#039;&#039;&#039; is the study of the function of the nervous system.&lt;br /&gt;
&lt;br /&gt;
== Membrane Ion Channels ==&lt;br /&gt;
&lt;br /&gt;
All animal cells are enclosed in a plasma membrane, which separates its cytoplasm with the extracellular environment. Cell membrane has the structure of a lipid bilayer, with large molecules embedded in it. Concentration of ions are different across the cell membrane, with more sodium ions (Na+) and chloride ions (Cl-) outside the cell, and more potassium ions (K+) and negative charged protein molecules (A-) inside the cell. Selective ion channels at rest allow potassium ions (K+) cross the membrane easily, creating a voltage more negative inside the cell than outside, which is called resting membrane potential. The resting membrane potential of a neuron is about -70 mV.&lt;br /&gt;
&lt;br /&gt;
== Action Potential ==&lt;br /&gt;
&lt;br /&gt;
An action potential is the change in electrical potential associated with the passage of an impulse along the membrane of a muscle cell or nerve cell in response to a stimulus, which occurs as the electrical potential briefly (about 1ms) rises and falls (Hodgkin and Huxley).  Specifically, an action potential occurs when the threshold is reached (-65 mV) which activates the voltage-gated ion channels to open.  When the threshold is reached: Na+ channels open and Na+ rushes into the cell while K+ channels open slowly and K+ leaves the cell, the cell then becomes hyperpolarized (Pinel, 2017).  There are three phases of an action potential: the rising phase (Na+ and K+ channels open), repolarization (Na+ channels close), and hyperpolarization (K+ channels start to close).&lt;br /&gt;
&lt;br /&gt;
== Propagated Neural Activity ==&lt;br /&gt;
&lt;br /&gt;
== Synaptic Transmission ==&lt;br /&gt;
&lt;br /&gt;
== Recording Techniques ==&lt;br /&gt;
=== Electrodes  ===&lt;br /&gt;
=== Amplifiers ===&lt;br /&gt;
=== Filtering ===&lt;br /&gt;
=== Signal to Noise Ratio ===&lt;br /&gt;
=== Signal Averaging ===&lt;br /&gt;
&lt;br /&gt;
== Electrical Safety ==&lt;br /&gt;
&lt;br /&gt;
==References==&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=169</id>
		<title>Basic Neurophysiology</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=169"/>
		<updated>2018-04-11T23:08:49Z</updated>

		<summary type="html">&lt;p&gt;Bpw: /* Action Potential */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;br /&gt;
&#039;&#039;&#039;Neurophysiology&#039;&#039;&#039; is the study of the function of the nervous system.&lt;br /&gt;
&lt;br /&gt;
== Membrane Ion Channels ==&lt;br /&gt;
&lt;br /&gt;
All animal cells are enclosed in a plasma membrane, which separates its cytoplasm with the extracellular environment. Cell membrane has the structure of a lipid bilayer, with large molecules embedded in it. Concentration of ions are different across the cell membrane, with more sodium ions (Na+) and chloride ions (Cl-) outside the cell, and more potassium ions (K+) and negative charged protein molecules (A-) inside the cell. Selective ion channels at rest allow potassium ions (K+) cross the membrane easily, creating a voltage more negative inside the cell than outside, which is called resting membrane potential. The resting membrane potential of a neuron is about -70 mV.&lt;br /&gt;
&lt;br /&gt;
== Action Potential ==An action potential is the change in electrical potential associated with the passage of an impulse along the membrane of a muscle cell or nerve cell in response to a stimulus, which occurs as the electrical potential briefly (about 1ms) rises and falls (Hodgkin and Huxley).  Specifically, an action potential occurs when the threshold is reached (-65 mV) which activates the voltage-gated ion channels to open.  When the threshold is reached: Na+ channels open and Na+ rushes into the cell while K+ channels open slowly and K+ leaves the cell, the cell then becomes hyperpolarized (Pinel, 2017).  There are three phases of an action potential: the rising phase (Na+ and K+ channels open), repolarization (Na+ channels close), and hyperpolarization (K+ channels start to close).&lt;br /&gt;
&lt;br /&gt;
== Propagated Neural Activity ==&lt;br /&gt;
&lt;br /&gt;
== Synaptic Transmission ==&lt;br /&gt;
&lt;br /&gt;
== Recording Techniques ==&lt;br /&gt;
=== Electrodes  ===&lt;br /&gt;
=== Amplifiers ===&lt;br /&gt;
=== Filtering ===&lt;br /&gt;
=== Signal to Noise Ratio ===&lt;br /&gt;
=== Signal Averaging ===&lt;br /&gt;
&lt;br /&gt;
== Electrical Safety ==&lt;br /&gt;
&lt;br /&gt;
==References==&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=168</id>
		<title>Basic Neurophysiology</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=168"/>
		<updated>2014-06-25T19:44:22Z</updated>

		<summary type="html">&lt;p&gt;Bpw: /* Membrane Ion Channels */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;br /&gt;
&#039;&#039;&#039;Neurophysiology&#039;&#039;&#039; is the study of the function of the nervous system.&lt;br /&gt;
&lt;br /&gt;
== Membrane Ion Channels ==&lt;br /&gt;
&lt;br /&gt;
All animal cells are enclosed in a plasma membrane, which separates its cytoplasm with the extracellular environment. Cell membrane has the structure of a lipid bilayer, with large molecules embedded in it. Concentration of ions are different across the cell membrane, with more sodium ions (Na+) and chloride ions (Cl-) outside the cell, and more potassium ions (K+) and negative charged protein molecules (A-) inside the cell. Selective ion channels at rest allow potassium ions (K+) cross the membrane easily, creating a voltage more negative inside the cell than outside, which is called resting membrane potential. The resting membrane potential of a neuron is about -70 mV.&lt;br /&gt;
&lt;br /&gt;
== Action Potential ==&lt;br /&gt;
&lt;br /&gt;
== Propagated Neural Activity ==&lt;br /&gt;
&lt;br /&gt;
== Synaptic Transmission ==&lt;br /&gt;
&lt;br /&gt;
== Recording Techniques ==&lt;br /&gt;
=== Electrodes  ===&lt;br /&gt;
=== Amplifiers ===&lt;br /&gt;
=== Filtering ===&lt;br /&gt;
=== Signal to Noise Ratio ===&lt;br /&gt;
=== Signal Averaging ===&lt;br /&gt;
&lt;br /&gt;
== Electrical Safety ==&lt;br /&gt;
&lt;br /&gt;
==References==&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=167</id>
		<title>Basic Neurophysiology</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=Basic_Neurophysiology&amp;diff=167"/>
		<updated>2014-06-23T21:16:19Z</updated>

		<summary type="html">&lt;p&gt;Bpw: /* Membrane Ion Channels */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;br /&gt;
&#039;&#039;&#039;Neurophysiology&#039;&#039;&#039; is the study of the function of the nervous system.&lt;br /&gt;
&lt;br /&gt;
== Membrane Ion Channels ==&lt;br /&gt;
&lt;br /&gt;
All animal cells are enclosed in a plasma membrane, which separates its cytoplasm with the extracellular environment. Cell membrane has the structure of a lipid bilayer, with large molecules embedded in it. Concentration of ions are different across the cell membrane, with more sodium ions (Na+) and chloride ions (Cl-) outside the cell, and more potassium ions (K+) and negative charged protein molecules (A-) inside the cell.&lt;br /&gt;
&lt;br /&gt;
== Action Potential ==&lt;br /&gt;
&lt;br /&gt;
== Propagated Neural Activity ==&lt;br /&gt;
&lt;br /&gt;
== Synaptic Transmission ==&lt;br /&gt;
&lt;br /&gt;
== Recording Techniques ==&lt;br /&gt;
=== Electrodes  ===&lt;br /&gt;
=== Amplifiers ===&lt;br /&gt;
=== Filtering ===&lt;br /&gt;
=== Signal to Noise Ratio ===&lt;br /&gt;
=== Signal Averaging ===&lt;br /&gt;
&lt;br /&gt;
== Electrical Safety ==&lt;br /&gt;
&lt;br /&gt;
==References==&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=General_Information&amp;diff=166</id>
		<title>General Information</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=General_Information&amp;diff=166"/>
		<updated>2014-06-23T20:03:49Z</updated>

		<summary type="html">&lt;p&gt;Bpw: /* Jobs */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Introduction==&lt;br /&gt;
&lt;br /&gt;
==Organizations==&lt;br /&gt;
&lt;br /&gt;
#[http://www.asnm.org American Society of Neurophysiological Monitoring]&lt;br /&gt;
#[http://www.acns.org American Clinical Neurophysiology Society]&lt;br /&gt;
#[http://www.aset.org The Neurodiagnostic Society (ASET)]&lt;br /&gt;
#[http://abnm.info American Board of Neurophysiologic Monitoring]&lt;br /&gt;
#[http://www.neurophysiology.org International Society of Intraoperative Neurophysiology (ISIN)]&lt;br /&gt;
#[http://www.ifcn.info International Federation of Clinical Neurophysiology]&lt;br /&gt;
#[http://www.aan.com  American Academy of Neurology]&lt;br /&gt;
#[http://www.oegkn.at/translat.htm Austrian Society for Clinical Neurophysiology]&lt;br /&gt;
#[http://www.neurofisiologia.net Italian Neurophysiological Technologists]&lt;br /&gt;
#[http://www.smnfc.com  Mexican Clinical Neurophysiology Society] Represents all certified clinical neurophysiologists in Mexico, with local and global event information in Spanish.&lt;br /&gt;
&lt;br /&gt;
==Conferences==&lt;br /&gt;
&lt;br /&gt;
#[http://asnm.site-ym.com/events/event_details.asp?id=326009 ASNM 2014 Annual Meeting] May 1-4, 2014, Fairmont Chicago Millennium Park, Chicago, Illinois&lt;br /&gt;
#[http://www.acns.org/meetings/annual-meeting-and-courses/2014/program American Clinical Neurophysiology Society Annual Meeting &amp;amp; Courses] February 4-9, 2014, Atlanta, Georgia.&lt;br /&gt;
#[http://www.isincapetown2013.com 4th International Conference on Intraoperative Neurophysiology] November 14-16, 2013, Cape Town, South Africa.&lt;br /&gt;
#[https://asnm.site-ym.com/?page=2013Annual ASNM 2013 Annual Meeting] Procedure Based IONM &amp;amp; State-Of-The-Art Scientific Discussion, May 2-5, 2013, Boston, Massachusetts.&lt;br /&gt;
&lt;br /&gt;
==Books==&lt;br /&gt;
#[http://www.amazon.com/Intraoperative-Neurophysiology-Mirela-Simon-MD-ebook/dp/B004MME2HY/tag=clinicalneurophy Intraoperative Neurophysiology] by Mirela Simon&lt;br /&gt;
#[http://www.amazon.com/Neurophysiology-Neurosurgery-Modern-Intraoperative-Approach/dp/0122090365/tag=clinicalneurophy Neurophysiology in Neurosurgery: A Modern Intraoperative Approach] by  Vedran Deletis and Jay Shils&lt;br /&gt;
#[http://www.amazon.com/Intraoperative-Neurophysiological-Monitoring-Aage-Møller/dp/1588297039/tag=clinicalneurophy Intraoperative Neurophysiological Monitoring] by Aage R. Møller&lt;br /&gt;
#[http://www.amazon.com/Intraoperative-Monitoring-Neural-Function-Neurophysiology/dp/044451824X/tag=clinicalneurophy Intraoperative Monitoring of Neural Function: Handbook of Clinical Neurophysiology] by  Marc R. Nuwer&lt;br /&gt;
&lt;br /&gt;
==Journals==&lt;br /&gt;
&lt;br /&gt;
#[http://journals.lww.com/clinicalneurophys/pages/default.aspx  Journal of Clinical Neurophysiology] Official Journal of the American Clinical Neurophysiology Society.&lt;br /&gt;
#[http://www.journals.elsevier.com/clinical-neurophysiology Clinical Neurophysiology] The official journal of the International Federation of Clinical Neurophysiology. It is dedicated to fostering research and disseminating information on all aspects of Clinical Neurophysiology.&lt;br /&gt;
#[http://www.the-aps.org/mm/Publications/Journals/JN Journal of Neurophysiology] publishes original articles on the function of the nervous system, from American Physiological Society.&lt;br /&gt;
#[http://onlinelibrary.wiley.com/journal/10.1002/%28ISSN%291097-4598 Muscle &amp;amp; Nerve] Journal of American Association of Neuromuscular &amp;amp; Electrodiagnostic Medicine.&lt;br /&gt;
#[http://thejns.org/ Journal of Neurosurgery]&lt;br /&gt;
#[http://www.jneurosci.org/  The Journal of Neuroscience] published by Society for Neuroscience.&lt;br /&gt;
&lt;br /&gt;
==Web discussion forums==&lt;br /&gt;
&lt;br /&gt;
==Mailing lists==&lt;br /&gt;
#The Neuromonitoring mailing list - is for anyone with a professional or scientific interest in neuromonitoring. To subscribe, send email to listproc@usc.edu with the following request &amp;quot;subscribe NEUROMON-L Your Name&amp;quot;.&lt;br /&gt;
#[http://home.ease.lsoft.com/scripts/wa-HOME.exe?A0=EPILEPSY-L  EPILEPSY-L: Epilepsy support group] is an email based support group (discussion list) for people with epilepsy and those who care about and for them.&lt;br /&gt;
&lt;br /&gt;
==Study resources==&lt;br /&gt;
&lt;br /&gt;
#[http://www.ptcny.com/clients/ABNM/ABNM.html  Certification Examination in Neurophysiologic Monitoring] ABNM Board exam by American Board of Neurophysiologic Monitoring&lt;br /&gt;
#[http://www.ptcny.com/clients/ABRET/#Certification%20Examination%20in%20Neurophysiologic%20Intraoperative%20Monitoring Certification Examination in Neurophysiologic Intraoperative Monitoring] ABRET-CNIM by American Board of Registration of Electroencephalographic and Evoked Potential Technologists.&lt;br /&gt;
#[http://larryheadinstituteonline.com/lh/courses/ionm-training/ IONM Training] at Larry Head Institute&lt;br /&gt;
&lt;br /&gt;
==Jobs==&lt;br /&gt;
&lt;br /&gt;
#[http://www.asnm.org/?page=Careers Job postings] for ASNM memebers&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=General_Information&amp;diff=165</id>
		<title>General Information</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=General_Information&amp;diff=165"/>
		<updated>2014-06-23T20:02:54Z</updated>

		<summary type="html">&lt;p&gt;Bpw: /* Jobs */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Introduction==&lt;br /&gt;
&lt;br /&gt;
==Organizations==&lt;br /&gt;
&lt;br /&gt;
#[http://www.asnm.org American Society of Neurophysiological Monitoring]&lt;br /&gt;
#[http://www.acns.org American Clinical Neurophysiology Society]&lt;br /&gt;
#[http://www.aset.org The Neurodiagnostic Society (ASET)]&lt;br /&gt;
#[http://abnm.info American Board of Neurophysiologic Monitoring]&lt;br /&gt;
#[http://www.neurophysiology.org International Society of Intraoperative Neurophysiology (ISIN)]&lt;br /&gt;
#[http://www.ifcn.info International Federation of Clinical Neurophysiology]&lt;br /&gt;
#[http://www.aan.com  American Academy of Neurology]&lt;br /&gt;
#[http://www.oegkn.at/translat.htm Austrian Society for Clinical Neurophysiology]&lt;br /&gt;
#[http://www.neurofisiologia.net Italian Neurophysiological Technologists]&lt;br /&gt;
#[http://www.smnfc.com  Mexican Clinical Neurophysiology Society] Represents all certified clinical neurophysiologists in Mexico, with local and global event information in Spanish.&lt;br /&gt;
&lt;br /&gt;
==Conferences==&lt;br /&gt;
&lt;br /&gt;
#[http://asnm.site-ym.com/events/event_details.asp?id=326009 ASNM 2014 Annual Meeting] May 1-4, 2014, Fairmont Chicago Millennium Park, Chicago, Illinois&lt;br /&gt;
#[http://www.acns.org/meetings/annual-meeting-and-courses/2014/program American Clinical Neurophysiology Society Annual Meeting &amp;amp; Courses] February 4-9, 2014, Atlanta, Georgia.&lt;br /&gt;
#[http://www.isincapetown2013.com 4th International Conference on Intraoperative Neurophysiology] November 14-16, 2013, Cape Town, South Africa.&lt;br /&gt;
#[https://asnm.site-ym.com/?page=2013Annual ASNM 2013 Annual Meeting] Procedure Based IONM &amp;amp; State-Of-The-Art Scientific Discussion, May 2-5, 2013, Boston, Massachusetts.&lt;br /&gt;
&lt;br /&gt;
==Books==&lt;br /&gt;
#[http://www.amazon.com/Intraoperative-Neurophysiology-Mirela-Simon-MD-ebook/dp/B004MME2HY/tag=clinicalneurophy Intraoperative Neurophysiology] by Mirela Simon&lt;br /&gt;
#[http://www.amazon.com/Neurophysiology-Neurosurgery-Modern-Intraoperative-Approach/dp/0122090365/tag=clinicalneurophy Neurophysiology in Neurosurgery: A Modern Intraoperative Approach] by  Vedran Deletis and Jay Shils&lt;br /&gt;
#[http://www.amazon.com/Intraoperative-Neurophysiological-Monitoring-Aage-Møller/dp/1588297039/tag=clinicalneurophy Intraoperative Neurophysiological Monitoring] by Aage R. Møller&lt;br /&gt;
#[http://www.amazon.com/Intraoperative-Monitoring-Neural-Function-Neurophysiology/dp/044451824X/tag=clinicalneurophy Intraoperative Monitoring of Neural Function: Handbook of Clinical Neurophysiology] by  Marc R. Nuwer&lt;br /&gt;
&lt;br /&gt;
==Journals==&lt;br /&gt;
&lt;br /&gt;
#[http://journals.lww.com/clinicalneurophys/pages/default.aspx  Journal of Clinical Neurophysiology] Official Journal of the American Clinical Neurophysiology Society.&lt;br /&gt;
#[http://www.journals.elsevier.com/clinical-neurophysiology Clinical Neurophysiology] The official journal of the International Federation of Clinical Neurophysiology. It is dedicated to fostering research and disseminating information on all aspects of Clinical Neurophysiology.&lt;br /&gt;
#[http://www.the-aps.org/mm/Publications/Journals/JN Journal of Neurophysiology] publishes original articles on the function of the nervous system, from American Physiological Society.&lt;br /&gt;
#[http://onlinelibrary.wiley.com/journal/10.1002/%28ISSN%291097-4598 Muscle &amp;amp; Nerve] Journal of American Association of Neuromuscular &amp;amp; Electrodiagnostic Medicine.&lt;br /&gt;
#[http://thejns.org/ Journal of Neurosurgery]&lt;br /&gt;
#[http://www.jneurosci.org/  The Journal of Neuroscience] published by Society for Neuroscience.&lt;br /&gt;
&lt;br /&gt;
==Web discussion forums==&lt;br /&gt;
&lt;br /&gt;
==Mailing lists==&lt;br /&gt;
#The Neuromonitoring mailing list - is for anyone with a professional or scientific interest in neuromonitoring. To subscribe, send email to listproc@usc.edu with the following request &amp;quot;subscribe NEUROMON-L Your Name&amp;quot;.&lt;br /&gt;
#[http://home.ease.lsoft.com/scripts/wa-HOME.exe?A0=EPILEPSY-L  EPILEPSY-L: Epilepsy support group] is an email based support group (discussion list) for people with epilepsy and those who care about and for them.&lt;br /&gt;
&lt;br /&gt;
==Study resources==&lt;br /&gt;
&lt;br /&gt;
#[http://www.ptcny.com/clients/ABNM/ABNM.html  Certification Examination in Neurophysiologic Monitoring] ABNM Board exam by American Board of Neurophysiologic Monitoring&lt;br /&gt;
#[http://www.ptcny.com/clients/ABRET/#Certification%20Examination%20in%20Neurophysiologic%20Intraoperative%20Monitoring Certification Examination in Neurophysiologic Intraoperative Monitoring] ABRET-CNIM by American Board of Registration of Electroencephalographic and Evoked Potential Technologists.&lt;br /&gt;
#[http://larryheadinstituteonline.com/lh/courses/ionm-training/ IONM Training] at Larry Head Institute&lt;br /&gt;
&lt;br /&gt;
==Jobs==&lt;br /&gt;
&lt;br /&gt;
#[http://www.asnm.org/?page=Careers] Job postings for ASNM memebers&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=Main_Page&amp;diff=164</id>
		<title>Main Page</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=Main_Page&amp;diff=164"/>
		<updated>2014-06-23T19:59:22Z</updated>

		<summary type="html">&lt;p&gt;Bpw: /* NeurophysPedia : Intraoperative Neurophysiology */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
&lt;br /&gt;
= [[NeurophysPedia : Intraoperative Neurophysiology]] =&lt;br /&gt;
&lt;br /&gt;
Welcome to Neurophyspedia, the Wikipedia for intraoperative neurophysiology.&lt;br /&gt;
&lt;br /&gt;
== [[General Information]]==&lt;br /&gt;
&lt;br /&gt;
== [[Basic Neurophysiology]]  ==&lt;br /&gt;
&lt;br /&gt;
== [[Somatosensory Evoked Potentials (SSEP)]] ==&lt;br /&gt;
&lt;br /&gt;
== [[Motor Evoked Potentials (MEP)]] ==&lt;br /&gt;
&lt;br /&gt;
== [[Brainstem Auditory Evoked Responses (BAER)]] ==&lt;br /&gt;
&lt;br /&gt;
== [[Visual Evoked Potentials (VEP)]] ==&lt;br /&gt;
&lt;br /&gt;
== [[Electroencephalography (EEG)]] ==&lt;br /&gt;
&lt;br /&gt;
== [[Electromyography (EMG)]] ==&lt;br /&gt;
&lt;br /&gt;
== [[Intraoperative Neurophysiological Monitoring (IONM)]] ==&lt;br /&gt;
&lt;br /&gt;
== [[IONM in Cranial Surgery]] ==&lt;br /&gt;
&lt;br /&gt;
== [[IONM in Spinal Surgery]]==&lt;br /&gt;
&lt;br /&gt;
== [[IONM in Peripheral Nerve Surgery]]==&lt;br /&gt;
&lt;br /&gt;
== [[IONM in Vascular Surgery]]==&lt;br /&gt;
&lt;br /&gt;
== [[IONM in Otolaryngological or ENT Surgery]]==&lt;br /&gt;
 &lt;br /&gt;
== [[Neurophysiological Diagnostics]] ==&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=General_Information&amp;diff=163</id>
		<title>General Information</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=General_Information&amp;diff=163"/>
		<updated>2014-01-28T15:43:52Z</updated>

		<summary type="html">&lt;p&gt;Bpw: /* Conferences */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Introduction==&lt;br /&gt;
&lt;br /&gt;
==Organizations==&lt;br /&gt;
&lt;br /&gt;
#[http://www.asnm.org American Society of Neurophysiological Monitoring]&lt;br /&gt;
#[http://www.acns.org American Clinical Neurophysiology Society]&lt;br /&gt;
#[http://www.aset.org The Neurodiagnostic Society (ASET)]&lt;br /&gt;
#[http://abnm.info American Board of Neurophysiologic Monitoring]&lt;br /&gt;
#[http://www.neurophysiology.org International Society of Intraoperative Neurophysiology (ISIN)]&lt;br /&gt;
#[http://www.ifcn.info International Federation of Clinical Neurophysiology]&lt;br /&gt;
#[http://www.aan.com  American Academy of Neurology]&lt;br /&gt;
#[http://www.oegkn.at/translat.htm Austrian Society for Clinical Neurophysiology]&lt;br /&gt;
#[http://www.neurofisiologia.net Italian Neurophysiological Technologists]&lt;br /&gt;
#[http://www.smnfc.com  Mexican Clinical Neurophysiology Society] Represents all certified clinical neurophysiologists in Mexico, with local and global event information in Spanish.&lt;br /&gt;
&lt;br /&gt;
==Conferences==&lt;br /&gt;
&lt;br /&gt;
#[http://asnm.site-ym.com/events/event_details.asp?id=326009 ASNM 2014 Annual Meeting] May 1-4, 2014, Fairmont Chicago Millennium Park, Chicago, Illinois&lt;br /&gt;
#[http://www.acns.org/meetings/annual-meeting-and-courses/2014/program American Clinical Neurophysiology Society Annual Meeting &amp;amp; Courses] February 4-9, 2014, Atlanta, Georgia.&lt;br /&gt;
#[http://www.isincapetown2013.com 4th International Conference on Intraoperative Neurophysiology] November 14-16, 2013, Cape Town, South Africa.&lt;br /&gt;
#[https://asnm.site-ym.com/?page=2013Annual ASNM 2013 Annual Meeting] Procedure Based IONM &amp;amp; State-Of-The-Art Scientific Discussion, May 2-5, 2013, Boston, Massachusetts.&lt;br /&gt;
&lt;br /&gt;
==Books==&lt;br /&gt;
#[http://www.amazon.com/Intraoperative-Neurophysiology-Mirela-Simon-MD-ebook/dp/B004MME2HY/tag=clinicalneurophy Intraoperative Neurophysiology] by Mirela Simon&lt;br /&gt;
#[http://www.amazon.com/Neurophysiology-Neurosurgery-Modern-Intraoperative-Approach/dp/0122090365/tag=clinicalneurophy Neurophysiology in Neurosurgery: A Modern Intraoperative Approach] by  Vedran Deletis and Jay Shils&lt;br /&gt;
#[http://www.amazon.com/Intraoperative-Neurophysiological-Monitoring-Aage-Møller/dp/1588297039/tag=clinicalneurophy Intraoperative Neurophysiological Monitoring] by Aage R. Møller&lt;br /&gt;
#[http://www.amazon.com/Intraoperative-Monitoring-Neural-Function-Neurophysiology/dp/044451824X/tag=clinicalneurophy Intraoperative Monitoring of Neural Function: Handbook of Clinical Neurophysiology] by  Marc R. Nuwer&lt;br /&gt;
&lt;br /&gt;
==Journals==&lt;br /&gt;
&lt;br /&gt;
#[http://journals.lww.com/clinicalneurophys/pages/default.aspx  Journal of Clinical Neurophysiology] Official Journal of the American Clinical Neurophysiology Society.&lt;br /&gt;
#[http://www.journals.elsevier.com/clinical-neurophysiology Clinical Neurophysiology] The official journal of the International Federation of Clinical Neurophysiology. It is dedicated to fostering research and disseminating information on all aspects of Clinical Neurophysiology.&lt;br /&gt;
#[http://www.the-aps.org/mm/Publications/Journals/JN Journal of Neurophysiology] publishes original articles on the function of the nervous system, from American Physiological Society.&lt;br /&gt;
#[http://onlinelibrary.wiley.com/journal/10.1002/%28ISSN%291097-4598 Muscle &amp;amp; Nerve] Journal of American Association of Neuromuscular &amp;amp; Electrodiagnostic Medicine.&lt;br /&gt;
#[http://thejns.org/ Journal of Neurosurgery]&lt;br /&gt;
#[http://www.jneurosci.org/  The Journal of Neuroscience] published by Society for Neuroscience.&lt;br /&gt;
&lt;br /&gt;
==Web discussion forums==&lt;br /&gt;
&lt;br /&gt;
==Mailing lists==&lt;br /&gt;
#The Neuromonitoring mailing list - is for anyone with a professional or scientific interest in neuromonitoring. To subscribe, send email to listproc@usc.edu with the following request &amp;quot;subscribe NEUROMON-L Your Name&amp;quot;.&lt;br /&gt;
#[http://home.ease.lsoft.com/scripts/wa-HOME.exe?A0=EPILEPSY-L  EPILEPSY-L: Epilepsy support group] is an email based support group (discussion list) for people with epilepsy and those who care about and for them.&lt;br /&gt;
&lt;br /&gt;
==Study resources==&lt;br /&gt;
&lt;br /&gt;
#[http://www.ptcny.com/clients/ABNM/ABNM.html  Certification Examination in Neurophysiologic Monitoring] ABNM Board exam by American Board of Neurophysiologic Monitoring&lt;br /&gt;
#[http://www.ptcny.com/clients/ABRET/#Certification%20Examination%20in%20Neurophysiologic%20Intraoperative%20Monitoring Certification Examination in Neurophysiologic Intraoperative Monitoring] ABRET-CNIM by American Board of Registration of Electroencephalographic and Evoked Potential Technologists.&lt;br /&gt;
#[http://larryheadinstituteonline.com/lh/courses/ionm-training/ IONM Training] at Larry Head Institute&lt;br /&gt;
&lt;br /&gt;
==Jobs==&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=Help:Contents&amp;diff=158</id>
		<title>Help:Contents</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=Help:Contents&amp;diff=158"/>
		<updated>2013-11-26T20:29:17Z</updated>

		<summary type="html">&lt;p&gt;Bpw: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Welcome to NeurophysWiki! Here are few links to some useful information.&lt;br /&gt;
&lt;br /&gt;
#[http://meta.wikimedia.org/wiki/Help:Contents Wiki User Guide]&lt;br /&gt;
#[http://meta.wikimedia.org/wiki/Help:Editing Wiki Edting]&lt;br /&gt;
#[http://meta.wikimedia.org/wiki/Help:Wikitext_examples Wikitext Examples]&lt;br /&gt;
#[http://www.mediawiki.org/wiki/Manual:FAQ Wiki Manual: FAQ]&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=General_Information&amp;diff=153</id>
		<title>General Information</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=General_Information&amp;diff=153"/>
		<updated>2013-11-10T01:52:49Z</updated>

		<summary type="html">&lt;p&gt;Bpw: /* Conferences */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Introduction==&lt;br /&gt;
&lt;br /&gt;
==Organizations==&lt;br /&gt;
&lt;br /&gt;
#[http://www.asnm.org American Society of Neurophysiological Monitoring]&lt;br /&gt;
#[http://www.acns.org American Clinical Neurophysiology Society]&lt;br /&gt;
#[http://www.aset.org The Neurodiagnostic Society (ASET)]&lt;br /&gt;
#[http://abnm.info American Board of Neurophysiologic Monitoring]&lt;br /&gt;
#[http://www.neurophysiology.org International Society of Intraoperative Neurophysiology (ISIN)]&lt;br /&gt;
#[http://www.ifcn.info International Federation of Clinical Neurophysiology]&lt;br /&gt;
#[http://www.aan.com  American Academy of Neurology]&lt;br /&gt;
#[http://www.oegkn.at/translat.htm Austrian Society for Clinical Neurophysiology]&lt;br /&gt;
#[http://www.neurofisiologia.net Italian Neurophysiological Technologists]&lt;br /&gt;
#[http://www.smnfc.com  Mexican Clinical Neurophysiology Society] Represents all certified clinical neurophysiologists in Mexico, with local and global event information in Spanish.&lt;br /&gt;
&lt;br /&gt;
==Conferences==&lt;br /&gt;
&lt;br /&gt;
#[https://asnm.site-ym.com/?page=2013Annual ASNM 2013 Annual Meeting] Procedure Based IONM &amp;amp; State-Of-The-Art Scientific Discussion, May 2-5, 2013, Boston, Massachusetts.&lt;br /&gt;
#[http://www.isincapetown2013.com 4th International Conference on Intraoperative Neurophysiology] November 14-16, 2013, Cape Town, South Africa.&lt;br /&gt;
#[http://www.acns.org/meetings/annual-meeting-and-courses/2014/program American Clinical Neurophysiology Society Annual Meeting &amp;amp; Courses] February 4-9, 2014, Atlanta, Georgia.&lt;br /&gt;
&lt;br /&gt;
==Books==&lt;br /&gt;
#[http://www.amazon.com/Intraoperative-Neurophysiology-Mirela-Simon-MD-ebook/dp/B004MME2HY/tag=clinicalneurophy Intraoperative Neurophysiology] by Mirela Simon&lt;br /&gt;
#[http://www.amazon.com/Neurophysiology-Neurosurgery-Modern-Intraoperative-Approach/dp/0122090365/tag=clinicalneurophy Neurophysiology in Neurosurgery: A Modern Intraoperative Approach] by  Vedran Deletis and Jay Shils&lt;br /&gt;
#[http://www.amazon.com/Intraoperative-Neurophysiological-Monitoring-Aage-Møller/dp/1588297039/tag=clinicalneurophy Intraoperative Neurophysiological Monitoring] by Aage R. Møller&lt;br /&gt;
#[http://www.amazon.com/Intraoperative-Monitoring-Neural-Function-Neurophysiology/dp/044451824X/tag=clinicalneurophy Intraoperative Monitoring of Neural Function: Handbook of Clinical Neurophysiology] by  Marc R. Nuwer&lt;br /&gt;
&lt;br /&gt;
==Journals==&lt;br /&gt;
&lt;br /&gt;
#[http://journals.lww.com/clinicalneurophys/pages/default.aspx  Journal of Clinical Neurophysiology] Official Journal of the American Clinical Neurophysiology Society.&lt;br /&gt;
#[http://www.journals.elsevier.com/clinical-neurophysiology Clinical Neurophysiology] The official journal of the International Federation of Clinical Neurophysiology. It is dedicated to fostering research and disseminating information on all aspects of Clinical Neurophysiology.&lt;br /&gt;
#[http://www.the-aps.org/mm/Publications/Journals/JN Journal of Neurophysiology] publishes original articles on the function of the nervous system, from American Physiological Society.&lt;br /&gt;
#[http://onlinelibrary.wiley.com/journal/10.1002/%28ISSN%291097-4598 Muscle &amp;amp; Nerve] Journal of American Association of Neuromuscular &amp;amp; Electrodiagnostic Medicine.&lt;br /&gt;
#[http://thejns.org/ Journal of Neurosurgery]&lt;br /&gt;
#[http://www.jneurosci.org/  The Journal of Neuroscience] published by Society for Neuroscience.&lt;br /&gt;
&lt;br /&gt;
==Web discussion forums==&lt;br /&gt;
&lt;br /&gt;
==Mailing lists==&lt;br /&gt;
#The Neuromonitoring mailing list - is for anyone with a professional or scientific interest in neuromonitoring. To subscribe, send email to listproc@usc.edu with the following request &amp;quot;subscribe NEUROMON-L Your Name&amp;quot;.&lt;br /&gt;
#[http://home.ease.lsoft.com/scripts/wa-HOME.exe?A0=EPILEPSY-L  EPILEPSY-L: Epilepsy support group] is an email based support group (discussion list) for people with epilepsy and those who care about and for them.&lt;br /&gt;
&lt;br /&gt;
==Study resources==&lt;br /&gt;
&lt;br /&gt;
#[http://www.ptcny.com/clients/ABNM/ABNM.html  Certification Examination in Neurophysiologic Monitoring] ABNM Board exam by American Board of Neurophysiologic Monitoring&lt;br /&gt;
#[http://www.ptcny.com/clients/ABRET/#Certification%20Examination%20in%20Neurophysiologic%20Intraoperative%20Monitoring Certification Examination in Neurophysiologic Intraoperative Monitoring] ABRET-CNIM by American Board of Registration of Electroencephalographic and Evoked Potential Technologists.&lt;br /&gt;
#[http://larryheadinstituteonline.com/lh/courses/ionm-training/ IONM Training] at Larry Head Institute&lt;br /&gt;
&lt;br /&gt;
==Jobs==&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=General_Information&amp;diff=152</id>
		<title>General Information</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=General_Information&amp;diff=152"/>
		<updated>2013-11-04T19:48:13Z</updated>

		<summary type="html">&lt;p&gt;Bpw: /* Books */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Introduction==&lt;br /&gt;
&lt;br /&gt;
==Organizations==&lt;br /&gt;
&lt;br /&gt;
#[http://www.asnm.org American Society of Neurophysiological Monitoring]&lt;br /&gt;
#[http://www.acns.org American Clinical Neurophysiology Society]&lt;br /&gt;
#[http://www.aset.org The Neurodiagnostic Society (ASET)]&lt;br /&gt;
#[http://abnm.info American Board of Neurophysiologic Monitoring]&lt;br /&gt;
#[http://www.neurophysiology.org International Society of Intraoperative Neurophysiology (ISIN)]&lt;br /&gt;
#[http://www.ifcn.info International Federation of Clinical Neurophysiology]&lt;br /&gt;
#[http://www.aan.com  American Academy of Neurology]&lt;br /&gt;
#[http://www.oegkn.at/translat.htm Austrian Society for Clinical Neurophysiology]&lt;br /&gt;
#[http://www.neurofisiologia.net Italian Neurophysiological Technologists]&lt;br /&gt;
#[http://www.smnfc.com  Mexican Clinical Neurophysiology Society] Represents all certified clinical neurophysiologists in Mexico, with local and global event information in Spanish.&lt;br /&gt;
&lt;br /&gt;
==Conferences==&lt;br /&gt;
&lt;br /&gt;
#[https://asnm.site-ym.com/?page=2013Annual ASNM 2013 Annual Meeting] Procedure Based IONM &amp;amp; State-Of-The-Art Scientific Discussion, May 2-5, 2013, Boston, Massachusetts.&lt;br /&gt;
#[http://www.isincapetown2013.com 4th International Conference on Intraoperative Neurophysiology] November 14-16, 2013, Cape Town, South Africa.&lt;br /&gt;
&lt;br /&gt;
==Books==&lt;br /&gt;
#[http://www.amazon.com/Intraoperative-Neurophysiology-Mirela-Simon-MD-ebook/dp/B004MME2HY/tag=clinicalneurophy Intraoperative Neurophysiology] by Mirela Simon&lt;br /&gt;
#[http://www.amazon.com/Neurophysiology-Neurosurgery-Modern-Intraoperative-Approach/dp/0122090365/tag=clinicalneurophy Neurophysiology in Neurosurgery: A Modern Intraoperative Approach] by  Vedran Deletis and Jay Shils&lt;br /&gt;
#[http://www.amazon.com/Intraoperative-Neurophysiological-Monitoring-Aage-Møller/dp/1588297039/tag=clinicalneurophy Intraoperative Neurophysiological Monitoring] by Aage R. Møller&lt;br /&gt;
#[http://www.amazon.com/Intraoperative-Monitoring-Neural-Function-Neurophysiology/dp/044451824X/tag=clinicalneurophy Intraoperative Monitoring of Neural Function: Handbook of Clinical Neurophysiology] by  Marc R. Nuwer&lt;br /&gt;
&lt;br /&gt;
==Journals==&lt;br /&gt;
&lt;br /&gt;
#[http://journals.lww.com/clinicalneurophys/pages/default.aspx  Journal of Clinical Neurophysiology] Official Journal of the American Clinical Neurophysiology Society.&lt;br /&gt;
#[http://www.journals.elsevier.com/clinical-neurophysiology Clinical Neurophysiology] The official journal of the International Federation of Clinical Neurophysiology. It is dedicated to fostering research and disseminating information on all aspects of Clinical Neurophysiology.&lt;br /&gt;
#[http://www.the-aps.org/mm/Publications/Journals/JN Journal of Neurophysiology] publishes original articles on the function of the nervous system, from American Physiological Society.&lt;br /&gt;
#[http://onlinelibrary.wiley.com/journal/10.1002/%28ISSN%291097-4598 Muscle &amp;amp; Nerve] Journal of American Association of Neuromuscular &amp;amp; Electrodiagnostic Medicine.&lt;br /&gt;
#[http://thejns.org/ Journal of Neurosurgery]&lt;br /&gt;
#[http://www.jneurosci.org/  The Journal of Neuroscience] published by Society for Neuroscience.&lt;br /&gt;
&lt;br /&gt;
==Web discussion forums==&lt;br /&gt;
&lt;br /&gt;
==Mailing lists==&lt;br /&gt;
#The Neuromonitoring mailing list - is for anyone with a professional or scientific interest in neuromonitoring. To subscribe, send email to listproc@usc.edu with the following request &amp;quot;subscribe NEUROMON-L Your Name&amp;quot;.&lt;br /&gt;
#[http://home.ease.lsoft.com/scripts/wa-HOME.exe?A0=EPILEPSY-L  EPILEPSY-L: Epilepsy support group] is an email based support group (discussion list) for people with epilepsy and those who care about and for them.&lt;br /&gt;
&lt;br /&gt;
==Study resources==&lt;br /&gt;
&lt;br /&gt;
#[http://www.ptcny.com/clients/ABNM/ABNM.html  Certification Examination in Neurophysiologic Monitoring] ABNM Board exam by American Board of Neurophysiologic Monitoring&lt;br /&gt;
#[http://www.ptcny.com/clients/ABRET/#Certification%20Examination%20in%20Neurophysiologic%20Intraoperative%20Monitoring Certification Examination in Neurophysiologic Intraoperative Monitoring] ABRET-CNIM by American Board of Registration of Electroencephalographic and Evoked Potential Technologists.&lt;br /&gt;
#[http://larryheadinstituteonline.com/lh/courses/ionm-training/ IONM Training] at Larry Head Institute&lt;br /&gt;
&lt;br /&gt;
==Jobs==&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=NeurophysPedia:Current_events&amp;diff=151</id>
		<title>NeurophysPedia:Current events</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=NeurophysPedia:Current_events&amp;diff=151"/>
		<updated>2013-11-04T17:35:37Z</updated>

		<summary type="html">&lt;p&gt;Bpw: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;#[https://asnm.site-ym.com/?page=2013Annual ASNM 2013 Annual Meeting] Procedure Based IONM &amp;amp; State-Of-The-Art Scientific Discussion, May 2-5, 2013, Boston, Massachusetts.&lt;br /&gt;
#[http://www.isincapetown2013.com 4th International Conference on Intraoperative Neurophysiology] November 14-16, 2013, Cape Town, South Africa.&lt;br /&gt;
#[http://www.acns.org/meetings/annual-meeting-and-courses/2014/program American Clinical Neurophysiology Society Annual Meeting &amp;amp; Courses] February 4-9, Atlanta, Georgia.&lt;br /&gt;
#[http://www.asnm.org/events/event_details.asp?id=338883 ASNM 2014 Winter Symposium] February 22-23, 2014, Tampa, Florida.&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=NeurophysPedia:Current_events&amp;diff=150</id>
		<title>NeurophysPedia:Current events</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=NeurophysPedia:Current_events&amp;diff=150"/>
		<updated>2013-11-04T17:30:12Z</updated>

		<summary type="html">&lt;p&gt;Bpw: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;#[https://asnm.site-ym.com/?page=2013Annual ASNM 2013 Annual Meeting] Procedure Based IONM &amp;amp; State-Of-The-Art Scientific Discussion, May 2-5, 2013, Boston, Massachusetts.&lt;br /&gt;
#[http://www.isincapetown2013.com 4th International Conference on Intraoperative Neurophysiology] November 14-16, 2013, Cape Town, South Africa.&lt;br /&gt;
#[http://www.acns.org/meetings/annual-meeting-and-courses/2014/program American Clinical Neurophysiology Society Annual Meeting &amp;amp; Courses] February 4-9, Atlanta, Georgia.&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=Somatosensory_Evoked_Potentials_(SSEP)&amp;diff=149</id>
		<title>Somatosensory Evoked Potentials (SSEP)</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=Somatosensory_Evoked_Potentials_(SSEP)&amp;diff=149"/>
		<updated>2013-11-04T17:01:23Z</updated>

		<summary type="html">&lt;p&gt;Bpw: /* References */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Somatosensory evoked potentials (SSEP) are recorded from the central nervous system following stimulation of peripheral nerves.&lt;br /&gt;
&lt;br /&gt;
== Introduction==&lt;br /&gt;
&lt;br /&gt;
Somatosensory Evoked Potentials (SSEPs) are electric signals recorded from the scalp or spine following stimulation to the peripheral nerves. They are time-locked responses, representing the function of the ascending sensory pathways. Early in the 1960s Larson et al introduced the use of somatosensory evoked potentials to monitor neural structure during neurosurgical procedures. It was utilized as a supplement to the wake-up test during correctional spinal surgeries for spinal deformities such as scoliosis to provide warning of compromised spinal cord function to the spine surgeons, as reported by McCallum et al and Nash et al in the 1970s. Since then SSEP has become one of the earliest and primary tools for intraoperative neurophysiological monitoring.&lt;br /&gt;
&lt;br /&gt;
== Somatosensory Pathways ==&lt;br /&gt;
[[Image:Ascending Pathways.jpg|right|100px|200px]]&lt;br /&gt;
&lt;br /&gt;
Distal peripheral nerves are stimulated for SSEP recordings; typically the median or ulnar nerve at the wrist for upper extremity SSEPs, or posterior tibial nerve at the ankle for lower extremity SSEPs. The ascending sensory volley enters the spinal cord through dorsal nerve roots. Multiple dorsal or posterior column spinal pathways such as the gracile fasciculus (legs and trunk) and the cuneate fasciculus (arms and trunk) mediate the SSEP responses. They arrive at the medulla and make synaptic connection at the medullary nuclei (nucleus cuneatus and nucleus gracilis). From there they cross and ascend in the medial lemniscal pathways to thalamic nuclei, which in turn project up to the somatosenory cortex.&lt;br /&gt;
&lt;br /&gt;
There is no synapses between the peripheral stimulation sites and the medullary nuclei. Synapses are the sites of action for inhalational anesthetic agents. Therefore any SSEP responses recorded below the level of medullary nuclei are affected only minimally by general anesthesia. The cortical SSEP responses, however, are greatly affected by inhalational agents; whichever recorded anesthetic management is very much required.&lt;br /&gt;
&lt;br /&gt;
== Stimulation ==&lt;br /&gt;
#&#039;&#039;&#039;Stimulation Sites&#039;&#039;&#039;: SSEPs may be elicited by electrical stimulation to major nerve trunks or dermatomes. Upper extremity mixed or major nerve SSEPs are typically obtained by stimulating the median nerve or ulnar nerve near the wrist; or sometimes the ulnar nerve at the elbow. Lower extremity SSEPs are normally recorded to stimulation of the posterior tibial nerve at the ankle, or peroneal nerve near the head of the fibula at the knee. Usually the anode electrode should be placed 2-4 cm distal to the cathode electrode to avoid anodal block.&lt;br /&gt;
#&#039;&#039;&#039;Electrodes&#039;&#039;&#039;: Subdermal needle electrodes or adhesive surface electrodes are most commonly used for intraoperative SSEP recordings. Some other types of electrodes such as bar electrodes and EEG metal disc electrodes are more suitable for diagnostic SSEP recordings in the lab. Needle electrodes can be placed closer to the underlying nerves than surface electrodes; however they are associated with additional risks of infection, bleeding, and inadvertent needle sticks.&lt;br /&gt;
#&#039;&#039;&#039;Constant Current vs Constant Voltage&#039;&#039;&#039;: Constant current stimulation is recommended for consistent and reliable stimulation for optimal SSEP recording in the OR, especially for long surgical procedures. Constant current stimuli may compensate for any changes in electrical conductivity, or electrode contact resistance.&lt;br /&gt;
#&#039;&#039;&#039;Stimulation Parameters&#039;&#039;&#039;: a series of rectangular pulses with certain pulse width and frequency are typically used as electrical stimuli for SSEP recording. &lt;br /&gt;
##&#039;&#039;&#039;Pulse width (or pulse duration)&#039;&#039;&#039;: 200-300 microsecond is suggested  &lt;br /&gt;
##&#039;&#039;&#039;Frequency (or rep rate)&#039;&#039;&#039;: Higher stimulus rate is desired for quick acquisition of SSEP responses in the operating room. However increasing the rate too high may result in degradation of the responses; also it is limited when interleaving stimulation of 2 or 4 limbs. In general a frequency between 2 and 5 Hz are recommended. To avoid synchronization between the responses and the underlying electrical noise, most commonly 60Hz or 50Hz in different countries, the stimulus rate should not be a submultiple of the noise frequency. Sometimes a slight change of stimulus rate, for example from 4.80 to 4.13, may improve the quality of the evoked responses.&lt;br /&gt;
##&#039;&#039;&#039;Intensity&#039;&#039;&#039;: Supramaximal stimulation should be used to produce repeatable responses. Some factors, such as pathology of the peripheral nerves, large or edematous extremities, distance of the electrodes to the underlying nerves, types of stimulating electrodes, may limit the effectiveness of stimulation. A stimulus of 50mA or greater is required sometimes. There is concern of tissue damage from high current densities at the stimulation site which is rare.&lt;br /&gt;
&lt;br /&gt;
== Recording Techniques ==&lt;br /&gt;
&lt;br /&gt;
#&#039;&#039;&#039;Electrodes&#039;&#039;&#039;: Metal surface cup electrodes are non-invasive electrodes, which can be applied with conductive gel after skin preparation. Subdermal needles are also commonly used in the operating room; some are available with angled or hooked tips. A corkscrew version can be screwed into the scalp for prolonged recording, however excessive bleeding can be a concern. For direct cortical mapping and recording, a strip or grid electrode array can be used for cranial surgeries. &lt;br /&gt;
#&#039;&#039;&#039;Recording Sites&#039;&#039;&#039;&lt;br /&gt;
##Cortical recording of upper extremity SSEP: It is the post-central gyrus of somatosensory cortex, contralateral to the stimulated limb. The locations are called CP3 and CP4 which are 2 cm posterior to the C3 and C4 positions of the 10-20 International System of EEG electrode placement. The recording montage can be CP3-Fz or CP3-CP4 for right arm stimulation; CP4-Fz or CP4-CP3 for left arm stimulation.&lt;br /&gt;
##Cortical recording of lower extremity SSEP: CPz is the active electrode site, which is 2 cm posterior to Cz. The traditional derivation of recording is CPz-Fz; however it should not be the only standard recording derivation, according to studies for optimized lower extremity SSEP recording by MacDonald DB et al and many others. Often time CPz-CPc (which is CPz-CP4 for left leg stimulation, and CPz-CP3 for right) may produce higher amplitude and more reliable signals.&lt;br /&gt;
##Subcortical: The recording can be made at posterior cervical spine, one or linked earlobes, or mastoid. Subcortical responses are less affected by inhalational agents. However, the subcortical SSEP response is normally very well defined for upper extremity stimulation, it is often poorly defined for lower extremity stimulation.&lt;br /&gt;
##Peripheral nerve: Usually it is the ipsilateral Erb&#039;s point for upper extremity stimulation, and ipsilateral popliteal fossa for lower extremity stimulation. This is done to verify the status of the peripheral stimulation.&lt;br /&gt;
#&#039;&#039;&#039;Averaging:&#039;&#039;&#039; The SSEP amplitudes tend to be low; as high as only several microvolts, or as low as less than a microvolts especially with pathological subjects. Averaging is required to record the signal against biological and ambient noise. SSEP signal is time-locked to the stimulus and most of the noise occurs randomly, allowing the noise to be averaged out with averaging of repeated responses. Some earlier guidelines such as that from American EEG Society suggested acquiring 500-2000 trails per averaged response. However for surgical monitoring well defined evoked potentials should be acquired as quickly as possible. With good preparation of the recording sites to reduce impedance, and optimized recording montages, clean signals could be recorded as few as 50-200 trials. &lt;br /&gt;
#&#039;&#039;&#039;Recording Parameters&#039;&#039;&#039;&lt;br /&gt;
##Filters: More environmental noise in the operating room and necessity of quick acquisition make it important to choose optimal filter settings, different from laboratory SSEP diagnostic studies. The majority of the energy contained in cortical SSEP is present in the frequency bandpass above 30Hz and below 500Hz; filters can be set to (10-30) Hz to (250-1000) Hz. The relative frequency content of the subcortical or peripheral responses is much higher, thus the filters can be set to (30-100)Hz to (500-2000) Hz.&lt;br /&gt;
##Timebase: The timebase is usually set at 50 milliseconds for upper extremity SSEPs, and 100 milliseconds for upper extremity SSEPs. It is based on the normal conduction time between the stimulation and recording sites. It may need adjustment depending on the age and size of the individual, and any pathological conditions.&lt;br /&gt;
##Sensitivity: The median amplitude of SSEP is about 1 microvolt. The recording sensitivity could range from 0.1 to 5 microvolts/unit. With direct cortical recording during cranial surgeries, the amplitude can be high and the sensitivity my be set to 20-50 microvolts/unit.&lt;br /&gt;
##Sweep delay: Normally it should be avoided to use sweep delay. However it may be necessary when large stimulus artifact is present.&lt;br /&gt;
##Interleaving recording: Alternating recording of SSEP responses to stimulation of 2 or 4 limbs at the same time is available with modern recording devices from different manufacturers.&lt;br /&gt;
&lt;br /&gt;
== Waveforms ==&lt;br /&gt;
&#039;&#039;&#039;Upper Extremity SSEPs&#039;&#039;&#039;&lt;br /&gt;
#N9: Recorded from ipsilateral Erb&#039;s point, and sometimes it&#039;s called EP. It is a compound action potential from the axons to the median nerve or ulnar nerve stimulation.&lt;br /&gt;
#N13-P14: Cervical potentials, recorded near C5 spinal process. The origin is thought to be dorsal horn neurons, and the caudal medial lemniscus.&lt;br /&gt;
#N20-P23: Scalp potentials, generated from the thalamocortical radiations.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Lower Extremity SSEPs&#039;&#039;&#039;&lt;br /&gt;
#LP: Recorded from the T12 spinal process, arise from the afferent nerve volley in the dorsal roots and dorsal root entry zone.&lt;br /&gt;
#N34: Recorded at the cervical spine; the amplitude can be very low and difficult to identify. The origin is thought to be brainstem or perhaps thalamus.&lt;br /&gt;
#P37-N45: Scalp potentials, reflect activation of the primary somatosensory cortex.&lt;br /&gt;
&lt;br /&gt;
[[Image:SSEP Waveforms.jpg|center|2000px|750px]]&lt;br /&gt;
&lt;br /&gt;
== Intraoperative Monitoring ==&lt;br /&gt;
The basic principle of intraoperative monitoring with mixed nerve SSEP is to stimulate nerves distal to the surgical site, and to record responses proximal to the surgical site. In most cases, these recording sites should include one cortical and one subcortical recording site.&lt;br /&gt;
&lt;br /&gt;
#&#039;&#039;&#039;Data acquisition&#039;&#039;&#039;: Baseline SSEP responses should be established, ideally after induction and before patient positioning and surgical incision. Data should be collected throughout the surgical procedure, with corresponding documentation of surgical events such as incision, exposure, decompression, instrumentation, closure, etc. In addition, relevant physiological variables such as blood pressure and temperature changes, anesthetic agents being used and the levels, significant signal changes during the surgery and any communication and interventions should be documented.&lt;br /&gt;
#&#039;&#039;&#039;Alert criteria&#039;&#039;&#039;: Significant signal changes, with 50% decrease of peak to peak amplitude and 10% increase of latency, may be indication of nervous system functional changes and should be reported to the operating surgeon, and call for possible intervention.&lt;br /&gt;
&lt;br /&gt;
Depending on the specific surgery, planing is required to monitor the part of the nervous system at risk.&lt;br /&gt;
#&#039;&#039;&#039;Peripheral nerve and plexus&#039;&#039;&#039;&lt;br /&gt;
#&#039;&#039;&#039;Spinal nerve root&#039;&#039;&#039;&lt;br /&gt;
#&#039;&#039;&#039;Spinal cord&#039;&#039;&#039;&lt;br /&gt;
#&#039;&#039;&#039;Brainstem and thalamus&#039;&#039;&#039;&lt;br /&gt;
#&#039;&#039;&#039;Brain&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
== Systemic and Anesthesia Factors ==&lt;br /&gt;
#&#039;&#039;&#039;Temperature&#039;&#039;&#039;&lt;br /&gt;
#&#039;&#039;&#039;Blood pressure&#039;&#039;&#039;&lt;br /&gt;
#&#039;&#039;&#039;Halogenated inhalational agents&#039;&#039;&#039;&lt;br /&gt;
#&#039;&#039;&#039;Nitrous oxide&#039;&#039;&#039;&lt;br /&gt;
#&#039;&#039;&#039;Intravenous analgesic agents&#039;&#039;&#039;&lt;br /&gt;
#&#039;&#039;&#039;Muscle relaxants&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
==References==&lt;br /&gt;
# Brown RH, Nash CL, Berilla JA, Amaddio MD. Cortical evoked potential monitoring. A system for intraoperative monitoring of spinal cord function. Spine 1984; 9: 256-261.&lt;br /&gt;
# Celesia GG. Somatosensory evoked potentials recorded directly from human thalamus and Sm I cortical area. Arch Neurol 1979; 36: 399-405.&lt;br /&gt;
# Cohen AR, Young W, Ransohoff J. Intraspinal localization of the somatosensory evoked potential. Neurosurgery 1981; 9: 157-62.&lt;br /&gt;
# Kelly DL Jr, Goldring S, O’Leary JL. Averaged evoked somatosensory responses from exposed cortex of man. Arch Neurol 1965; 13: 1-9.&lt;br /&gt;
# Larson SJ, Sances A. Evoked potentials in man: neurosurgical applications. Am J Surg 1966; 111: 857-861.&lt;br /&gt;
# MacDonald DB. Individually optimizing posterior tibial somatosensory evoked potential P37 scalp derivations for intraoperative monitoring. J Clin Neurophysiol. 2001 Jul;18(4):364-71.&lt;br /&gt;
# Mauguiere F. Anatomic origin of the cervical N13 potential evoked by upper extremity stimulation. J of Clin Neurophysiology 2000; 17: 236-245.&lt;br /&gt;
# McCallum JE, Bennett MH. Electrophysiologic monitoring of spinal cord function during intraspinal surgery. Surg Forum 1975; 26: 469-471.&lt;br /&gt;
# Nash CL, Long RA, Schatzinger LA, Brown RH. Spinal cord monitoring during operative treatment of the spine. Clin Orthop 1977; 126: 100-105.&lt;br /&gt;
# Nuwer MR, Dawson EG, Carlson LG, Kanim LEA, Sherman JE. Somatosensory evoked potential spinal cord monitoring reduces neurologic deficits after scoliosis surgery: results of a large multicenter survey. Electroencepholog and Clin Neurophysiol 1995; 96: 6-11.&lt;br /&gt;
# Nuwer MR, et al. IFCN recommended standards for short latency somatosensory evoked potentials. Report of an IFCN committee. Electroencephalography and Clinical Neurophysiology 1994; 91: 6-11.&lt;br /&gt;
# Powers SK, Bolger CA, Edwards MSB. Spinal cord pathways mediating somatosensory evoked potentials. J Neurosurg 1982; 57: 472-82.&lt;br /&gt;
# Simpson RK JR, Blackburn JG, Martin HF III, Katz S. Peripheral nerve fibers and spinal cord pathway contribution to the somatosensory evoked potentials. Exp Neurol 1981; 73: 700-15.&lt;br /&gt;
# Sloan TB. Anesthetic Effects on Electrophysiologic Recordings. Journal of Clinical Neurophysiology 1998; 15: 217-226.&lt;br /&gt;
# Toleikis JR. Intraoperative monitoring using somatosensory evoked potentials: A position statement by the American Society of Neurophysiological Monitoring. J Clin Monit Comput. 2005; 19(3):241-58.&lt;br /&gt;
# Wang BP, Turner LA, Kamp AM, Venier LH. CPz-CP4 and CPz-CP3 are superior to CPz-FPz for recording left and right tibial nerve somatosensory evoked potentials for intraoperative monitoring. A review study in 264 patients. 2006 The 17th Annual Meeting of American Society of Neurophysiological Monitoring.&lt;br /&gt;
# Yanni DS, Ulkatan S, Deletis V, Barrenechea IJ, Sen C, Perin NI. Utility of neurophysiological monitoring using dorsal column mapping in intramedullary spinal cord surgery. J Neurosurg Spine. 2010;12:623-628.&lt;br /&gt;
# York DH, Chabot RJ, Gaines RW. Response variability of somatosensory evoked potentials during scoliosis surgery. Spine 1987; 12: 864-876.&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=Somatosensory_Evoked_Potentials_(SSEP)&amp;diff=148</id>
		<title>Somatosensory Evoked Potentials (SSEP)</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=Somatosensory_Evoked_Potentials_(SSEP)&amp;diff=148"/>
		<updated>2013-11-04T17:00:28Z</updated>

		<summary type="html">&lt;p&gt;Bpw: /* References */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Somatosensory evoked potentials (SSEP) are recorded from the central nervous system following stimulation of peripheral nerves.&lt;br /&gt;
&lt;br /&gt;
== Introduction==&lt;br /&gt;
&lt;br /&gt;
Somatosensory Evoked Potentials (SSEPs) are electric signals recorded from the scalp or spine following stimulation to the peripheral nerves. They are time-locked responses, representing the function of the ascending sensory pathways. Early in the 1960s Larson et al introduced the use of somatosensory evoked potentials to monitor neural structure during neurosurgical procedures. It was utilized as a supplement to the wake-up test during correctional spinal surgeries for spinal deformities such as scoliosis to provide warning of compromised spinal cord function to the spine surgeons, as reported by McCallum et al and Nash et al in the 1970s. Since then SSEP has become one of the earliest and primary tools for intraoperative neurophysiological monitoring.&lt;br /&gt;
&lt;br /&gt;
== Somatosensory Pathways ==&lt;br /&gt;
[[Image:Ascending Pathways.jpg|right|100px|200px]]&lt;br /&gt;
&lt;br /&gt;
Distal peripheral nerves are stimulated for SSEP recordings; typically the median or ulnar nerve at the wrist for upper extremity SSEPs, or posterior tibial nerve at the ankle for lower extremity SSEPs. The ascending sensory volley enters the spinal cord through dorsal nerve roots. Multiple dorsal or posterior column spinal pathways such as the gracile fasciculus (legs and trunk) and the cuneate fasciculus (arms and trunk) mediate the SSEP responses. They arrive at the medulla and make synaptic connection at the medullary nuclei (nucleus cuneatus and nucleus gracilis). From there they cross and ascend in the medial lemniscal pathways to thalamic nuclei, which in turn project up to the somatosenory cortex.&lt;br /&gt;
&lt;br /&gt;
There is no synapses between the peripheral stimulation sites and the medullary nuclei. Synapses are the sites of action for inhalational anesthetic agents. Therefore any SSEP responses recorded below the level of medullary nuclei are affected only minimally by general anesthesia. The cortical SSEP responses, however, are greatly affected by inhalational agents; whichever recorded anesthetic management is very much required.&lt;br /&gt;
&lt;br /&gt;
== Stimulation ==&lt;br /&gt;
#&#039;&#039;&#039;Stimulation Sites&#039;&#039;&#039;: SSEPs may be elicited by electrical stimulation to major nerve trunks or dermatomes. Upper extremity mixed or major nerve SSEPs are typically obtained by stimulating the median nerve or ulnar nerve near the wrist; or sometimes the ulnar nerve at the elbow. Lower extremity SSEPs are normally recorded to stimulation of the posterior tibial nerve at the ankle, or peroneal nerve near the head of the fibula at the knee. Usually the anode electrode should be placed 2-4 cm distal to the cathode electrode to avoid anodal block.&lt;br /&gt;
#&#039;&#039;&#039;Electrodes&#039;&#039;&#039;: Subdermal needle electrodes or adhesive surface electrodes are most commonly used for intraoperative SSEP recordings. Some other types of electrodes such as bar electrodes and EEG metal disc electrodes are more suitable for diagnostic SSEP recordings in the lab. Needle electrodes can be placed closer to the underlying nerves than surface electrodes; however they are associated with additional risks of infection, bleeding, and inadvertent needle sticks.&lt;br /&gt;
#&#039;&#039;&#039;Constant Current vs Constant Voltage&#039;&#039;&#039;: Constant current stimulation is recommended for consistent and reliable stimulation for optimal SSEP recording in the OR, especially for long surgical procedures. Constant current stimuli may compensate for any changes in electrical conductivity, or electrode contact resistance.&lt;br /&gt;
#&#039;&#039;&#039;Stimulation Parameters&#039;&#039;&#039;: a series of rectangular pulses with certain pulse width and frequency are typically used as electrical stimuli for SSEP recording. &lt;br /&gt;
##&#039;&#039;&#039;Pulse width (or pulse duration)&#039;&#039;&#039;: 200-300 microsecond is suggested  &lt;br /&gt;
##&#039;&#039;&#039;Frequency (or rep rate)&#039;&#039;&#039;: Higher stimulus rate is desired for quick acquisition of SSEP responses in the operating room. However increasing the rate too high may result in degradation of the responses; also it is limited when interleaving stimulation of 2 or 4 limbs. In general a frequency between 2 and 5 Hz are recommended. To avoid synchronization between the responses and the underlying electrical noise, most commonly 60Hz or 50Hz in different countries, the stimulus rate should not be a submultiple of the noise frequency. Sometimes a slight change of stimulus rate, for example from 4.80 to 4.13, may improve the quality of the evoked responses.&lt;br /&gt;
##&#039;&#039;&#039;Intensity&#039;&#039;&#039;: Supramaximal stimulation should be used to produce repeatable responses. Some factors, such as pathology of the peripheral nerves, large or edematous extremities, distance of the electrodes to the underlying nerves, types of stimulating electrodes, may limit the effectiveness of stimulation. A stimulus of 50mA or greater is required sometimes. There is concern of tissue damage from high current densities at the stimulation site which is rare.&lt;br /&gt;
&lt;br /&gt;
== Recording Techniques ==&lt;br /&gt;
&lt;br /&gt;
#&#039;&#039;&#039;Electrodes&#039;&#039;&#039;: Metal surface cup electrodes are non-invasive electrodes, which can be applied with conductive gel after skin preparation. Subdermal needles are also commonly used in the operating room; some are available with angled or hooked tips. A corkscrew version can be screwed into the scalp for prolonged recording, however excessive bleeding can be a concern. For direct cortical mapping and recording, a strip or grid electrode array can be used for cranial surgeries. &lt;br /&gt;
#&#039;&#039;&#039;Recording Sites&#039;&#039;&#039;&lt;br /&gt;
##Cortical recording of upper extremity SSEP: It is the post-central gyrus of somatosensory cortex, contralateral to the stimulated limb. The locations are called CP3 and CP4 which are 2 cm posterior to the C3 and C4 positions of the 10-20 International System of EEG electrode placement. The recording montage can be CP3-Fz or CP3-CP4 for right arm stimulation; CP4-Fz or CP4-CP3 for left arm stimulation.&lt;br /&gt;
##Cortical recording of lower extremity SSEP: CPz is the active electrode site, which is 2 cm posterior to Cz. The traditional derivation of recording is CPz-Fz; however it should not be the only standard recording derivation, according to studies for optimized lower extremity SSEP recording by MacDonald DB et al and many others. Often time CPz-CPc (which is CPz-CP4 for left leg stimulation, and CPz-CP3 for right) may produce higher amplitude and more reliable signals.&lt;br /&gt;
##Subcortical: The recording can be made at posterior cervical spine, one or linked earlobes, or mastoid. Subcortical responses are less affected by inhalational agents. However, the subcortical SSEP response is normally very well defined for upper extremity stimulation, it is often poorly defined for lower extremity stimulation.&lt;br /&gt;
##Peripheral nerve: Usually it is the ipsilateral Erb&#039;s point for upper extremity stimulation, and ipsilateral popliteal fossa for lower extremity stimulation. This is done to verify the status of the peripheral stimulation.&lt;br /&gt;
#&#039;&#039;&#039;Averaging:&#039;&#039;&#039; The SSEP amplitudes tend to be low; as high as only several microvolts, or as low as less than a microvolts especially with pathological subjects. Averaging is required to record the signal against biological and ambient noise. SSEP signal is time-locked to the stimulus and most of the noise occurs randomly, allowing the noise to be averaged out with averaging of repeated responses. Some earlier guidelines such as that from American EEG Society suggested acquiring 500-2000 trails per averaged response. However for surgical monitoring well defined evoked potentials should be acquired as quickly as possible. With good preparation of the recording sites to reduce impedance, and optimized recording montages, clean signals could be recorded as few as 50-200 trials. &lt;br /&gt;
#&#039;&#039;&#039;Recording Parameters&#039;&#039;&#039;&lt;br /&gt;
##Filters: More environmental noise in the operating room and necessity of quick acquisition make it important to choose optimal filter settings, different from laboratory SSEP diagnostic studies. The majority of the energy contained in cortical SSEP is present in the frequency bandpass above 30Hz and below 500Hz; filters can be set to (10-30) Hz to (250-1000) Hz. The relative frequency content of the subcortical or peripheral responses is much higher, thus the filters can be set to (30-100)Hz to (500-2000) Hz.&lt;br /&gt;
##Timebase: The timebase is usually set at 50 milliseconds for upper extremity SSEPs, and 100 milliseconds for upper extremity SSEPs. It is based on the normal conduction time between the stimulation and recording sites. It may need adjustment depending on the age and size of the individual, and any pathological conditions.&lt;br /&gt;
##Sensitivity: The median amplitude of SSEP is about 1 microvolt. The recording sensitivity could range from 0.1 to 5 microvolts/unit. With direct cortical recording during cranial surgeries, the amplitude can be high and the sensitivity my be set to 20-50 microvolts/unit.&lt;br /&gt;
##Sweep delay: Normally it should be avoided to use sweep delay. However it may be necessary when large stimulus artifact is present.&lt;br /&gt;
##Interleaving recording: Alternating recording of SSEP responses to stimulation of 2 or 4 limbs at the same time is available with modern recording devices from different manufacturers.&lt;br /&gt;
&lt;br /&gt;
== Waveforms ==&lt;br /&gt;
&#039;&#039;&#039;Upper Extremity SSEPs&#039;&#039;&#039;&lt;br /&gt;
#N9: Recorded from ipsilateral Erb&#039;s point, and sometimes it&#039;s called EP. It is a compound action potential from the axons to the median nerve or ulnar nerve stimulation.&lt;br /&gt;
#N13-P14: Cervical potentials, recorded near C5 spinal process. The origin is thought to be dorsal horn neurons, and the caudal medial lemniscus.&lt;br /&gt;
#N20-P23: Scalp potentials, generated from the thalamocortical radiations.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Lower Extremity SSEPs&#039;&#039;&#039;&lt;br /&gt;
#LP: Recorded from the T12 spinal process, arise from the afferent nerve volley in the dorsal roots and dorsal root entry zone.&lt;br /&gt;
#N34: Recorded at the cervical spine; the amplitude can be very low and difficult to identify. The origin is thought to be brainstem or perhaps thalamus.&lt;br /&gt;
#P37-N45: Scalp potentials, reflect activation of the primary somatosensory cortex.&lt;br /&gt;
&lt;br /&gt;
[[Image:SSEP Waveforms.jpg|center|2000px|750px]]&lt;br /&gt;
&lt;br /&gt;
== Intraoperative Monitoring ==&lt;br /&gt;
The basic principle of intraoperative monitoring with mixed nerve SSEP is to stimulate nerves distal to the surgical site, and to record responses proximal to the surgical site. In most cases, these recording sites should include one cortical and one subcortical recording site.&lt;br /&gt;
&lt;br /&gt;
#&#039;&#039;&#039;Data acquisition&#039;&#039;&#039;: Baseline SSEP responses should be established, ideally after induction and before patient positioning and surgical incision. Data should be collected throughout the surgical procedure, with corresponding documentation of surgical events such as incision, exposure, decompression, instrumentation, closure, etc. In addition, relevant physiological variables such as blood pressure and temperature changes, anesthetic agents being used and the levels, significant signal changes during the surgery and any communication and interventions should be documented.&lt;br /&gt;
#&#039;&#039;&#039;Alert criteria&#039;&#039;&#039;: Significant signal changes, with 50% decrease of peak to peak amplitude and 10% increase of latency, may be indication of nervous system functional changes and should be reported to the operating surgeon, and call for possible intervention.&lt;br /&gt;
&lt;br /&gt;
Depending on the specific surgery, planing is required to monitor the part of the nervous system at risk.&lt;br /&gt;
#&#039;&#039;&#039;Peripheral nerve and plexus&#039;&#039;&#039;&lt;br /&gt;
#&#039;&#039;&#039;Spinal nerve root&#039;&#039;&#039;&lt;br /&gt;
#&#039;&#039;&#039;Spinal cord&#039;&#039;&#039;&lt;br /&gt;
#&#039;&#039;&#039;Brainstem and thalamus&#039;&#039;&#039;&lt;br /&gt;
#&#039;&#039;&#039;Brain&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
== Systemic and Anesthesia Factors ==&lt;br /&gt;
#&#039;&#039;&#039;Temperature&#039;&#039;&#039;&lt;br /&gt;
#&#039;&#039;&#039;Blood pressure&#039;&#039;&#039;&lt;br /&gt;
#&#039;&#039;&#039;Halogenated inhalational agents&#039;&#039;&#039;&lt;br /&gt;
#&#039;&#039;&#039;Nitrous oxide&#039;&#039;&#039;&lt;br /&gt;
#&#039;&#039;&#039;Intravenous analgesic agents&#039;&#039;&#039;&lt;br /&gt;
#&#039;&#039;&#039;Muscle relaxants&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
==References==&lt;br /&gt;
# Brown RH, Nash CL, Berilla JA, Amaddio MD. Cortical evoked potential monitoring. A system for intraoperative monitoring of spinal cord function. Spine 1984; 9: 256-261.&lt;br /&gt;
# Celesia GG. Somatosensory evoked potentials recorded directly from human thalamus and Sm I cortical area. Arch Neurol 1979; 36: 399-405.&lt;br /&gt;
# Cohen AR, Young W, Ransohoff J. Intraspinal localization of the somatosensory evoked potential. Neurosurgery 1981; 9: 157-62.&lt;br /&gt;
# Kelly DL Jr, Goldring S, O’Leary JL. Averaged evoked somatosensory responses from exposed cortex of man. Arch Neurol 1965; 13: 1-9.&lt;br /&gt;
# Larson SJ, Sances A. Evoked potentials in man: neurosurgical applications. Am J Surg 1966; 111: 857-861.&lt;br /&gt;
# MacDonald DB. Individually optimizing posterior tibial somatosensory evoked potential P37 scalp derivations for intraoperative monitoring. J Clin Neurophysiol. 2001 Jul;18(4):364-71.&lt;br /&gt;
# Mauguiere F. Anatomic origin of the cervical N13 potential evoked by upper extremity stimulation. J of Clin Neurophysiology 2000; 17: 236-245.&lt;br /&gt;
# McCallum JE, Bennett MH. Electrophysiologic monitoring of spinal cord function during intraspinal surgery. Surg Forum 1975; 26: 469-471.&lt;br /&gt;
# Nash CL, Long RA, Schatzinger LA, Brown RH. Spinal cord monitoring during operative treatment of the spine. Clin Orthop 1977; 126: 100-105.&lt;br /&gt;
# Nuwer MR, Dawson E. Intraoperative evoked potential monitoring of the spinal cord: enhanced stability of cortical recordings. Electroenceph Clin Neurophysiol 1984; 59: 318-24.&lt;br /&gt;
# Nuwer MR, Dawson EG, Carlson LG, Kanim LEA, Sherman JE. Somatosensory evoked potential spinal cord monitoring reduces neurologic deficits after scoliosis surgery: results of a large multicenter survey. Electroencepholog and Clin Neurophysiol 1995; 96: 6-11.&lt;br /&gt;
# Nuwer MR, et al. IFCN recommended standards for short latency somatosensory evoked potentials. Report of an IFCN committee. Electroencephalography and Clinical Neurophysiology 1994; 91: 6-11.&lt;br /&gt;
# Powers SK, Bolger CA, Edwards MSB. Spinal cord pathways mediating somatosensory evoked potentials. J Neurosurg 1982; 57: 472-82.&lt;br /&gt;
# Simpson RK JR, Blackburn JG, Martin HF III, Katz S. Peripheral nerve fibers and spinal cord pathway contribution to the somatosensory evoked potentials. Exp Neurol 1981; 73: 700-15.&lt;br /&gt;
# Sloan TB. Anesthetic Effects on Electrophysiologic Recordings. Journal of Clinical Neurophysiology 1998; 15: 217-226.&lt;br /&gt;
# Toleikis JR. Intraoperative monitoring using somatosensory evoked potentials: A position statement by the American Society of Neurophysiological Monitoring. J Clin Monit Comput. 2005; 19(3):241-58.&lt;br /&gt;
# Wang BP, Turner LA, Kamp AM, Venier LH. CPz-CP4 and CPz-CP3 are superior to CPz-FPz for recording left and right tibial nerve somatosensory evoked potentials for intraoperative monitoring. A review study in 264 patients. 2006 The 17th Annual Meeting of American Society of Neurophysiological Monitoring.&lt;br /&gt;
# Yanni DS, Ulkatan S, Deletis V, Barrenechea IJ, Sen C, Perin NI. Utility of neurophysiological monitoring using dorsal column mapping in intramedullary spinal cord surgery. J Neurosurg Spine. 2010;12:623-628.&lt;br /&gt;
# York DH, Chabot RJ, Gaines RW. Response variability of somatosensory evoked potentials during scoliosis surgery. Spine 1987; 12: 864-876.&lt;/div&gt;</summary>
		<author><name>Bpw</name></author>
	</entry>
	<entry>
		<id>https://neurophys.org/wiki/index.php?title=Somatosensory_Evoked_Potentials_(SSEP)&amp;diff=147</id>
		<title>Somatosensory Evoked Potentials (SSEP)</title>
		<link rel="alternate" type="text/html" href="https://neurophys.org/wiki/index.php?title=Somatosensory_Evoked_Potentials_(SSEP)&amp;diff=147"/>
		<updated>2013-11-04T16:33:19Z</updated>

		<summary type="html">&lt;p&gt;Bpw: /* References */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Somatosensory evoked potentials (SSEP) are recorded from the central nervous system following stimulation of peripheral nerves.&lt;br /&gt;
&lt;br /&gt;
== Introduction==&lt;br /&gt;
&lt;br /&gt;
Somatosensory Evoked Potentials (SSEPs) are electric signals recorded from the scalp or spine following stimulation to the peripheral nerves. They are time-locked responses, representing the function of the ascending sensory pathways. Early in the 1960s Larson et al introduced the use of somatosensory evoked potentials to monitor neural structure during neurosurgical procedures. It was utilized as a supplement to the wake-up test during correctional spinal surgeries for spinal deformities such as scoliosis to provide warning of compromised spinal cord function to the spine surgeons, as reported by McCallum et al and Nash et al in the 1970s. Since then SSEP has become one of the earliest and primary tools for intraoperative neurophysiological monitoring.&lt;br /&gt;
&lt;br /&gt;
== Somatosensory Pathways ==&lt;br /&gt;
[[Image:Ascending Pathways.jpg|right|100px|200px]]&lt;br /&gt;
&lt;br /&gt;
Distal peripheral nerves are stimulated for SSEP recordings; typically the median or ulnar nerve at the wrist for upper extremity SSEPs, or posterior tibial nerve at the ankle for lower extremity SSEPs. The ascending sensory volley enters the spinal cord through dorsal nerve roots. Multiple dorsal or posterior column spinal pathways such as the gracile fasciculus (legs and trunk) and the cuneate fasciculus (arms and trunk) mediate the SSEP responses. They arrive at the medulla and make synaptic connection at the medullary nuclei (nucleus cuneatus and nucleus gracilis). From there they cross and ascend in the medial lemniscal pathways to thalamic nuclei, which in turn project up to the somatosenory cortex.&lt;br /&gt;
&lt;br /&gt;
There is no synapses between the peripheral stimulation sites and the medullary nuclei. Synapses are the sites of action for inhalational anesthetic agents. Therefore any SSEP responses recorded below the level of medullary nuclei are affected only minimally by general anesthesia. The cortical SSEP responses, however, are greatly affected by inhalational agents; whichever recorded anesthetic management is very much required.&lt;br /&gt;
&lt;br /&gt;
== Stimulation ==&lt;br /&gt;
#&#039;&#039;&#039;Stimulation Sites&#039;&#039;&#039;: SSEPs may be elicited by electrical stimulation to major nerve trunks or dermatomes. Upper extremity mixed or major nerve SSEPs are typically obtained by stimulating the median nerve or ulnar nerve near the wrist; or sometimes the ulnar nerve at the elbow. Lower extremity SSEPs are normally recorded to stimulation of the posterior tibial nerve at the ankle, or peroneal nerve near the head of the fibula at the knee. Usually the anode electrode should be placed 2-4 cm distal to the cathode electrode to avoid anodal block.&lt;br /&gt;
#&#039;&#039;&#039;Electrodes&#039;&#039;&#039;: Subdermal needle electrodes or adhesive surface electrodes are most commonly used for intraoperative SSEP recordings. Some other types of electrodes such as bar electrodes and EEG metal disc electrodes are more suitable for diagnostic SSEP recordings in the lab. Needle electrodes can be placed closer to the underlying nerves than surface electrodes; however they are associated with additional risks of infection, bleeding, and inadvertent needle sticks.&lt;br /&gt;
#&#039;&#039;&#039;Constant Current vs Constant Voltage&#039;&#039;&#039;: Constant current stimulation is recommended for consistent and reliable stimulation for optimal SSEP recording in the OR, especially for long surgical procedures. Constant current stimuli may compensate for any changes in electrical conductivity, or electrode contact resistance.&lt;br /&gt;
#&#039;&#039;&#039;Stimulation Parameters&#039;&#039;&#039;: a series of rectangular pulses with certain pulse width and frequency are typically used as electrical stimuli for SSEP recording. &lt;br /&gt;
##&#039;&#039;&#039;Pulse width (or pulse duration)&#039;&#039;&#039;: 200-300 microsecond is suggested  &lt;br /&gt;
##&#039;&#039;&#039;Frequency (or rep rate)&#039;&#039;&#039;: Higher stimulus rate is desired for quick acquisition of SSEP responses in the operating room. However increasing the rate too high may result in degradation of the responses; also it is limited when interleaving stimulation of 2 or 4 limbs. In general a frequency between 2 and 5 Hz are recommended. To avoid synchronization between the responses and the underlying electrical noise, most commonly 60Hz or 50Hz in different countries, the stimulus rate should not be a submultiple of the noise frequency. Sometimes a slight change of stimulus rate, for example from 4.80 to 4.13, may improve the quality of the evoked responses.&lt;br /&gt;
##&#039;&#039;&#039;Intensity&#039;&#039;&#039;: Supramaximal stimulation should be used to produce repeatable responses. Some factors, such as pathology of the peripheral nerves, large or edematous extremities, distance of the electrodes to the underlying nerves, types of stimulating electrodes, may limit the effectiveness of stimulation. A stimulus of 50mA or greater is required sometimes. There is concern of tissue damage from high current densities at the stimulation site which is rare.&lt;br /&gt;
&lt;br /&gt;
== Recording Techniques ==&lt;br /&gt;
&lt;br /&gt;
#&#039;&#039;&#039;Electrodes&#039;&#039;&#039;: Metal surface cup electrodes are non-invasive electrodes, which can be applied with conductive gel after skin preparation. Subdermal needles are also commonly used in the operating room; some are available with angled or hooked tips. A corkscrew version can be screwed into the scalp for prolonged recording, however excessive bleeding can be a concern. For direct cortical mapping and recording, a strip or grid electrode array can be used for cranial surgeries. &lt;br /&gt;
#&#039;&#039;&#039;Recording Sites&#039;&#039;&#039;&lt;br /&gt;
##Cortical recording of upper extremity SSEP: It is the post-central gyrus of somatosensory cortex, contralateral to the stimulated limb. The locations are called CP3 and CP4 which are 2 cm posterior to the C3 and C4 positions of the 10-20 International System of EEG electrode placement. The recording montage can be CP3-Fz or CP3-CP4 for right arm stimulation; CP4-Fz or CP4-CP3 for left arm stimulation.&lt;br /&gt;
##Cortical recording of lower extremity SSEP: CPz is the active electrode site, which is 2 cm posterior to Cz. The traditional derivation of recording is CPz-Fz; however it should not be the only standard recording derivation, according to studies for optimized lower extremity SSEP recording by MacDonald DB et al and many others. Often time CPz-CPc (which is CPz-CP4 for left leg stimulation, and CPz-CP3 for right) may produce higher amplitude and more reliable signals.&lt;br /&gt;
##Subcortical: The recording can be made at posterior cervical spine, one or linked earlobes, or mastoid. Subcortical responses are less affected by inhalational agents. However, the subcortical SSEP response is normally very well defined for upper extremity stimulation, it is often poorly defined for lower extremity stimulation.&lt;br /&gt;
##Peripheral nerve: Usually it is the ipsilateral Erb&#039;s point for upper extremity stimulation, and ipsilateral popliteal fossa for lower extremity stimulation. This is done to verify the status of the peripheral stimulation.&lt;br /&gt;
#&#039;&#039;&#039;Averaging:&#039;&#039;&#039; The SSEP amplitudes tend to be low; as high as only several microvolts, or as low as less than a microvolts especially with pathological subjects. Averaging is required to record the signal against biological and ambient noise. SSEP signal is time-locked to the stimulus and most of the noise occurs randomly, allowing the noise to be averaged out with averaging of repeated responses. Some earlier guidelines such as that from American EEG Society suggested acquiring 500-2000 trails per averaged response. However for surgical monitoring well defined evoked potentials should be acquired as quickly as possible. With good preparation of the recording sites to reduce impedance, and optimized recording montages, clean signals could be recorded as few as 50-200 trials. &lt;br /&gt;
#&#039;&#039;&#039;Recording Parameters&#039;&#039;&#039;&lt;br /&gt;
##Filters: More environmental noise in the operating room and necessity of quick acquisition make it important to choose optimal filter settings, different from laboratory SSEP diagnostic studies. The majority of the energy contained in cortical SSEP is present in the frequency bandpass above 30Hz and below 500Hz; filters can be set to (10-30) Hz to (250-1000) Hz. The relative frequency content of the subcortical or peripheral responses is much higher, thus the filters can be set to (30-100)Hz to (500-2000) Hz.&lt;br /&gt;
##Timebase: The timebase is usually set at 50 milliseconds for upper extremity SSEPs, and 100 milliseconds for upper extremity SSEPs. It is based on the normal conduction time between the stimulation and recording sites. It may need adjustment depending on the age and size of the individual, and any pathological conditions.&lt;br /&gt;
##Sensitivity: The median amplitude of SSEP is about 1 microvolt. The recording sensitivity could range from 0.1 to 5 microvolts/unit. With direct cortical recording during cranial surgeries, the amplitude can be high and the sensitivity my be set to 20-50 microvolts/unit.&lt;br /&gt;
##Sweep delay: Normally it should be avoided to use sweep delay. However it may be necessary when large stimulus artifact is present.&lt;br /&gt;
##Interleaving recording: Alternating recording of SSEP responses to stimulation of 2 or 4 limbs at the same time is available with modern recording devices from different manufacturers.&lt;br /&gt;
&lt;br /&gt;
== Waveforms ==&lt;br /&gt;
&#039;&#039;&#039;Upper Extremity SSEPs&#039;&#039;&#039;&lt;br /&gt;
#N9: Recorded from ipsilateral Erb&#039;s point, and sometimes it&#039;s called EP. It is a compound action potential from the axons to the median nerve or ulnar nerve stimulation.&lt;br /&gt;
#N13-P14: Cervical potentials, recorded near C5 spinal process. The origin is thought to be dorsal horn neurons, and the caudal medial lemniscus.&lt;br /&gt;
#N20-P23: Scalp potentials, generated from the thalamocortical radiations.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Lower Extremity SSEPs&#039;&#039;&#039;&lt;br /&gt;
#LP: Recorded from the T12 spinal process, arise from the afferent nerve volley in the dorsal roots and dorsal root entry zone.&lt;br /&gt;
#N34: Recorded at the cervical spine; the amplitude can be very low and difficult to identify. The origin is thought to be brainstem or perhaps thalamus.&lt;br /&gt;
#P37-N45: Scalp potentials, reflect activation of the primary somatosensory cortex.&lt;br /&gt;
&lt;br /&gt;
[[Image:SSEP Waveforms.jpg|center|2000px|750px]]&lt;br /&gt;
&lt;br /&gt;
== Intraoperative Monitoring ==&lt;br /&gt;
The basic principle of intraoperative monitoring with mixed nerve SSEP is to stimulate nerves distal to the surgical site, and to record responses proximal to the surgical site. In most cases, these recording sites should include one cortical and one subcortical recording site.&lt;br /&gt;
&lt;br /&gt;
#&#039;&#039;&#039;Data acquisition&#039;&#039;&#039;: Baseline SSEP responses should be established, ideally after induction and before patient positioning and surgical incision. Data should be collected throughout the surgical procedure, with corresponding documentation of surgical events such as incision, exposure, decompression, instrumentation, closure, etc. In addition, relevant physiological variables such as blood pressure and temperature changes, anesthetic agents being used and the levels, significant signal changes during the surgery and any communication and interventions should be documented.&lt;br /&gt;
#&#039;&#039;&#039;Alert criteria&#039;&#039;&#039;: Significant signal changes, with 50% decrease of peak to peak amplitude and 10% increase of latency, may be indication of nervous system functional changes and should be reported to the operating surgeon, and call for possible intervention.&lt;br /&gt;
&lt;br /&gt;
Depending on the specific surgery, planing is required to monitor the part of the nervous system at risk.&lt;br /&gt;
#&#039;&#039;&#039;Peripheral nerve and plexus&#039;&#039;&#039;&lt;br /&gt;
#&#039;&#039;&#039;Spinal nerve root&#039;&#039;&#039;&lt;br /&gt;
#&#039;&#039;&#039;Spinal cord&#039;&#039;&#039;&lt;br /&gt;
#&#039;&#039;&#039;Brainstem and thalamus&#039;&#039;&#039;&lt;br /&gt;
#&#039;&#039;&#039;Brain&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
== Systemic and Anesthesia Factors ==&lt;br /&gt;
#&#039;&#039;&#039;Temperature&#039;&#039;&#039;&lt;br /&gt;
#&#039;&#039;&#039;Blood pressure&#039;&#039;&#039;&lt;br /&gt;
#&#039;&#039;&#039;Halogenated inhalational agents&#039;&#039;&#039;&lt;br /&gt;
#&#039;&#039;&#039;Nitrous oxide&#039;&#039;&#039;&lt;br /&gt;
#&#039;&#039;&#039;Intravenous analgesic agents&#039;&#039;&#039;&lt;br /&gt;
#&#039;&#039;&#039;Muscle relaxants&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
==References==&lt;br /&gt;
# Celesia GG. Somatosensory evoked potentials recorded directly from human thalamus and Sm I cortical area. Arch Neurol 1979; 36: 399-405.&lt;br /&gt;
# Cohen AR, Young W, Ransohoff J. Intraspinal localization of the somatosensory evoked potential. Neurosurgery 1981; 9: 157-62.&lt;br /&gt;
# Kelly DL Jr, Goldring S, O’Leary JL. Averaged evoked somatosensory responses from exposed cortex of man. Arch Neurol 1965; 13: 1-9.&lt;br /&gt;
# Larson SJ, Sances A. Evoked potentials in man: neurosurgical applications. Am J Surg 1966; 111: 857-861.&lt;br /&gt;
# MacDonald DB. Individually optimizing posterior tibial somatosensory evoked potential P37 scalp derivations for intraoperative monitoring. J Clin Neurophysiol. 2001 Jul;18(4):364-71.&lt;br /&gt;
# Mauguiere F. Anatomic origin of the cervical N13 potential evoked by upper extremity stimulation. J of Clin Neurophysiology 2000; 17: 236-245.&lt;br /&gt;
# McCallum JE, Bennett MH. Electrophysiologic monitoring of spinal cord function during intraspinal surgery. Surg Forum 1975; 26: 469-471.&lt;br /&gt;
# Nash CL, Long RA, Schatzinger LA, Brown RH. Spinal cord monitoring during operative treatment of the spine. Clin Orthop 1977; 126: 100-105.&lt;br /&gt;
# Nuwer MR, Dawson E. Intraoperative evoked potential monitoring of the spinal cord: enhanced stability of cortical recordings. Electroenceph Clin Neurophysiol 1984; 59: 318-24.&lt;br /&gt;
# Nuwer MR, et al. IFCN recommended standards for short latency somatosensory evoked potentials. Report of an IFCN committee. Electroencephalography and Clinical Neurophysiology 1994; 91: 6-11.&lt;br /&gt;
# Powers SK, Bolger CA, Edwards MSB. Spinal cord pathways mediating somatosensory evoked potentials. J Neurosurg 1982; 57: 472-82.&lt;br /&gt;
# Simpson RK JR, Blackburn JG, Martin HF III, Katz S. Peripheral nerve fibers and spinal cord pathway contribution to the somatosensory evoked potentials. Exp Neurol 1981; 73: 700-15.&lt;br /&gt;
# Sloan TB. Anesthetic Effects on Electrophysiologic Recordings. Journal of Clinical Neurophysiology 1998; 15: 217-226.&lt;br /&gt;
# Toleikis JR. Intraoperative monitoring using somatosensory evoked potentials: A position statement by the American Society of Neurophysiological Monitoring. J Clin Monit Comput. 2005; 19(3):241-58.&lt;br /&gt;
# Wang BP, Turner LA, Kamp AM, Venier LH. CPz-CP4 and CPz-CP3 are superior to CPz-FPz for recording left and right tibial nerve somatosensory evoked potentials for intraoperative monitoring. A review study in 264 patients. 2006 The 17th Annual Meeting of American Society of Neurophysiological Monitoring.&lt;/div&gt;</summary>